Lixiu Zhang
Lixiu Zhang has a total of 67 co-authors. Here are the top co-authors by number of shared publications:
- Xinran Li
School of Mechanical Engineering
3 shared publications - Chengjin Zhang
School of Mechanical Engineering
2 shared publications - Fuhua Jing
School of Mechanical Engineering
2 shared publications - Huaitao Shi
Shenyang Jianzhu University
2 shared publications - Ting Li
School of Mechanical Engineering
2 shared publications - Ziyu Han
School of Mechanical Engineering
2 shared publications
Latest Publications
- 24 September 2026
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science
Sensitivity analysis and prediction of hoop stress in ceramic bearing washer based on a deep residual network surrogate model
To prevent unpredictable cracking failures induced by the thermal expansion mismatch of all-ceramic bearing washers at high temperatures, this study proposes a deep residual network (ResNet) surrogate model for predicting hoop stress. Through systematic simulations, this research reveals the underlying evolution mechanisms of hoop stress, thereby establishing fit precision design standards for ceramic bearings operating in high-temperature environments. First, a thermo-mechanical coupled finite element model of the bearing washers is developed and rigorously validated via high-temperature strain measurement experiments. Subsequently, this validated model is utilized to construct a high-fidelity dataset, which effectively trains the ResNet surrogate model. Finally, the trained model is employed to conduct global sensitivity analyses and comprehensive hoop stress predictions. The findings demonstrate that mechanical fit and temperature emerge as the dominant factors governing hoop stress, exhibiting a strong coupled amplification effect. The equivalent outer radius demonstrates a negative sensitivity; thus, increasing this dimension effectively suppresses the growth of hoop stress. Additionally, the post-assembly contact constraints between the raceway and the balls inhibit the maximum hoop stress within the bearing washers. Furthermore, machining errors introduce profound uncertainties into the hoop stress distribution. Consequently, to ensure structural reliability, the assembly clearance must be appropriately enlarged as the operating temperature increases.
- 24 September 2026
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science
Sensitivity analysis and prediction of hoop stress in ceramic bearing washer based on a deep residual network surrogate model
To prevent unpredictable cracking failures induced by the thermal expansion mismatch of all-ceramic bearing washers at high temperatures, this study proposes a deep residual network (ResNet) surrogate model for predicting hoop stress. Through systematic simulations, this research reveals the underlying evolution mechanisms of hoop stress, thereby establishing fit precision design standards for ceramic bearings operating in high-temperature environments. First, a thermo-mechanical coupled finite element model of the bearing washers is developed and rigorously validated via high-temperature strain measurement experiments. Subsequently, this validated model is utilized to construct a high-fidelity dataset, which effectively trains the ResNet surrogate model. Finally, the trained model is employed to conduct global sensitivity analyses and comprehensive hoop stress predictions. The findings demonstrate that mechanical fit and temperature emerge as the dominant factors governing hoop stress, exhibiting a strong coupled amplification effect. The equivalent outer radius demonstrates a negative sensitivity; thus, increasing this dimension effectively suppresses the growth of hoop stress. Additionally, the post-assembly contact constraints between the raceway and the balls inhibit the maximum hoop stress within the bearing washers. Furthermore, machining errors introduce profound uncertainties into the hoop stress distribution. Consequently, to ensure structural reliability, the assembly clearance must be appropriately enlarged as the operating temperature increases.
- Open Access
- 17 June 2026
- Published by Elsevier in SSRN Electronic Journal
Thermal error prediction of high-speed motorized spindles using TC-VIF-based sensor optimization and hybrid polynomial regression–LSTM modeling
Precision manufacturing heavily relies on high-speed motorized spindle equipment. Correspondingly, thermal errors generated by spindles severely curb achievable machining accuracy and stand out as a critical restrictive element. Existing thermal error models often rely on redundant sensor configurations and suffer from degraded prediction performance under varying speed conditions. This study presents a two-stage approach for motorized spindle thermal error prediction. First, we construct a thermomechanical coupled finite element model for characterizing temperature distribution and guiding the layout of measuring sensors. The Temporal Correlation–Variance Inflation Factor (TC-VIF) method is then utilized for optimization of temperature measuring positions, cutting the number of sensors from seven to four and removing multicollinearity. For thermal error modeling, a hybrid framework is developed in which second-order polynomial regression with ridge regularization captures the fundamental temperature–deformation mapping, while a two-layer LSTM models the residuals to compensate for dynamic nonlinearity. For cross-condition validation, the model is trained on three speed conditions and tested on two unseen conditions. Results show that the proposed model achieves the lowest MAE on the test set, demonstrating superior average prediction accuracy. Compared to PSO-SVM, SSA-KELM, WOA-BP, and TCN benchmarks, the hybrid model reduces MAE and RMSE by 44.8% and 40.0% on average, respectively, and achieves a coefficient of determination R² of 0.95 on the training conditions. This enhanced cross-condition generalization is attributed to the effective integration of physics-informed modeling with data-driven learning.
- 17 June 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessThermal error prediction of high-speed motorized spindles using TC-VIF-based sensor optimization and hybrid polynomial regression–LSTM modeling
Precision manufacturing heavily relies on high-speed motorized spindle equipment. Correspondingly, thermal errors generated by spindles severely curb achievable machining accuracy and stand out as a critical restrictive element. Existing thermal error models often rely on redundant sensor configurations and suffer from degraded prediction performance under varying speed conditions. This study presents a two-stage approach for motorized spindle thermal error prediction. First, we construct a thermomechanical coupled finite element model for characterizing temperature distribution and guiding the layout of measuring sensors. The Temporal Correlation–Variance Inflation Factor (TC-VIF) method is then utilized for optimization of temperature measuring positions, cutting the number of sensors from seven to four and removing multicollinearity. For thermal error modeling, a hybrid framework is developed in which second-order polynomial regression with ridge regularization captures the fundamental temperature–deformation mapping, while a two-layer LSTM models the residuals to compensate for dynamic nonlinearity. For cross-condition validation, the model is trained on three speed conditions and tested on two unseen conditions. Results show that the proposed model achieves the lowest MAE on the test set, demonstrating superior average prediction accuracy. Compared to PSO-SVM, SSA-KELM, WOA-BP, and TCN benchmarks, the hybrid model reduces MAE and RMSE by 44.8% and 40.0% on average, respectively, and achieves a coefficient of determination R² of 0.95 on the training conditions. This enhanced cross-condition generalization is attributed to the effective integration of physics-informed modeling with data-driven learning.
- 27 May 2026
- Published by American Chemical Society (ACS) in ACS Applied Nano Materials
- Vol. 9 (22) , 10061-10077
Heterostructured Ti 3 C 2 T x /Mo-CDs/NiCo-MOF Nanoadditives for Oil Lubricants
- 27 May 2026
- Published by American Chemical Society (ACS) in ACS Applied Nano Materials
- Vol. 9 (22) , 10061-10077
Heterostructured Ti 3 C 2 T x /Mo-CDs/NiCo-MOF Nanoadditives for Oil Lubricants
- 27 March 2026
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 42 (13) , 9386-9396
Quaternary Ammonium Salt-Based Deep Eutectic Solvents As Alternative Base Lubricants: Interfacial Tribological Performance
As functional solvents, deep eutectic solvents (DESs) have been widely applied in various fields. However, their application in the lubrication field remains in an exploratory stage. Existing studies are often limited by directly transplanting formulations from other domains into lubrication without a thorough investigation of formulation design. To address this gap, this study focuses on hydrogen bond acceptor quaternary ammonium salts (QASs) as a research object. By introducing long alkyl chains and dual-long-chain substituents and incorporating the hydrogen bond donor menthol (DL), three novel QAS-DL DESs were designed and synthesized. Experimental results demonstrated that with increasing alkyl chain length and number of long chain substituents, the viscosity of DESs significantly increased. In terms of tribological performance evaluation, the high-viscosity dual-long-chain DES exhibited optimal friction-reducing and antiwear properties under 60 N load due to its effective separation of friction pairs. Compared to conventional ChCl-DES, it achieved a 53.7% reduction in the average friction coefficient and a 31.1% decrease in the wear rate. The increment in the length of alkyl chains and the quantity of long-chain substituents can elevate the system viscosity, thereby enhancing the load-bearing capacity of the oil film and effectively isolating the friction interfaces. In conjunction with XPS characterization, the lubrication mechanism of QAS-DL DESs was revealed: QAS-DL DESs achieve friction reduction and wear resistance via the synergistic effect of a physically adsorbed film and the chemical reactions of iron oxide and iron chloride.
- 27 March 2026
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 42 (13) , 9386-9396
Quaternary Ammonium Salt-Based Deep Eutectic Solvents As Alternative Base Lubricants: Interfacial Tribological Performance
As functional solvents, deep eutectic solvents (DESs) have been widely applied in various fields. However, their application in the lubrication field remains in an exploratory stage. Existing studies are often limited by directly transplanting formulations from other domains into lubrication without a thorough investigation of formulation design. To address this gap, this study focuses on hydrogen bond acceptor quaternary ammonium salts (QASs) as a research object. By introducing long alkyl chains and dual-long-chain substituents and incorporating the hydrogen bond donor menthol (DL), three novel QAS-DL DESs were designed and synthesized. Experimental results demonstrated that with increasing alkyl chain length and number of long chain substituents, the viscosity of DESs significantly increased. In terms of tribological performance evaluation, the high-viscosity dual-long-chain DES exhibited optimal friction-reducing and antiwear properties under 60 N load due to its effective separation of friction pairs. Compared to conventional ChCl-DES, it achieved a 53.7% reduction in the average friction coefficient and a 31.1% decrease in the wear rate. The increment in the length of alkyl chains and the quantity of long-chain substituents can elevate the system viscosity, thereby enhancing the load-bearing capacity of the oil film and effectively isolating the friction interfaces. In conjunction with XPS characterization, the lubrication mechanism of QAS-DL DESs was revealed: QAS-DL DESs achieve friction reduction and wear resistance via the synergistic effect of a physically adsorbed film and the chemical reactions of iron oxide and iron chloride.
- 24 February 2025
- Published by American Chemical Society (ACS) in ACS Applied Nano Materials
- Vol. 8 (9) , 4470-4483
Deep Eutectic Solvent-Modified MXene as Nonpolar Lubricant Additives
- 24 February 2025
- Published by American Chemical Society (ACS) in ACS Applied Nano Materials
- Vol. 8 (9) , 4470-4483
Deep Eutectic Solvent-Modified MXene as Nonpolar Lubricant Additives
- 1 November 2022
- Published by IOP Publishing in Journal of Semiconductors
- Vol. 43 (11) , 110202
Improving reverse intersystem crossing of MR-TADF emitters for OLEDs
- 1 November 2022
- Published by IOP Publishing in Journal of Semiconductors
- Vol. 43 (11) , 110202
Improving reverse intersystem crossing of MR-TADF emitters for OLEDs
- 3 August 2022
- Published by Taylor & Francis in Expert Opinion on Drug Metabolism & Toxicology
- Vol. 18 (7-8) , 519-527
A randomized, double-blind, single-dose, parallel phase I clinical trial to compare the bioequivalence, immunogenicity, and safety of bevacizumab biosimilar and bevacizumab in healthy Chinese subjects
Bevacizumab, a humanized monoclonal antibody against VEGF, can be used as a target therapy for colorectal cancer. A phase I clinical trial was conducted to compare the bioequivalence, immunogenicity and safety of bevacizumab biosimilar (Chia Tai Tianqing Pharmaceutical Group Co., Ltd.) and Bevacizumab (Roche Diagnostics GmbH) in healthy Chinese males. Healthy Chinese subjects (N = 98) were randomly divided into two groups. A single-dose bevacizumab biosimilar or Bevacizumab was given for per cycle. Plasma drug concentrations were detected by liquid chromatography–tandem mass spectrometry (LC-MC/MS) assay. We detected the levels of anti-drug antibody (ADA) to evaluate drug immunogenicity and the safety of drugs throughout the study. The geometric mean ratios (GMRs) of AUC0-t, Cmax and AUC0-∞ for bevacizumab biosimilar and Bevacizumab were 96.27%, 93.69% and 97.01%, respectively. The 90% CIs were all within 80%-125%, meeting the bioequivalence standards. The levels of ADA were similar. In addition, the two drugs both demonstrated excellent safety in the trial. This study showed that bevacizumab biosimilar and Bevacizumab had similar pharmacokinetics (PK) parameters and safety in healthy Chinese subjects. This trial was registered in ClinicalTrials.gov (Number: NCT05476341, date registered: 25, Jul 2022) and Drug Clinical Trial Registration and Information Disclosure Platform (Number: CTR20171308, date registered: 16, Nov 2017).
- 3 August 2022
- Published by Taylor & Francis in Expert Opinion on Drug Metabolism & Toxicology
- Vol. 18 (7-8) , 519-527
A randomized, double-blind, single-dose, parallel phase I clinical trial to compare the bioequivalence, immunogenicity, and safety of bevacizumab biosimilar and bevacizumab in healthy Chinese subjects
Bevacizumab, a humanized monoclonal antibody against VEGF, can be used as a target therapy for colorectal cancer. A phase I clinical trial was conducted to compare the bioequivalence, immunogenicity and safety of bevacizumab biosimilar (Chia Tai Tianqing Pharmaceutical Group Co., Ltd.) and Bevacizumab (Roche Diagnostics GmbH) in healthy Chinese males. Healthy Chinese subjects (N = 98) were randomly divided into two groups. A single-dose bevacizumab biosimilar or Bevacizumab was given for per cycle. Plasma drug concentrations were detected by liquid chromatography–tandem mass spectrometry (LC-MC/MS) assay. We detected the levels of anti-drug antibody (ADA) to evaluate drug immunogenicity and the safety of drugs throughout the study. The geometric mean ratios (GMRs) of AUC0-t, Cmax and AUC0-∞ for bevacizumab biosimilar and Bevacizumab were 96.27%, 93.69% and 97.01%, respectively. The 90% CIs were all within 80%-125%, meeting the bioequivalence standards. The levels of ADA were similar. In addition, the two drugs both demonstrated excellent safety in the trial. This study showed that bevacizumab biosimilar and Bevacizumab had similar pharmacokinetics (PK) parameters and safety in healthy Chinese subjects. This trial was registered in ClinicalTrials.gov (Number: NCT05476341, date registered: 25, Jul 2022) and Drug Clinical Trial Registration and Information Disclosure Platform (Number: CTR20171308, date registered: 16, Nov 2017).
- 26 October 2021
- Published by Wiley in Asia-Pacific Journal of Chemical Engineering
- Vol. 17 (1) , e2722
Intrinsic kinetics of the methanol dehydration to dimethyl ether over laboratory and commercial γ‐alumina: a comparative study
The intrinsic kinetics of the methanol dehydration to dimethyl ether over the laboratory‐synthesized and commercial γ‐alumina is studied. A set of kinetic models admitting different mechanisms of the reaction is developed. The developed kinetic models, as well as the kinetic models of the methanol dehydration presented in the literature, are experimentally verified. It is shown that the kinetic model admitting Langmuir–Hinshelwood mechanism with associative methanol adsorption is the only model which describes intrinsic methanol dehydration rate over either laboratory or commercial γ‐alumina catalyst. The estimated activation energies are 121 and 128 kJ/mol, methanol adsorption heats are 45 and 70 kJ/mol, and methanol adsorption entropies are 72 and 131 J/(mol × K) for the laboratory and commercial samples, respectively. The laboratory‐synthesized γ‐alumina may be successfully used for modeling and scaling the process that utilizes the commercial γ‐alumina catalysts.
- 26 October 2021
- Published by Wiley in Asia-Pacific Journal of Chemical Engineering
- Vol. 17 (1) , e2722
Intrinsic kinetics of the methanol dehydration to dimethyl ether over laboratory and commercial γ‐alumina: a comparative study
The intrinsic kinetics of the methanol dehydration to dimethyl ether over the laboratory‐synthesized and commercial γ‐alumina is studied. A set of kinetic models admitting different mechanisms of the reaction is developed. The developed kinetic models, as well as the kinetic models of the methanol dehydration presented in the literature, are experimentally verified. It is shown that the kinetic model admitting Langmuir–Hinshelwood mechanism with associative methanol adsorption is the only model which describes intrinsic methanol dehydration rate over either laboratory or commercial γ‐alumina catalyst. The estimated activation energies are 121 and 128 kJ/mol, methanol adsorption heats are 45 and 70 kJ/mol, and methanol adsorption entropies are 72 and 131 J/(mol × K) for the laboratory and commercial samples, respectively. The laboratory‐synthesized γ‐alumina may be successfully used for modeling and scaling the process that utilizes the commercial γ‐alumina catalysts.
- 30 September 2021
- Published by JCFCorp SG PTE LTD in Tobacco Regulatory Science
- Vol. 7 (5) , 1357-1364
Clinical Analysis of Qinglongdingchuan Decoction on Acute Exacerbation of Chronic Obstructive Pulmonary Disease
Objective To explore the clinical effect of QinglongDingchuan Decoction on patients with acute exacerbation of chronic obstructive pulmonary disease (AECOPD) and analyze its mechanism. Methods From June 2017 to June 2019, patients with AECOPD were randomly divided into the observation group and the control group according to the time sequence of treatment, 40 cases in each group were observed. Control group: conventional western medicine treatment (controlled oxygen therapy, antibiotics, expectorants, bronchodilators, etc.), observation group: QinglongDingchuan decoction. 6 days is a course of observation. The routine pulmonary function, blood gas analysis, serum inflammatory factors, clinical symptoms and signs were observed. Results The observation group was superior to the control group in clinical control rate and effective rate (P < 0.05), suggesting that the treatment group was superior to the control group in overall effective rate. There were differences in symptoms, physical signs and total symptom scores between the two groups before and after treatment. The improvement of serum inflammatory factors in the treatment group was better than that in the control group. The improvement of PaC02 and Pa02 in the treatment group was better than that in the control group. Conclusion QinglongDingchuan decoction can better improve the clinical symptoms, physical signs, blood gas analysis indicators, improve the overall efficiency, and has a better effect on patients with fever AECOPD.
- 30 September 2021
- Published by JCFCorp SG PTE LTD in Tobacco Regulatory Science
- Vol. 7 (5) , 1357-1364
Clinical Analysis of Qinglongdingchuan Decoction on Acute Exacerbation of Chronic Obstructive Pulmonary Disease
Objective To explore the clinical effect of QinglongDingchuan Decoction on patients with acute exacerbation of chronic obstructive pulmonary disease (AECOPD) and analyze its mechanism. Methods From June 2017 to June 2019, patients with AECOPD were randomly divided into the observation group and the control group according to the time sequence of treatment, 40 cases in each group were observed. Control group: conventional western medicine treatment (controlled oxygen therapy, antibiotics, expectorants, bronchodilators, etc.), observation group: QinglongDingchuan decoction. 6 days is a course of observation. The routine pulmonary function, blood gas analysis, serum inflammatory factors, clinical symptoms and signs were observed. Results The observation group was superior to the control group in clinical control rate and effective rate (P < 0.05), suggesting that the treatment group was superior to the control group in overall effective rate. There were differences in symptoms, physical signs and total symptom scores between the two groups before and after treatment. The improvement of serum inflammatory factors in the treatment group was better than that in the control group. The improvement of PaC02 and Pa02 in the treatment group was better than that in the control group. Conclusion QinglongDingchuan decoction can better improve the clinical symptoms, physical signs, blood gas analysis indicators, improve the overall efficiency, and has a better effect on patients with fever AECOPD.
- 18 August 2021
- Published by Sciencedomain International
- p. 60-69
Novel Strategy to Monitor Fluid Absorption and Blood Loss during Urological Endoscopic Surgery: An Advanced Approach
Background: There is paucity of an optimal method to detect fluid absorption and hemorrhage during urological endoscopic surgery. We designed an endoscopic surgical monitoring system (ESMS) and estimated its performance to establish a practical instrument that can monitor the blood loss and fluid absorption accurately and non-invasively during urological endoscopic surgery. Methods: Our system employed the strain gauge transducers to detect the inflows and outflows of the irrigating solutions and the photoelectric sensor to determine the hemoglobin concentration of the collected irrigating fluid. The amount of blood lost and the volume of fluid absorbed during endoscopic surgery could be calculated by computer program. The accuracy and validity of this system were validated in simulated experiment and clinical study of 200 patients who underwent transurethral resection of the prostate (TURP). Results: The relative errors for fluid absorption detection were between 0.07% and 1.00% and the coefficient of variation in serial analysis ranged from 0.78% to 3.86%. Furthermore, the relative errors for blood loss detection were between 0.06% and 1.33% and the coefficient of variation in serial analysis ranged from 0.86% to 3.94%. In clinical study for TURP, the mean fluid absorption was 644 mL and blood loss was 238 mL. Conclusions: We provide the accuracy and validity of ESMS. It provides an early and real time detection and warning of irrigation fluid absorption and blood loss to make endoscopic surgical procedure safer for the patient.
- 18 August 2021
- Published by Sciencedomain International
- p. 60-69
Novel Strategy to Monitor Fluid Absorption and Blood Loss during Urological Endoscopic Surgery: An Advanced Approach
Background: There is paucity of an optimal method to detect fluid absorption and hemorrhage during urological endoscopic surgery. We designed an endoscopic surgical monitoring system (ESMS) and estimated its performance to establish a practical instrument that can monitor the blood loss and fluid absorption accurately and non-invasively during urological endoscopic surgery. Methods: Our system employed the strain gauge transducers to detect the inflows and outflows of the irrigating solutions and the photoelectric sensor to determine the hemoglobin concentration of the collected irrigating fluid. The amount of blood lost and the volume of fluid absorbed during endoscopic surgery could be calculated by computer program. The accuracy and validity of this system were validated in simulated experiment and clinical study of 200 patients who underwent transurethral resection of the prostate (TURP). Results: The relative errors for fluid absorption detection were between 0.07% and 1.00% and the coefficient of variation in serial analysis ranged from 0.78% to 3.86%. Furthermore, the relative errors for blood loss detection were between 0.06% and 1.33% and the coefficient of variation in serial analysis ranged from 0.86% to 3.94%. In clinical study for TURP, the mean fluid absorption was 644 mL and blood loss was 238 mL. Conclusions: We provide the accuracy and validity of ESMS. It provides an early and real time detection and warning of irrigation fluid absorption and blood loss to make endoscopic surgical procedure safer for the patient.