Sondes Guesmi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Sondes Guesmi has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Carlos A. Castilla-Martinez
Institut Européen des Membranes, IEM – UMR 5635, Univ Montpellier, ENSCM, CNRS, Montpellier, France
1 shared publication - Chama Mabrouk
Laboratory of Interfaces and Advanced Materials, University of Monastir, Faculty of Sciences of Monastir, Monastir 5000, Tunisia
1 shared publication - Fraj Echouchene
University of Sousse, Higher Institute of Applied Sciences and Technology of Sousse, Cité Ettafala, Ibn Khaldoun 4003, Sousse, Tunisia.
1 shared publication - Hamza Kahri
Laboratory of Interfaces and Advanced Materials, Faculty of Sciences, University of Monastir, 5019 Monastir, Tunisia
1 shared publication - Houcine Barhoumi
Laboratory of Interfaces and Advanced Materials, Faculty of Sciences of Monastir, University of Monastir, Monastir 5000, Tunisia
1 shared publication - Nadhem Missaoui
Laboratory of Interfaces and Advanced Materials, University of Monastir, Monastir 5000, Tunisia
1 shared publication
Latest Publications
- Open Access
High-Performance ZIF-7@PANI Electrochemical Sensor for Simultaneous Trace Cadmium and Lead Detection in Water Samples: A Box–Behnken Design Optimization Approach
This study presents the development of an innovative electrochemical sensor for the simultaneous detection of cadmium (Cd2+) and lead (Pb2+) ions in environmental samples. The sensor is developed based on a composite material of zeolite imidazolate framework ZIF-7 and polyaniline (PANI), referred to as ZIF-7@PANI, where ZIF-7 is rapidly synthesized at room temperature and polyaniline used to enhance the conductivity of the composite. Characterization via X-ray diffraction (DRX), scanning electron microscopy (SEM), and Fourier transform infrared spectroscopy (FTIR) confirmed successful synthesis. The composite was applied to a glassy carbon electrode (GCE) using drop-casting for heavy metal ion detection. Experimental parameters—including pH, incubation time, deposited quantity, and drying time—were optimized using the Box–Behnken design. Under optimal conditions, the ZIF-7@PANI/GCE sensor demonstrated a broad dynamic concentration range (0.002–1 µM for Pb2+ and 0.02–30 µM for Cd2+), with low detection limits (2.96 nM for Pb2+ and 10.6 nM for Cd2+). It also exhibited strong anti-interference properties and high recovery rates (85–110%), highlighting its potential for real practical applications.
Open AccessHigh-Performance ZIF-7@PANI Electrochemical Sensor for Simultaneous Trace Cadmium and Lead Detection in Water Samples: A Box–Behnken Design Optimization Approach
This study presents the development of an innovative electrochemical sensor for the simultaneous detection of cadmium (Cd2+) and lead (Pb2+) ions in environmental samples. The sensor is developed based on a composite material of zeolite imidazolate framework ZIF-7 and polyaniline (PANI), referred to as ZIF-7@PANI, where ZIF-7 is rapidly synthesized at room temperature and polyaniline used to enhance the conductivity of the composite. Characterization via X-ray diffraction (DRX), scanning electron microscopy (SEM), and Fourier transform infrared spectroscopy (FTIR) confirmed successful synthesis. The composite was applied to a glassy carbon electrode (GCE) using drop-casting for heavy metal ion detection. Experimental parameters—including pH, incubation time, deposited quantity, and drying time—were optimized using the Box–Behnken design. Under optimal conditions, the ZIF-7@PANI/GCE sensor demonstrated a broad dynamic concentration range (0.002–1 µM for Pb2+ and 0.02–30 µM for Cd2+), with low detection limits (2.96 nM for Pb2+ and 10.6 nM for Cd2+). It also exhibited strong anti-interference properties and high recovery rates (85–110%), highlighting its potential for real practical applications.