Adewale Adegboyega
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Adewale Adegboyega has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Saeed Sepasi
Hawaii Natural Energy Institute, University of Hawaii at Mnoa, Honolulu, HI, USA
3 shared publications - Abrar Shahriar Pramanik
Hawaii Natural Energy Institute, University of Hawaii at Mnoa, Honolulu, HI, USA
1 shared publication Brian Griswold
Hawaii Natural Energy Institute, University of Hawaii at Mnoa, Honolulu, HI, USA
1 shared publication- Brian Griswold
Hawai’i Natural Energy Institute, University of Hawai’i at Manoa, Honolulu, HI 96822, USA
1 shared publication - Harun Or Rashid Howlader
Hawai’i Natural Energy Institute, University of Hawai’i at Manoa, Honolulu, HI 96822, USA
1 shared publication - Leon Roose
Hawaii Natural Energy Institute, University of Hawaii at Manoa, Honolulu, HI 96822, USA
1 shared publication
Latest Publications
- Open Access
- 22 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 79833-79850
EMT-Based Sequence Analysis of a Converter-Dominated Microgrid Under Fault and Load Disturbances: Case Study of the NELHA Microgrid
Converter-dominated microgrids exhibit dynamic behaviors during faults and disturbances that differ fundamentally from those of synchronous-machine–dominated systems. This paper develops an electromagnetic transient (EMT) model of a converter-dominated microgrid and applies sequence-domain analysis based on instantaneous symmetrical components to evaluate its dynamic behavior under three scenarios: a single-line-to-ground (SLG) fault, a balanced three-phase short circuit, and a nonlinear load step. Both grid-connected and islanded operating modes are evaluated under matched disturbance types, locations, and timing, using mode-specific source configurations representative of actual microgrid operation. The simulations reveal a pronounced dependence on the operating mode. In grid-connected operation, the grid provides high fault currents, limits neutral shift, and enables rapid voltage recovery. In islanded mode, the effective positive- and zero-sequence impedances are higher, resulting in a reduced fault current, a pronounced zero-sequence voltage, and a larger neutral displacement. The time-domain post-processing clarifies the disturbance structure: SLG faults produce pronounced zero-sequence excursions and stronger phase asymmetry, whereas the 3ϕ faults remain phase-symmetric in the abc domain and are dominated by the positive-sequence response. The nonlinear load produces measurable asymmetry in the projected sequence quantities together with significant harmonic distortion in the currents. The EMT model captures early-cycle asymmetry, control-imposed current limiting, and sequence interactions that cannot be represented in phasor-domain root-mean-square (RMS) studies. These EMT-derived indicators provide grounding- and protection-relevant insights that can support grounding review, relay-sensitivity checks, and control assessment in converter-dominated microgrids.
- 22 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 79833-79850
Open AccessEMT-Based Sequence Analysis of a Converter-Dominated Microgrid Under Fault and Load Disturbances: Case Study of the NELHA Microgrid
Converter-dominated microgrids exhibit dynamic behaviors during faults and disturbances that differ fundamentally from those of synchronous-machine–dominated systems. This paper develops an electromagnetic transient (EMT) model of a converter-dominated microgrid and applies sequence-domain analysis based on instantaneous symmetrical components to evaluate its dynamic behavior under three scenarios: a single-line-to-ground (SLG) fault, a balanced three-phase short circuit, and a nonlinear load step. Both grid-connected and islanded operating modes are evaluated under matched disturbance types, locations, and timing, using mode-specific source configurations representative of actual microgrid operation. The simulations reveal a pronounced dependence on the operating mode. In grid-connected operation, the grid provides high fault currents, limits neutral shift, and enables rapid voltage recovery. In islanded mode, the effective positive- and zero-sequence impedances are higher, resulting in a reduced fault current, a pronounced zero-sequence voltage, and a larger neutral displacement. The time-domain post-processing clarifies the disturbance structure: SLG faults produce pronounced zero-sequence excursions and stronger phase asymmetry, whereas the 3ϕ faults remain phase-symmetric in the abc domain and are dominated by the positive-sequence response. The nonlinear load produces measurable asymmetry in the projected sequence quantities together with significant harmonic distortion in the currents. The EMT model captures early-cycle asymmetry, control-imposed current limiting, and sequence interactions that cannot be represented in phasor-domain root-mean-square (RMS) studies. These EMT-derived indicators provide grounding- and protection-relevant insights that can support grounding review, relay-sensitivity checks, and control assessment in converter-dominated microgrids.
- Open Access
- 12 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 83881-83896
Assessing Dynamic Behaviors in Converter- Dominated Power Systems via RMS and EMT Simulations: A Study of Hawaii’s NELHA Microgrid
The transition from conventional power systems to converter-based microgrids has significantly advanced sustainability, clean energy integration, and operational reliability. However, this paradigm shift introduces operational challenges due to the intermittent nature of renewable energy sources and the non-linear characteristics of power electronic loads, inducing voltage fluctuations and harmonic distortions that complicate voltage and frequency regulation. Accurate dynamic modeling is hypothesized to be critical for capturing such effects, enabling reliable simulation and control strategy development. This study introduces an innovative dynamic modeling framework for a real-world converter-based microgrid, utilizing both root mean square (RMS) and electromagnetic transient (EMT) simulation methods. The microgrid was modeled in DIgSILENT PowerFactory, with simulations calibrated against high-resolution field measurements from SEL-735 power quality meters. Results show that RMS simulations effectively characterize steady-state dynamics, while EMT simulations are essential for capturing high-frequency transients and non-linear effects from photovoltaic inverters and variable frequency drives (VFDs). This complementary approach provides a comprehensive understanding of microgrid behavior, providing critical insights for improving simulation accuracy, advancing protection schemes, and improving resilience in future low-inertia power networks.
- 12 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 83881-83896
Open AccessAssessing Dynamic Behaviors in Converter- Dominated Power Systems via RMS and EMT Simulations: A Study of Hawaii’s NELHA Microgrid
The transition from conventional power systems to converter-based microgrids has significantly advanced sustainability, clean energy integration, and operational reliability. However, this paradigm shift introduces operational challenges due to the intermittent nature of renewable energy sources and the non-linear characteristics of power electronic loads, inducing voltage fluctuations and harmonic distortions that complicate voltage and frequency regulation. Accurate dynamic modeling is hypothesized to be critical for capturing such effects, enabling reliable simulation and control strategy development. This study introduces an innovative dynamic modeling framework for a real-world converter-based microgrid, utilizing both root mean square (RMS) and electromagnetic transient (EMT) simulation methods. The microgrid was modeled in DIgSILENT PowerFactory, with simulations calibrated against high-resolution field measurements from SEL-735 power quality meters. Results show that RMS simulations effectively characterize steady-state dynamics, while EMT simulations are essential for capturing high-frequency transients and non-linear effects from photovoltaic inverters and variable frequency drives (VFDs). This complementary approach provides a comprehensive understanding of microgrid behavior, providing critical insights for improving simulation accuracy, advancing protection schemes, and improving resilience in future low-inertia power networks.
- Top Cited PapersOpen Access
DC Microgrid Deployments and Challenges: A Comprehensive Review of Academic and Corporate Implementations
DC microgrids are revolutionizing energy systems by offering efficient, reliable, and sustainable solutions to modern power grid challenges. By directly integrating renewable energy sources and eliminating the inefficiencies of AC-DC conversion, these systems simplify energy distribution and enhance performance in critical applications such as data centers, electric vehicle charging, and telecommunications. This review paper comprehensively examines the design, implementation, and performance of DC microgrids in real-world settings. Key components, including distributed energy resources (DERs), energy storage systems (ESSs), and control strategies, are analyzed to highlight their roles in ensuring reliability and operational efficiency. This review also explores the challenges facing DC microgrids, such as stability issues, protection mechanisms, and high initial costs, while offering insights into advanced control strategies and modular designs to overcome these obstacles. Through an evaluation of global case studies, this article bridges the gap between theoretical research and practical deployment and also demonstrates how DC microgrids can enhance energy efficiency, support sustainable power generation, and provide resilience in various applications. The findings highlight the potential of DC microgrids as a cornerstone of future energy systems, enabling clean, reliable, and decentralized energy solutions.
Top Cited PapersOpen AccessDC Microgrid Deployments and Challenges: A Comprehensive Review of Academic and Corporate Implementations
DC microgrids are revolutionizing energy systems by offering efficient, reliable, and sustainable solutions to modern power grid challenges. By directly integrating renewable energy sources and eliminating the inefficiencies of AC-DC conversion, these systems simplify energy distribution and enhance performance in critical applications such as data centers, electric vehicle charging, and telecommunications. This review paper comprehensively examines the design, implementation, and performance of DC microgrids in real-world settings. Key components, including distributed energy resources (DERs), energy storage systems (ESSs), and control strategies, are analyzed to highlight their roles in ensuring reliability and operational efficiency. This review also explores the challenges facing DC microgrids, such as stability issues, protection mechanisms, and high initial costs, while offering insights into advanced control strategies and modular designs to overcome these obstacles. Through an evaluation of global case studies, this article bridges the gap between theoretical research and practical deployment and also demonstrates how DC microgrids can enhance energy efficiency, support sustainable power generation, and provide resilience in various applications. The findings highlight the potential of DC microgrids as a cornerstone of future energy systems, enabling clean, reliable, and decentralized energy solutions.