Liwen Xu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Liwen Xu has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Xingwang Liu
College of Urban and Rural Construction, Hebei Agricultural University, Baoding 071001, China
2 shared publications - Yang Liu
Department of Civil Engineering, Tianjin University, Tianjin 300072, China
2 shared publications - Fan Liu
College of Urban and Rural Construction, Hebei Agricultural University, Baoding 071001, China
1 shared publication - Hongtao Li
Department of Civil Engineering, Tianjin University, Tianjin 300072, China
1 shared publication - Qingkai Meng
College of Urban and Rural Construction, Hebei Agricultural University, Baoding 071001, China
1 shared publication - Wenya Sun
College of Urban and Rural Construction, Hebei Agricultural University, Baoding 071001, China
1 shared publication
Latest Publications
- Open Access
Study on the Bending Performance of Connection Joints in a New Type of Modular Steel Structure Emergency Repair Pier
The pier-type repair equipment for bridges is a crucial branch of bridge emergency repair. However, the existing bridge pier repair equipment predominantly utilizes rod systems, which require substantial assembly work, hindering the rapid restoration of damaged bridges. Modular steel structure buildings, as a highly integrated form of prefabricated construction, can play a significant role in emergency rescue operations. Based on the modular architectural design concept, this paper proposes a new type of modular steel structure emergency repair pier joint that facilitates rapid assembly and connection between modular units. Using ABAQUS 2022 software to establish a finite element model of the joint, the bending performance under lateral displacement loads perpendicular to the joint opening direction (X-direction in the model coordinate system) and parallel to the joint opening direction (Z-direction in the model coordinate system) is analyzed. The influence of the width-to-thickness ratio of the upper corner piece base plate D/t1 (where D is the width of the upper corner piece base plate and t1 is the thickness of the upper corner plate), the height-to-thickness ratio of the lower corner piece top plate h/t2 (where h is the height of the protrusion of the lower corner piece and t2 is the thickness of the lower corner piece top plate), the height of the protrusion of the lower corner piece (h), and the bolt diameter (d) on the bending performance of the joint is investigated. Recommendations for the design values of the joint are provided. Then, the flexural behavior of the joint under 0.1, 0.2, and 0.3 axial compression ratios is studied, respectively. The results show that with the increase of axial compression ratio, the yield rotation angle and ultimate rotation angle of the joint decrease, and the bearing capacity decreases faster after the joint reaches the ultimate bearing capacity. When the joint is subjected to the X-direction horizontal lateral displacement load, the initial flexural stiffness and flexural capacity of the joint increase with an increase in the axial compression ratio. When subjected to the horizontal lateral displacement load in the Z-direction, the initial bending stiffness of the joint increases with an increase in the axial compression ratio, and the bending capacity does not change much. In addition, the joint is classified; from the perspective of load-bearing capacity, it is a partially resistant joint, and from the perspective of stiffness, it is a semi-rigid joint. Finally, a simplified calculation model for the joint is proposed based on the component method.
Open AccessStudy on the Bending Performance of Connection Joints in a New Type of Modular Steel Structure Emergency Repair Pier
The pier-type repair equipment for bridges is a crucial branch of bridge emergency repair. However, the existing bridge pier repair equipment predominantly utilizes rod systems, which require substantial assembly work, hindering the rapid restoration of damaged bridges. Modular steel structure buildings, as a highly integrated form of prefabricated construction, can play a significant role in emergency rescue operations. Based on the modular architectural design concept, this paper proposes a new type of modular steel structure emergency repair pier joint that facilitates rapid assembly and connection between modular units. Using ABAQUS 2022 software to establish a finite element model of the joint, the bending performance under lateral displacement loads perpendicular to the joint opening direction (X-direction in the model coordinate system) and parallel to the joint opening direction (Z-direction in the model coordinate system) is analyzed. The influence of the width-to-thickness ratio of the upper corner piece base plate D/t1 (where D is the width of the upper corner piece base plate and t1 is the thickness of the upper corner plate), the height-to-thickness ratio of the lower corner piece top plate h/t2 (where h is the height of the protrusion of the lower corner piece and t2 is the thickness of the lower corner piece top plate), the height of the protrusion of the lower corner piece (h), and the bolt diameter (d) on the bending performance of the joint is investigated. Recommendations for the design values of the joint are provided. Then, the flexural behavior of the joint under 0.1, 0.2, and 0.3 axial compression ratios is studied, respectively. The results show that with the increase of axial compression ratio, the yield rotation angle and ultimate rotation angle of the joint decrease, and the bearing capacity decreases faster after the joint reaches the ultimate bearing capacity. When the joint is subjected to the X-direction horizontal lateral displacement load, the initial flexural stiffness and flexural capacity of the joint increase with an increase in the axial compression ratio. When subjected to the horizontal lateral displacement load in the Z-direction, the initial bending stiffness of the joint increases with an increase in the axial compression ratio, and the bending capacity does not change much. In addition, the joint is classified; from the perspective of load-bearing capacity, it is a partially resistant joint, and from the perspective of stiffness, it is a semi-rigid joint. Finally, a simplified calculation model for the joint is proposed based on the component method.
- Open Access
Modular Steel Buildings Based on Self-Locking-Unlockable Connections Seismic Performance Analysis
This paper introduces a new self-locking-unlockable modular building with an inter-module connection, and its seismic performance is investigated. The new connection can realize fast connection and unlocking during construction through exceptional design. In this paper, taking the Tianjin Binhai Apartment project as the background, for the actual force situation of the new connection, considering the influence of corrugated steel plate stiffness, a simplified model of the connection is constructed by using multi-fold elastic connection, and the corrugated steel plate stiffness is simulated with equivalent support. In the MIDAS Gen 2021 software, the five-story and six-story structural models using traditional rigid connections and new connections were established, respectively, and reaction spectrum analysis was carried out. Meanwhile, seismic waves that comply with codes were selected for dynamic time course analysis. The results show that the stress ratios of all components of the new connection model and the traditional rigid model are less than 1. Among them, the maximum stress ratios of both floor beams are 0.745 and 0.725, respectively; the maximum stress ratios of the modular columns are 0.655 and 0.494, respectively; the stress ratios of the ceiling beams are all less than 0.5; and the two models show good strength and stiffness reserves, following the design principle of strong columns and weak beams and verifying the reliability of the new connection model. Meanwhile, it is found that the inter-story displacement angle of the six-story structure with the new connections is less than the normative value under the action of rare earthquakes, and the difference in top displacement is about 18% compared with that of the rigid structure, so it is suggested that the new connections can be applied within the height of six stories.
Open AccessModular Steel Buildings Based on Self-Locking-Unlockable Connections Seismic Performance Analysis
This paper introduces a new self-locking-unlockable modular building with an inter-module connection, and its seismic performance is investigated. The new connection can realize fast connection and unlocking during construction through exceptional design. In this paper, taking the Tianjin Binhai Apartment project as the background, for the actual force situation of the new connection, considering the influence of corrugated steel plate stiffness, a simplified model of the connection is constructed by using multi-fold elastic connection, and the corrugated steel plate stiffness is simulated with equivalent support. In the MIDAS Gen 2021 software, the five-story and six-story structural models using traditional rigid connections and new connections were established, respectively, and reaction spectrum analysis was carried out. Meanwhile, seismic waves that comply with codes were selected for dynamic time course analysis. The results show that the stress ratios of all components of the new connection model and the traditional rigid model are less than 1. Among them, the maximum stress ratios of both floor beams are 0.745 and 0.725, respectively; the maximum stress ratios of the modular columns are 0.655 and 0.494, respectively; the stress ratios of the ceiling beams are all less than 0.5; and the two models show good strength and stiffness reserves, following the design principle of strong columns and weak beams and verifying the reliability of the new connection model. Meanwhile, it is found that the inter-story displacement angle of the six-story structure with the new connections is less than the normative value under the action of rare earthquakes, and the difference in top displacement is about 18% compared with that of the rigid structure, so it is suggested that the new connections can be applied within the height of six stories.