Masamichi Imai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Masamichi Imai has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Hiroshi Onishi
Department of Therapeutic Radiology, University of Yamanashi, Yamanashi, Japan
2 shared publications - Yoko Satoh
Imaging Center, Fujita Medical Innovation Center Tokyo, Tokyo, Japan
2 shared publications Chihiro Ikegawa
Yamanashi PET Imaging Clinic, Chuo City, Japan
1 shared publicationKazuaki Mori
Faculty of Radiology, Toranomon Hospital, Tokyo, Japan
1 shared publication- Kenichi Yokoyama
Department of Radiology, Faculty of Medicine, Kyorin University, Tokyo, Japan
1 shared publication - Kenji Hirata
Hokkaido University
1 shared publication
Latest Publications
- 19 September 2025
- Published by Springer Nature in Annals of Nuclear Medicine
- Vol. 40 (1) , 60-65
Impact of body weight on arterial partition coefficient estimation in 123I-IMP SPECT: a comparison between ARG and no-arterial sampling methods
Objective To evaluate the impact of body weight on the estimation of the arterial blood-to-whole-body partition coefficient in 123I-iodoamphetamine (IMP) SPECT using a no-arterial sampling method (validation method) and to compare it with the autoradiographic (ARG) method. Methods A total of 172 123I-IMP SPECT scans from clinical patients were retrospectively analyzed. To investigate systematic differences between the partition coefficients obtained by the ARG method and those estimated by the validation method in the QSPECT/DTARG package, a Bland–Altman plot was used. The distribution of differences was further visualized across body weights. Observing a trend related to body weight, we then performed regression analysis using body weight as a predictor of the difference between the two methods. The improvement in fit achieved by incorporating body weight was evaluated using the residual sum of squares (RSS). Results The validation method systematically underestimated the partition coefficient when the actual value by the ARG method is high, and overestimated it when the true value is low. On the Bland–Altman plot, samples with light body weight were more likely to fall into the region of lower partition coefficients, whereas samples with heavy body weight tended to fall into the region of higher partition coefficients. After correction of body weight, the distribution of partition coefficients more closely approximated an ideal pattern across all body weight groups. Regression analysis revealed that the weight-corrected model provided a significantly better fit than the assumption of a constant partition coefficient (F = 51.36, p < 0.001). The RSS was reduced by 25% following weight correction, supporting the utility of this adjustment. Conclusions The assumption of a constant arterial partition coefficient in the validation method may not be valid for individuals with light or heavy body weight. Incorporating body weight into the estimation process significantly improves even without arterial sampling. The validation method adding body weight correction may reduce variability in cerebral blood flow (CBF) estimates derived from these coefficients, which may improve the accuracy of CBF quantification even without arterial sampling.
- 19 September 2025
- Published by Springer Nature in Annals of Nuclear Medicine
- Vol. 40 (1) , 60-65
Impact of body weight on arterial partition coefficient estimation in 123I-IMP SPECT: a comparison between ARG and no-arterial sampling methods
Objective To evaluate the impact of body weight on the estimation of the arterial blood-to-whole-body partition coefficient in 123I-iodoamphetamine (IMP) SPECT using a no-arterial sampling method (validation method) and to compare it with the autoradiographic (ARG) method. Methods A total of 172 123I-IMP SPECT scans from clinical patients were retrospectively analyzed. To investigate systematic differences between the partition coefficients obtained by the ARG method and those estimated by the validation method in the QSPECT/DTARG package, a Bland–Altman plot was used. The distribution of differences was further visualized across body weights. Observing a trend related to body weight, we then performed regression analysis using body weight as a predictor of the difference between the two methods. The improvement in fit achieved by incorporating body weight was evaluated using the residual sum of squares (RSS). Results The validation method systematically underestimated the partition coefficient when the actual value by the ARG method is high, and overestimated it when the true value is low. On the Bland–Altman plot, samples with light body weight were more likely to fall into the region of lower partition coefficients, whereas samples with heavy body weight tended to fall into the region of higher partition coefficients. After correction of body weight, the distribution of partition coefficients more closely approximated an ideal pattern across all body weight groups. Regression analysis revealed that the weight-corrected model provided a significantly better fit than the assumption of a constant partition coefficient (F = 51.36, p < 0.001). The RSS was reduced by 25% following weight correction, supporting the utility of this adjustment. Conclusions The assumption of a constant arterial partition coefficient in the validation method may not be valid for individuals with light or heavy body weight. Incorporating body weight into the estimation process significantly improves even without arterial sampling. The validation method adding body weight correction may reduce variability in cerebral blood flow (CBF) estimates derived from these coefficients, which may improve the accuracy of CBF quantification even without arterial sampling.
- 8 October 2022
- Published by Springer Nature in Annals of Nuclear Medicine
- Vol. 36 (12) , 1010-1018
Effect of radioactivity outside the field of view on image quality of dedicated breast positron emission tomography: preliminary phantom and clinical studies
- 8 October 2022
- Published by Springer Nature in Annals of Nuclear Medicine
- Vol. 36 (12) , 1010-1018
Effect of radioactivity outside the field of view on image quality of dedicated breast positron emission tomography: preliminary phantom and clinical studies
- 25 November 2019
- Published by Springer Nature in Annals of Nuclear Medicine
- Vol. 34 (2) , 119-127
Comparison of dedicated breast positron emission tomography and whole-body positron emission tomography/computed tomography images: a common phantom study
High-resolution dedicated breast positron emission tomography (dbPET) can visualize breast cancer more clearly than whole-body PET/computed tomography (CT). In Japan, the combined use of dbPET and whole-body PET/CT is necessary in indications for health insurance. Although several clinical studies have compared both devices, a physical evaluation by the phantom test has not been reported. The aim of this study was to compare the ability of ring-shaped dbPET and whole-body PET/CT using a common phantom with reference to the Japanese guideline for the oncology 18F-fluorodeoxyglucose (FDG)-PET/CT data acquisition protocol.
- 25 November 2019
- Published by Springer Nature in Annals of Nuclear Medicine
- Vol. 34 (2) , 119-127
Comparison of dedicated breast positron emission tomography and whole-body positron emission tomography/computed tomography images: a common phantom study
High-resolution dedicated breast positron emission tomography (dbPET) can visualize breast cancer more clearly than whole-body PET/computed tomography (CT). In Japan, the combined use of dbPET and whole-body PET/CT is necessary in indications for health insurance. Although several clinical studies have compared both devices, a physical evaluation by the phantom test has not been reported. The aim of this study was to compare the ability of ring-shaped dbPET and whole-body PET/CT using a common phantom with reference to the Japanese guideline for the oncology 18F-fluorodeoxyglucose (FDG)-PET/CT data acquisition protocol.
- Open Access
- 1 September 2015
- Published by AIP Publishing in AIP Advances
- Vol. 5 (9) , 097182
Automatic slice-alignment method in cardiac magnetic resonance imaging for evaluation of the right ventricle in patients with pulmonary hypertension
We propose a new automatic slice-alignment method, which enables right ventricular scan planning in addition to the left ventricular scan planning developed in our previous work, to simplify right ventricular cardiac scan planning and assess its accuracy and the clinical acceptability of the acquired imaging planes in the evaluation of patients with pulmonary hypertension. Steady-state free precession (SSFP) sequences covering the whole heart in the end-diastolic phase with ECG gating were used to acquire 2D axial multislice images. To realize right ventricular scan planning, two morphological feature points are added to be detected and a total of eight morphological features of the heart were extracted from these series of images, and six left ventricular planes and four right ventricular planes were calculated simultaneously based on the extracted features. The subjects were 33 patients (25 with chronic thromboembolic pulmonary hypertension and 8 with idiopathic pulmonary arterial hypertension). The four right ventricular reference planes including right ventricular short-axis, 4-chamber, 2-chamber, and 3-chamber images were evaluated. The acceptability of the acquired imaging planes was visually evaluated using a 4-point scale, and the angular differences between the results obtained by this method and by conventional manual annotation were measured for each view. The average visual scores were 3.9±0.4 for short-axis images, 3.8±0.4 for 4-chamber images, 3.8±0.4 for 2-chamber images, and 3.5±0.6 for 3-chamber images. The average angular differences were 8.7±5.3, 8.3±4.9, 8.1±4.8, and 7.9±5.3 degrees, respectively. The processing time was less than 2.5 seconds in all subjects. The proposed method, which enables right ventricular scan planning in addition to the left ventricular scan planning developed in our previous work, can provide clinically acceptable planes in a short time and is useful because special proficiency in performing cardiac MR for patients with right ventricles of various sizes and shapes is not required.
- 1 September 2015
- Published by AIP Publishing in AIP Advances
- Vol. 5 (9) , 097182
Open AccessAutomatic slice-alignment method in cardiac magnetic resonance imaging for evaluation of the right ventricle in patients with pulmonary hypertension
We propose a new automatic slice-alignment method, which enables right ventricular scan planning in addition to the left ventricular scan planning developed in our previous work, to simplify right ventricular cardiac scan planning and assess its accuracy and the clinical acceptability of the acquired imaging planes in the evaluation of patients with pulmonary hypertension. Steady-state free precession (SSFP) sequences covering the whole heart in the end-diastolic phase with ECG gating were used to acquire 2D axial multislice images. To realize right ventricular scan planning, two morphological feature points are added to be detected and a total of eight morphological features of the heart were extracted from these series of images, and six left ventricular planes and four right ventricular planes were calculated simultaneously based on the extracted features. The subjects were 33 patients (25 with chronic thromboembolic pulmonary hypertension and 8 with idiopathic pulmonary arterial hypertension). The four right ventricular reference planes including right ventricular short-axis, 4-chamber, 2-chamber, and 3-chamber images were evaluated. The acceptability of the acquired imaging planes was visually evaluated using a 4-point scale, and the angular differences between the results obtained by this method and by conventional manual annotation were measured for each view. The average visual scores were 3.9±0.4 for short-axis images, 3.8±0.4 for 4-chamber images, 3.8±0.4 for 2-chamber images, and 3.5±0.6 for 3-chamber images. The average angular differences were 8.7±5.3, 8.3±4.9, 8.1±4.8, and 7.9±5.3 degrees, respectively. The processing time was less than 2.5 seconds in all subjects. The proposed method, which enables right ventricular scan planning in addition to the left ventricular scan planning developed in our previous work, can provide clinically acceptable planes in a short time and is useful because special proficiency in performing cardiac MR for patients with right ventricles of various sizes and shapes is not required.