Zhiyuan Guo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zhiyuan Guo has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Jianfei Hua
Tsinghua University
3 shared publications Shuang Liu
Tsinghua University
3 shared publications- Yang Wan
Zhengzhou University
3 shared publications Bing Zhou
Zhengzhou University
2 shared publications- Bo Guo
Beijing Academy of Quantum Information Sciences, Beijing, China
2 shared publications Haiyang Wang
The First Affiliated Hospital of Zhengzhou University
2 shared publications
Latest Publications
- Open Access
- 25 November 2025
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 28 (11)
Dosimetric characterization of the laser-accelerated high-energy electron beam for radiotherapy applications
Radiotherapy utilizing very-high-energy electron (VHEE) beams in the range of 50–300 MeV has gained significant interest over the past two decades due to their advantageous dose characteristics, deep tissue penetration capabilities, and potential for ultrahigh dose-rate treatments. Laser wakefield accelerators (LWFAs) are particularly well suited for generating VHEE beams in a compact setup, thanks to their substantially higher accelerating gradients compared to conventional radio-frequency accelerators. To meet the demands of clinical applications, a comprehensive dosimetry study of LWFA-generated VHEE beams in a preclinical treatment configuration is essential. In this study, a VHEE beam with a maximum energy over 160 MeV was produced using a compact and stable LWFA prototype operating at 1 Hz. The beam was subsequently transported through a quadrupole triplet to eliminate low-energy components and reduce pointing jitter, followed by a scatterer and collimator to create a uniform circular radiation field with an 8-mm diameter. Using this beam, we measured the three-dimensional dose distribution within a solid-water phantom and evaluated the feasibility of multifield intensity-modulated irradiation by delivering 400 VHEE beams from 20 different angles into the phantom. This resulted in a 16-mm-diameter dose plateau peak, with the relative uniformity of approximately 2.8%, and the entrance dose was only 20% of the peak value. These findings demonstrate the feasibility and robustness of LWFA-based VHEE beams for treating deep-seated tumors, highlighting the need for dedicated engineering and preclinical studies in this promising direction.
- 25 November 2025
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 28 (11)
Open AccessDosimetric characterization of the laser-accelerated high-energy electron beam for radiotherapy applications
Radiotherapy utilizing very-high-energy electron (VHEE) beams in the range of 50–300 MeV has gained significant interest over the past two decades due to their advantageous dose characteristics, deep tissue penetration capabilities, and potential for ultrahigh dose-rate treatments. Laser wakefield accelerators (LWFAs) are particularly well suited for generating VHEE beams in a compact setup, thanks to their substantially higher accelerating gradients compared to conventional radio-frequency accelerators. To meet the demands of clinical applications, a comprehensive dosimetry study of LWFA-generated VHEE beams in a preclinical treatment configuration is essential. In this study, a VHEE beam with a maximum energy over 160 MeV was produced using a compact and stable LWFA prototype operating at 1 Hz. The beam was subsequently transported through a quadrupole triplet to eliminate low-energy components and reduce pointing jitter, followed by a scatterer and collimator to create a uniform circular radiation field with an 8-mm diameter. Using this beam, we measured the three-dimensional dose distribution within a solid-water phantom and evaluated the feasibility of multifield intensity-modulated irradiation by delivering 400 VHEE beams from 20 different angles into the phantom. This resulted in a 16-mm-diameter dose plateau peak, with the relative uniformity of approximately 2.8%, and the entrance dose was only 20% of the peak value. These findings demonstrate the feasibility and robustness of LWFA-based VHEE beams for treating deep-seated tumors, highlighting the need for dedicated engineering and preclinical studies in this promising direction.
- Open Access
- 27 October 2025
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 28 (10)
Compact dose delivery of laser-accelerated high-energy electron beams toward radiotherapy applications
The use of very high-energy electron (VHEE) beams for radiotherapy has been actively studied for over two decades due to their advantageous dose distribution, deep penetration depth, and great potential of ultrahigh dose-rate irradiation. Recently, laser-plasma wakefield accelerator (LWFA) has emerged as a promising method for the compact generation of VHEE beams, due to its substantially higher accelerating gradients compared to traditional radio-frequency accelerators. However, how to compactly deliver the LWFA-based VHEE beams of relatively large energy spread and create a maximum dose deeply inside the body remains very challenging. In this article, we present a simple dose delivery scheme utilizing only two dipole magnets for LWFA-based VHEE treatment. By adjusting the magnet strengths, the electron beams can be guided along different angular trajectories toward a precise position as deep as 20 cm within a water phantom, creating a maximum dose over the target region and significantly reducing the entrance dose. Supported by Monte Carlo simulations, such a beam delivery approach is demonstrated to be insensitive to the beam energy spread and meanwhile capable of controlling precisely the dose-peak position in both lateral and longitudinal directions. As such, a uniform dose peak can be generated by the weighted sum of VHEE beams that reach different dose-peak depths. These results demonstrate that LWFA-based VHEE beams can be compactly delivered into a deep-seated tumor region in a controllable manner, thus advancing the development of the VHEE radiotherapy toward the practical clinical applications in the near future.
- 27 October 2025
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 28 (10)
Open AccessCompact dose delivery of laser-accelerated high-energy electron beams toward radiotherapy applications
The use of very high-energy electron (VHEE) beams for radiotherapy has been actively studied for over two decades due to their advantageous dose distribution, deep penetration depth, and great potential of ultrahigh dose-rate irradiation. Recently, laser-plasma wakefield accelerator (LWFA) has emerged as a promising method for the compact generation of VHEE beams, due to its substantially higher accelerating gradients compared to traditional radio-frequency accelerators. However, how to compactly deliver the LWFA-based VHEE beams of relatively large energy spread and create a maximum dose deeply inside the body remains very challenging. In this article, we present a simple dose delivery scheme utilizing only two dipole magnets for LWFA-based VHEE treatment. By adjusting the magnet strengths, the electron beams can be guided along different angular trajectories toward a precise position as deep as 20 cm within a water phantom, creating a maximum dose over the target region and significantly reducing the entrance dose. Supported by Monte Carlo simulations, such a beam delivery approach is demonstrated to be insensitive to the beam energy spread and meanwhile capable of controlling precisely the dose-peak position in both lateral and longitudinal directions. As such, a uniform dose peak can be generated by the weighted sum of VHEE beams that reach different dose-peak depths. These results demonstrate that LWFA-based VHEE beams can be compactly delivered into a deep-seated tumor region in a controllable manner, thus advancing the development of the VHEE radiotherapy toward the practical clinical applications in the near future.
- Top Cited PapersOpen Access
- 23 February 2025
- Published by Springer Nature in Nature Communications
- Vol. 16 (1) , 1-9
Preclinical tumor control with a laser-accelerated high-energy electron radiotherapy prototype
Radiotherapy using very-high-energy electron (VHEE) beams (50-300 MeV) has attracted considerable attention due to its advantageous dose deposition characteristics, enabling deep penetration and easy manipulation by magnetic components. One promising approach to compactly delivering these high energy electron beams in a cost-effective manner is laser wakefield acceleration (LWFA), which offers ultra-strong accelerating gradients. However, the transition from this concept to a functional machine intended for tumor treatment remains elusive. Here we present the self-developed pro- totype for LWFA-based VHEE radiotherapy, exhibiting compactness (occupying less than 5 m2) and long-term operational stability (validated over a period of one month). Subsequently, we employ this device to irradiate a tumor implanted in a mouse model. Following a dose delivery of 5.8 ± 0.2 Gy with precise tumor conformity, all irradiated mice exhibit pronounced control of tumor growth. For comparison, this tumor-control efficacy is similar to that achieved using commercial X-ray radiotherapy equipment operating at equivalent doses. These results demonstrate a compact and stable laser-driven VHEE system dedicated for preclinical studies involving small animal models and its promising prospects for future clinical translation in cancer therapy.
- 23 February 2025
- Published by Springer Nature in Nature Communications
- Vol. 16 (1) , 1-9
Top Cited PapersOpen AccessPreclinical tumor control with a laser-accelerated high-energy electron radiotherapy prototype
Radiotherapy using very-high-energy electron (VHEE) beams (50-300 MeV) has attracted considerable attention due to its advantageous dose deposition characteristics, enabling deep penetration and easy manipulation by magnetic components. One promising approach to compactly delivering these high energy electron beams in a cost-effective manner is laser wakefield acceleration (LWFA), which offers ultra-strong accelerating gradients. However, the transition from this concept to a functional machine intended for tumor treatment remains elusive. Here we present the self-developed pro- totype for LWFA-based VHEE radiotherapy, exhibiting compactness (occupying less than 5 m2) and long-term operational stability (validated over a period of one month). Subsequently, we employ this device to irradiate a tumor implanted in a mouse model. Following a dose delivery of 5.8 ± 0.2 Gy with precise tumor conformity, all irradiated mice exhibit pronounced control of tumor growth. For comparison, this tumor-control efficacy is similar to that achieved using commercial X-ray radiotherapy equipment operating at equivalent doses. These results demonstrate a compact and stable laser-driven VHEE system dedicated for preclinical studies involving small animal models and its promising prospects for future clinical translation in cancer therapy.