Ishaan K. Singh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Ishaan K. Singh has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Bin Dong
James Tarpo Jr. and Margaret Tarpo Department of Chemistry, Purdue University, 560 Oval Dr., West Lafayette, Indiana 47907, United States
1 shared publication - Boyong Wan
Merck & Co., Inc
1 shared publication - Chi Zhang
Department of Chemistry, Purdue University, 560 Oval Dr., West Lafayette, IN 47907, USA
1 shared publication - Justin P. Lomont
Merck & Co., Inc., 126 East Lincoln Ave., P.O. Box 2000, Rahway, New Jersey 07065, United States
1 shared publication - Karsten J. Mohn
Purdue University West Lafayette
1 shared publication Shivam Mahapatra
Purdue University West Lafayette
1 shared publication
Latest Publications
- Open Access
- 21 February 2025
- Published by American Chemical Society (ACS) in ChemRxiv
Spontaneous or Stimulated? Investigating Raman’s Detection Limits in Aqueous Environments
Raman spectroscopy is a powerful method for analyzing chemical compositions across diverse samples. Spontaneous Raman scattering (spRS) provides complete Raman spectra but typically yields low signal levels, requiring long signal integration times. In contrast, stimulat-ed Raman scattering (SRS) produces much stronger signals, allowing for rapid spectral acquisition, and has been widely used to accelerate chemical imaging. Despite advances in both techniques, it remains unclear which method offers superior limits of detection (LODs) for molecules in biological samples. While theoretical comparisons under ideal conditions suggest that performance depends on photon flux and integration time, no experimental studies have directly compared the LOD of spRS and SRS spectroscopy. In this study, we systemati-cally compare the LOD of frequency-domain spRS and SRS for water-soluble analytes in aqueous solutions, a common environment for biological specimens. We first introduce a simplified LOD estimation methodology by taking only three measurements to derive the dilu-tion maximum (DM). This methodology achieved LOD estimates closely aligned with those obtained through serial dilution. Using this approach, we assessed the impact of various parameters, including Stokes laser power, the presence of beam scanning, number of pixels, and pixel dwell time, on the LOD of SRS spectroscopy and determined optimal conditions for SRS. Our results demonstrate that at short inte-gration times, SRS exhibits shot-noise-limited performance, with LOD inversely proportional to the square root of the acquisition time. At longer integration times, photothermal effects can cause deviations from ideal LOD scenarios. Under optimized experimental conditions, spectral-domain SRS confidently detects ~700 μM dimethyl sulfoxide in water and 1 g/L glucose and bovine serum albumin in aqueous solutions without spectral averaging. This performance can surpass that of spRS spectroscopy, even with equal or longer integration times.
- 21 February 2025
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessSpontaneous or Stimulated? Investigating Raman’s Detection Limits in Aqueous Environments
Raman spectroscopy is a powerful method for analyzing chemical compositions across diverse samples. Spontaneous Raman scattering (spRS) provides complete Raman spectra but typically yields low signal levels, requiring long signal integration times. In contrast, stimulat-ed Raman scattering (SRS) produces much stronger signals, allowing for rapid spectral acquisition, and has been widely used to accelerate chemical imaging. Despite advances in both techniques, it remains unclear which method offers superior limits of detection (LODs) for molecules in biological samples. While theoretical comparisons under ideal conditions suggest that performance depends on photon flux and integration time, no experimental studies have directly compared the LOD of spRS and SRS spectroscopy. In this study, we systemati-cally compare the LOD of frequency-domain spRS and SRS for water-soluble analytes in aqueous solutions, a common environment for biological specimens. We first introduce a simplified LOD estimation methodology by taking only three measurements to derive the dilu-tion maximum (DM). This methodology achieved LOD estimates closely aligned with those obtained through serial dilution. Using this approach, we assessed the impact of various parameters, including Stokes laser power, the presence of beam scanning, number of pixels, and pixel dwell time, on the LOD of SRS spectroscopy and determined optimal conditions for SRS. Our results demonstrate that at short inte-gration times, SRS exhibits shot-noise-limited performance, with LOD inversely proportional to the square root of the acquisition time. At longer integration times, photothermal effects can cause deviations from ideal LOD scenarios. Under optimized experimental conditions, spectral-domain SRS confidently detects ~700 μM dimethyl sulfoxide in water and 1 g/L glucose and bovine serum albumin in aqueous solutions without spectral averaging. This performance can surpass that of spRS spectroscopy, even with equal or longer integration times.