MJMartin A. Janich

Martin A. Janich

*This is an algorithmically generated author record based on publicly available information.

Martin A. Janich has a total of 56 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Comparing prognostic significance of dual bolus and dual sequence quantitative stress perfusion cardiac magnetic resonance

    by Kwan Ho Leung, Haonan Wang, Eponine Kate Wong, Parco Chu, Tsun Hei Sin, Jasper Chak Fung Yip, Romelie M Tuplano, Wan Man Vivian Tse, Cheuk Nam Felix Kwan, Eric Yuk Fai Wan, et al.

    Aims: Quantitative stress perfusion (QP) cardiac magnetic resonance (CMR) can be performed using the dual sequence (DS) or dual bolus (DB) technique. DS does not require additional contrast and image acquisition but needs a research sequence. DB can be performed on all magnetic resonance imaging (MRI) scanners with standard perfusion sequences but requires additional contrast injection and image acquisition. Our aim was to compare the prognostic significance of DB and DS. Methods and Results: DB and DS were performed on the same patient and the same examination. Analysts were blinded to clinical outcomes. Stress myocardial blood flow (MBF) and myocardial perfusion reserve (MPR) were quantified. The primary outcome was a composite of major adverse cardiovascular events (MACE) comprising acute coronary syndrome, stroke, heart failure (HF) hospitalization, late revascularization, and all-cause death. 570 patients (mean age: 63.2 ± 12.3 years; 61.2% male) were recruited. Median follow-up was 743 days; 54 events were documented. All QP CMR variables demonstrated significance in univariate Cox regression [DB stress MBF [HR = 0.53 (95%CI:0.35–0.78)], DB MPR [HR = 0.38 (95%CI:0.22–0.66)], DS stress MBF [HR = 0.27 (95%CI:0.18–0.40)] and DS MPR [HR = 0.19 (95%CI:0.13–0.29)]]. On multivariable Cox regression models, only DB MPR, DS MBF, and DS MPR remained significant for MACE (HR = 0.50 (95%CI:0.28–0.89), HR = 0.35 (95%CI:0.23–0.53); HR = 0.23 (95%CI 0.15–0.36), respectively). Harrell’s C-index of DS MPR and DS stress MBF showed significantly better prognostication than their DB counterparts (P < 0.001 and P = 0.012, respectively). Conclusion: In this blinded comparison, DS stress MBF and MPR demonstrated better prognostication than DB stress MBF and MPR. Our findings support DS as the preferred approach where available.


  • Open Access

    Automatic failure mode evaluation using non-linear phase contrast correction to improve flow measurement accuracy in cardiovascular magnetic resonance phase contrast imaging

    by Ana Beatriz Solana, Savine C.S. Minderhoud, Piotr A. Wielopolski, Juan Antonio Hernandez-Tamames, Ricardo P.J. Budde, Willem A. Helbing, Martin A. Janich, Alexander Hirsch

  • Open Access

    Qualitative and Quantitative Evaluation of a Deep Learning-Based Reconstruction for Accelerated Cardiac Cine Imaging

    by Junjie Ma, Xucheng Zhu, Suryanarayanan Kaushik, Eman Ali, Liangliang Li, Kavitha Manickam, Ke Li, Martin A. Janich

    Two-dimensional (2D) cine imaging is essential in routine clinical cardiac MR (CMR) exams for assessing cardiac structure and function. Traditional cine imaging requires patients to hold their breath for extended periods and maintain consistent heartbeats for optimal image quality, which can be challenging for those with impaired breath-holding capacity or irregular heart rhythms. This study aims to systematically assess the performance of a deep learning-based reconstruction (Sonic DL Cine, GE HealthCare, Waukesha, WI, USA) for accelerated cardiac cine acquisition. Multiple retrospective experiments were designed and conducted to comprehensively evaluate the technique using data from an MR-dedicated extended cardiac torso anatomical phantom (digital phantom) and healthy volunteers on different cardiac planes. Image quality, spatiotemporal sharpness, and biventricular cardiac function were qualitatively and quantitatively compared between Sonic DL Cine-reconstructed images with various accelerations (4-fold to 12-fold) and fully sampled reference images. Both digital phantom and in vivo experiments demonstrate that Sonic DL Cine can accelerate cine acquisitions by up to 12-fold while preserving comparable SNR, contrast, and spatiotemporal sharpness to fully sampled reference images. Measurements of cardiac function metrics indicate that function measurements from Sonic DL Cine-reconstructed images align well with those from fully sampled reference images. In conclusion, this study demonstrates that Sonic DL Cine is able to reconstruct highly under-sampled (up to 12-fold acceleration) cine datasets while preserving SNR, contrast, spatiotemporal sharpness, and quantification accuracy for cardiac function measurements. It also provides a feasible approach for thoroughly evaluating the deep learning-based method.


  • Open Access

    Cardiovascular magnetic resonance left ventricular 4D-flow: differences in flow components and kinetic energy across heart failure spectrum

    by Hau Wai Wong, Haonan Wang, Chi Ting Kwan, Eponine Kate Wong, Yueyi Xu, Kwan Ho Leung, Jumatay Biekan, Jinyoung Jang, Kai-Hang Yiu, Hung-Fat Tse, et al.

    Aims: Cardiovascular magnetic resonance (CMR) 4-dimensional (4D) intraventricular flow analysis quantifies volume and kinetic energy (KE) of direct flow (DF), and residual volume (ReV) components, illustrating heart failure (HF) haemodynamic changes. Study aims were (1) compare volume and KE indexed (KEi) of DF and ReV between groups. (2) Assess relationship between 4D-flow parameters with CMR parameters. Methods and results: 187 subjects (63.0 ± 17.1 years; 101 males) comprising 78 controls, 47 HF with preserved ejection fraction (HFpEF), 25 HF with mildly reduced ejection fraction (HFmrEF), 37 HF with reduced ejection fraction (HFrEF) were included. Volume and KEi of DF, and ReV were obtained from 4D flow CMR images. Controls had highest DF volume and systolic KEi (control 35.0% and 54.7 µJ/mL), followed by HFpEF (22.7% and 61.4 µJ/mL), HFmrEF (13.1% and 43.3 µJ/mL), HFrEF (5.2% and 33.1 µJ/mL) (P < 0.001). ReV and diastolic KEi were lowest in controls (26.0% and 7.9 µJ/mL), and higher across HFpEF (31.8% and 7.8 µJ/mL), HFmrEF (41.6% and 10.8 µJ/mL), HFrEF (49.5% and 11.5 µJ/mL) (P < 0.001). DF volume correlated positively with left ventricular ejection fraction (LVEF) (r = 0.794), but negatively with LV-end-diastolic volume indexed (EDVi) (r = −0.563) (all P < 0.001). ReV correlated negatively with LVEF (r = −0.737) but positively with LV-EDVi (r = 0.602) (all P < 0.001). Loss of two diastolic peaks in KE time curves for HF patients were shown. Conclusion: CMR 4D DF and ReV with their KEi showed haemodynamic changes and KEi time curve pattern distortions in HF.


  • PERFORMANCE OF A NOVEL DEEP LEARNING-BASED MRI RECONSTRUCTION ALGORITHM TO IMPROVE MYOCARDIAL PERFUSION IMAGES

    by Hena Patel, Shuo Wang, Haonan Wang, Martin Janich, Donovan Gorre, Paul Kim, Amit Patel

  • Influence of motion correction on the visual analysis of cardiac magnetic resonance stress perfusion imaging

    by Florian von Knobelsdorff-Brenkenhoff, Stephanie Reiter, Anne Menini, Martin A. Janich, Tobias Schunke, Karl Ziegler, Roland Scheck, Berthold Höfling, Günter Pilz

    Objective Image post-processing corrects for cardiac and respiratory motion (MoCo) during cardiovascular magnetic resonance (CMR) stress perfusion. The study analyzed its influence on visual image evaluation. Materials and methods Sixty-two patients with (suspected) coronary artery disease underwent a standard CMR stress perfusion exam during free-breathing. Image post-processing was performed without (non-MoCo) and with MoCo (image intensity normalization; motion extraction with iterative non-rigid registration; motion warping with the combined displacement field). Images were evaluated regarding the perfusion pattern (perfusion deficit, dark rim artifact, uncertain signal loss, and normal perfusion), the general image quality (non-diagnostic, imperfect, good, and excellent), and the reader’s subjective confidence to assess the images (not confident, confident, very confident). Results Fifty-three (non-MoCo) and 52 (MoCo) myocardial segments were rated as ‘perfusion deficit’, 113 vs. 109 as ‘dark rim artifacts’, 9 vs. 7 as ‘uncertain signal loss’, and 817 vs. 824 as ‘normal’. Agreement between non-MoCo and MoCo was high with no diagnostic difference per-patient. The image quality of MoCo was rated more often as ‘good’ or ‘excellent’ (92 vs. 63%), and the diagnostic confidence more often as “very confident” (71 vs. 45%) compared to non-MoCo. Conclusions The comparison of perfusion images acquired during free-breathing and post-processed with and without motion correction demonstrated that both methods led to a consistent evaluation of the perfusion pattern, while the image quality and the reader’s subjective confidence to assess the images were rated more favorably for MoCo.