Allison Bateman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Allison Bateman has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Woon-Hong Yeo
George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, USA
3 shared publications - Robert Herbert
George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA, 30332, USA; Department of Mechanical and Industrial Engineering, Louisiana State University, Baton Rouge, LA, 70803, USA
2 shared publications Bruno Rigo
Wearable Intelligent Systems and Healthcare Center (WISH Center) at the Institute for Matter and Systems, Georgia Institute of Technology, Atlanta, GA, 30332, USA; School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA, 30332, USA
1 shared publication- Bruno Rigo
Wearable Intelligent Systems and Healthcare Center (WISH Center) at the Institute for Matter and Systems Georgia Institute of Technology Atlanta GA 30332 USA
1 shared publication - Deok Hee Lee
Department of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
1 shared publication Garan Byun
George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA, 30332, USA; Wearable Intelligent Systems and Healthcare Center (WISH Center) at the Institute for Matter and Systems, Georgia Institute of Technology, Atlanta, GA, 30332, USA
1 shared publication
Latest Publications
- 4 November 2026
- Published by Elsevier in Materials Today
- Vol. 101
How material advancements are leading the charge in the next generation of implantable bioelectronics
- 4 November 2026
- Published by Elsevier in Materials Today
- Vol. 101
How material advancements are leading the charge in the next generation of implantable bioelectronics
- Open Access
- 17 October 2025
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 293, 118088
Wireless, battery-free self-detecting smart arteriovenous graft for stenosis diagnosis in dialysis patients
- 17 October 2025
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 293, 118088
Open AccessWireless, battery-free self-detecting smart arteriovenous graft for stenosis diagnosis in dialysis patients
- Open Access
- 16 February 2025
- Published by Wiley in Advanced Healthcare Materials
- Vol. 14 (13) , e2404680
Non‐Surgical, In‐Stent Membrane Bioelectronics for Long‐Term Intracranial Pressure Monitoring
Traditional intracranial pressure (ICP) monitoring methods, using intraventricular catheters, face significant limitations, including high invasiveness, discrete data, calibration complexities, and drift issues, which hinder long‐term and stable monitoring. Here, a non‐surgical, in‐stent membrane bioelectronic system is presented for continuous and reliable ICP monitoring. This platform integrates a capacitive thin‐film sensor with a stent, enabling precise real‐time detection of pressure fluctuations directly within the dural venous sinus without requiring skull penetration or frequent recalibration. The sensor demonstrates a high sensitivity of 0.052%/mmHg and a broad, readable pressure range of 3–30 mmHg while maintaining calibration‐free and drift‐free performance. A series of in vivo studies highlight the system's superior sensitivity, rapid sampling rate, and long‐term stability compared to conventional microcatheters. Statistical analyses reveal a strong agreement between the device and clinical reference, underscoring its potential to revolutionize ICP monitoring. These advancements pave the way for broader clinical applications, minimizing complications and improving patient outcomes in neurocritical care.
- 16 February 2025
- Published by Wiley in Advanced Healthcare Materials
- Vol. 14 (13) , e2404680
Open AccessNon‐Surgical, In‐Stent Membrane Bioelectronics for Long‐Term Intracranial Pressure Monitoring
Traditional intracranial pressure (ICP) monitoring methods, using intraventricular catheters, face significant limitations, including high invasiveness, discrete data, calibration complexities, and drift issues, which hinder long‐term and stable monitoring. Here, a non‐surgical, in‐stent membrane bioelectronic system is presented for continuous and reliable ICP monitoring. This platform integrates a capacitive thin‐film sensor with a stent, enabling precise real‐time detection of pressure fluctuations directly within the dural venous sinus without requiring skull penetration or frequent recalibration. The sensor demonstrates a high sensitivity of 0.052%/mmHg and a broad, readable pressure range of 3–30 mmHg while maintaining calibration‐free and drift‐free performance. A series of in vivo studies highlight the system's superior sensitivity, rapid sampling rate, and long‐term stability compared to conventional microcatheters. Statistical analyses reveal a strong agreement between the device and clinical reference, underscoring its potential to revolutionize ICP monitoring. These advancements pave the way for broader clinical applications, minimizing complications and improving patient outcomes in neurocritical care.