Laura Landa-Ruiz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Laura Landa-Ruiz has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Citlalli Gaona-Tiburcio
Autonomous University of Nuevo Leon
2 shared publications - Demetrio Nieves-Mendoza
Facultad de Ingeniería Civil, Universidad Veracruzana, Xalapa 91000, Mexico
2 shared publications - Erick Maldonado-Bandala
Facultad de Ingeniería Civil, Universidad Veracruzana, Xalapa 91000, Mexico
2 shared publications - Facundo Almeraya-Calderón
Universidad Autónoma de Nuevo León, FIME, Centro de Investigación e Innovación en Ingeniería Aeronáutica (CIIIA), San Nicolás de los Garza 66455, Mexico
2 shared publications - Francisco Estupiñan-Lopez
Universidad Autónoma de Nuevo León, FIME, Centro de Investigación e Innovación en Ingeniería Aeronáutica (CIIIA), San Nicolás de los Garza 66455, Mexico
2 shared publications - Javier Olguin-Coca
Área Académica de Ingeniería y Arquitectura, Universidad Autónoma del Estado de Hidalgo, Carretera Pachuca-Tulancingo Km. 4.5, Hidalgo 42082, Mexico
2 shared publications
Latest Publications
- Open Access
Optimization of the Hard Anodizing Process in Acidic Baths on AA6063 Aluminum Alloy Using Response Surface Methodology
The characteristics of aluminum alloys make them the most extensively used material in the aerospace sector. Aluminum, in a natural way, when interacting with oxygen, forms a protective layer of aluminum oxide, Al2O3, that enhances its properties, for example, resistance to corrosion and fatigue. This work aims to optimize the anodizing process by identifying the optimum values and combination of factors that allow the formation of an alumina layer with a thickness of 12 µm and the maximum Vickers microhardness. The parameters to be evaluated will include time, current density, and sulfuric acid concentration, which were considered variables at two levels: 15 and 20 min, 2.5 and 3.5 A/dm2, and 180 and 350 g/L, respectively. We used the response surface methodology (RSM) with a composite central design (CCD). The results of the optimization MSR reveal that to obtain the optimum Type III hard anodizing on AA6063 aluminum alloy with a target thickness of 11.85 µm and a Vickers microhardness of 297.14, a combination consisting of 15 min, 2.55 A/dm2, and 333.15 g/L of H2SO4 is required.
Open AccessOptimization of the Hard Anodizing Process in Acidic Baths on AA6063 Aluminum Alloy Using Response Surface Methodology
The characteristics of aluminum alloys make them the most extensively used material in the aerospace sector. Aluminum, in a natural way, when interacting with oxygen, forms a protective layer of aluminum oxide, Al2O3, that enhances its properties, for example, resistance to corrosion and fatigue. This work aims to optimize the anodizing process by identifying the optimum values and combination of factors that allow the formation of an alumina layer with a thickness of 12 µm and the maximum Vickers microhardness. The parameters to be evaluated will include time, current density, and sulfuric acid concentration, which were considered variables at two levels: 15 and 20 min, 2.5 and 3.5 A/dm2, and 180 and 350 g/L, respectively. We used the response surface methodology (RSM) with a composite central design (CCD). The results of the optimization MSR reveal that to obtain the optimum Type III hard anodizing on AA6063 aluminum alloy with a target thickness of 11.85 µm and a Vickers microhardness of 297.14, a combination consisting of 15 min, 2.55 A/dm2, and 333.15 g/L of H2SO4 is required.
- Open Access
Localized Corrosion of CUSTOM 450 and AM 350 Stainless Steels in H2SO4 and NaCl Solutions
Precipitation-hardenable stainless steels (PHSSs) are widely used in various applications in the aerospace industry. PHSSs are used in various parts that need to combine mechanical properties with corrosion resistance when aircrafts are in corrosive environments. This study aimed to analyze the corrosion kinetics of CUSTOM 450 and AM 350 stainless steels that were passivated in acid baths for a period of 120 min at temperatures of 25 and 50 °C and then immersed in solutions containing 1 wt. % sulfuric acid (H2SO4) and 5 wt. % sodium chloride (NaCl). The electrochemical technique used was cyclic potentiodynamic polarization (CPP) based on ASTM G61-86. Microstructural characterization was performed via optical microscopy (OM) and scanning electron microscopy (SEM). The results revealed that the potentiodynamic polarization curves have two distinct corrosion mechanisms. The immersion of PHSSs in the H2SO4 solution produces an activation–passivation reaction. The NaCl solution has pseudopassivation (unstable passivation film). The values of the icorr current densities in the solutions of sodium chloride and sulfuric acids are between 10−3 and 10−5 mA/cm2; the stainless steels are susceptible to localized pitting corrosion in both test solutions, with positive hysteresis in the CPP.
Open AccessLocalized Corrosion of CUSTOM 450 and AM 350 Stainless Steels in H2SO4 and NaCl Solutions
Precipitation-hardenable stainless steels (PHSSs) are widely used in various applications in the aerospace industry. PHSSs are used in various parts that need to combine mechanical properties with corrosion resistance when aircrafts are in corrosive environments. This study aimed to analyze the corrosion kinetics of CUSTOM 450 and AM 350 stainless steels that were passivated in acid baths for a period of 120 min at temperatures of 25 and 50 °C and then immersed in solutions containing 1 wt. % sulfuric acid (H2SO4) and 5 wt. % sodium chloride (NaCl). The electrochemical technique used was cyclic potentiodynamic polarization (CPP) based on ASTM G61-86. Microstructural characterization was performed via optical microscopy (OM) and scanning electron microscopy (SEM). The results revealed that the potentiodynamic polarization curves have two distinct corrosion mechanisms. The immersion of PHSSs in the H2SO4 solution produces an activation–passivation reaction. The NaCl solution has pseudopassivation (unstable passivation film). The values of the icorr current densities in the solutions of sodium chloride and sulfuric acids are between 10−3 and 10−5 mA/cm2; the stainless steels are susceptible to localized pitting corrosion in both test solutions, with positive hysteresis in the CPP.