Yanlin Li
Yanlin Li has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Anrui He
Collaborative Innovation Center of Steel Technology, University of Science and Technology Beijing, Beijing, China
1 shared publication - Bo Ma
Sun Yat-sen University
1 shared publication - Chenru Zhao1 shared publication
- Deyang Gao1 shared publication
- Dun-Bao Ruan
Fuzhou University
1 shared publication - Guan-Ting Liu
Department of Engineering and System Science, National Tsing Hua University, Hsinchu, Taiwan
1 shared publication
Latest Publications
- 1 February 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (2)
Vapor bubble growth and model assessment in saturated pool boiling of water across a wide range of pressures
The growth of vapor bubbles is a complex, rapid, and elusive phenomenon involving multiple heat transfer mechanisms, such as heat conduction, microlayer evaporation, and boundary layer evaporation. To improve the understanding of the bubble growth process, this study conducted saturated pool boiling experiments under atmospheric pressure, characterizing both the bubble growth dynamics and its stochastic nature. Then, a comprehensive dataset for heterogeneous pool boiling was established by incorporating 10 additional experiments, resulting in more than 2000 data points spanning a broad range of conditions: pressures from 0.001 24 MPa to 9.57 MPa, wall superheats between 1.6 and 40 K, Jakob numbers ranging from 0.092 to 2808, and Prandtl numbers from 0.83 to 9.4. Notably, this pressure range represents the broadest range considered in the analysis of bubble growth rates, to the author's knowledge. Subsequently, a systematic evaluation of 16 existing bubble growth models and correlations—including bubble layer-based models, microlayer-based models, and empirical correlations—was performed, providing valuable insights into the dominant heat transfer mechanisms at varying pressure ranges. Finally, a new recommendation for the bubble growth rate under a wide range of conditions was provided. Specifically, Cole's correlation was recommended for Jakob numbers below 200. For Jakob numbers exceeding 200, a new correlation was proposed. The new recommendation demonstrated high accuracy in predicting both the bubble growth rate and departure diameter, with an average error of 34.3% and 32.4%, respectively.
- 1 February 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (2)
Vapor bubble growth and model assessment in saturated pool boiling of water across a wide range of pressures
The growth of vapor bubbles is a complex, rapid, and elusive phenomenon involving multiple heat transfer mechanisms, such as heat conduction, microlayer evaporation, and boundary layer evaporation. To improve the understanding of the bubble growth process, this study conducted saturated pool boiling experiments under atmospheric pressure, characterizing both the bubble growth dynamics and its stochastic nature. Then, a comprehensive dataset for heterogeneous pool boiling was established by incorporating 10 additional experiments, resulting in more than 2000 data points spanning a broad range of conditions: pressures from 0.001 24 MPa to 9.57 MPa, wall superheats between 1.6 and 40 K, Jakob numbers ranging from 0.092 to 2808, and Prandtl numbers from 0.83 to 9.4. Notably, this pressure range represents the broadest range considered in the analysis of bubble growth rates, to the author's knowledge. Subsequently, a systematic evaluation of 16 existing bubble growth models and correlations—including bubble layer-based models, microlayer-based models, and empirical correlations—was performed, providing valuable insights into the dominant heat transfer mechanisms at varying pressure ranges. Finally, a new recommendation for the bubble growth rate under a wide range of conditions was provided. Specifically, Cole's correlation was recommended for Jakob numbers below 200. For Jakob numbers exceeding 200, a new correlation was proposed. The new recommendation demonstrated high accuracy in predicting both the bubble growth rate and departure diameter, with an average error of 34.3% and 32.4%, respectively.
- Open Access
- 26 September 2022
- Published by IOS Press
- p. 105-114
Two-Layer Control Strategy of the PCM-Based Electric Heating Optimal Control System Using LSTM Algorithm
- 26 September 2022
- Published by IOS Press
- p. 105-114
Open AccessTwo-Layer Control Strategy of the PCM-Based Electric Heating Optimal Control System Using LSTM Algorithm
- 1 March 2020
- Published by American Scientific Publishers in Science of Advanced Materials
- Vol. 12 (3) , 441-448
Enhanced Adsorption of Chromium by Stabilized Ca/Al–Fe Layered Double Hydroxide Decorated with Ferric Nanoparticles
Two-dimension magnetic double layer hydroxide nanoparticles (Ca–Al/Fe LDH) were synthesized by the hydrothermal method. Here, we demonstrate a potential method for efficient chromium removal using Ca–Al/Fe LDH as the adsorbent in water treatment. It was found that Cr(VI) could be successfully eliminated using the Ca–Al/Fe LDH. The method achieved extremely fast removal of Cr(VI) from water with high adsorption capacities. As-prepared Ca–Al/Fe LDH had a high specific surface area and anti-agglomeration property, which contributed to preventing nanometer metal particles from conglomerating during the adsorption process. The recycling studies indicated that Ca–Al/Fe LDH exhibited intense chromium absorption in simulated high levels of pollution wastewater. This modified synthetic approach could extend the application of Ca–Al/Fe LDH for heavy metal control by enhancing their adsorption and desorption capacity in wastewater treatment. Furthermore, the modified synthetic method could be used to produce a suite of stabilized, non-toxic chemical magnetic nanoparticles, and could be used for industrial production.
- 1 March 2020
- Published by American Scientific Publishers in Science of Advanced Materials
- Vol. 12 (3) , 441-448
Enhanced Adsorption of Chromium by Stabilized Ca/Al–Fe Layered Double Hydroxide Decorated with Ferric Nanoparticles
Two-dimension magnetic double layer hydroxide nanoparticles (Ca–Al/Fe LDH) were synthesized by the hydrothermal method. Here, we demonstrate a potential method for efficient chromium removal using Ca–Al/Fe LDH as the adsorbent in water treatment. It was found that Cr(VI) could be successfully eliminated using the Ca–Al/Fe LDH. The method achieved extremely fast removal of Cr(VI) from water with high adsorption capacities. As-prepared Ca–Al/Fe LDH had a high specific surface area and anti-agglomeration property, which contributed to preventing nanometer metal particles from conglomerating during the adsorption process. The recycling studies indicated that Ca–Al/Fe LDH exhibited intense chromium absorption in simulated high levels of pollution wastewater. This modified synthetic approach could extend the application of Ca–Al/Fe LDH for heavy metal control by enhancing their adsorption and desorption capacity in wastewater treatment. Furthermore, the modified synthetic method could be used to produce a suite of stabilized, non-toxic chemical magnetic nanoparticles, and could be used for industrial production.
- 1 August 2019
- Published by Elsevier in Microelectronic Engineering
- Vol. 216, 111034
Radiation effects and reliability characteristics of Ge pMOSFETs
- 1 August 2019
- Published by Elsevier in Microelectronic Engineering
- Vol. 216, 111034
Radiation effects and reliability characteristics of Ge pMOSFETs
- Open Access
- 3 April 2019
- Published by SAGE Publications in Advances in Mechanical Engineering
- Vol. 11 (4)
Effect of strip edge temperature drop of electrical steel on profile and flatness during hot rolling process
The purpose of this article is to solve the uneven deformation problem of electrical steel strip caused by high-temperature phase transition during hot rolling process. The hot rolling process of electrical steel strip is built by ABAQUS software, importing the constitutive model of electrical steel. The effect of temperature drop in the edge of electrical steel strip on the profile and flatness of strip is studied. Simulation results show that the strip edge temperature drop has great effect on hot rolling process of electrical steel strip. When electrical steel strip is in single-phase state, the strip edge temperature drop can reduce the strip crown, but also lead to larger rolling pressure and local high point height in the strip edge. When electrical steel strip is in two-phase state, the local high point height in the strip edge does not exist, but the strip edge temperature drop can lead to larger strip crown.
- 3 April 2019
- Published by SAGE Publications in Advances in Mechanical Engineering
- Vol. 11 (4)
Open AccessEffect of strip edge temperature drop of electrical steel on profile and flatness during hot rolling process
The purpose of this article is to solve the uneven deformation problem of electrical steel strip caused by high-temperature phase transition during hot rolling process. The hot rolling process of electrical steel strip is built by ABAQUS software, importing the constitutive model of electrical steel. The effect of temperature drop in the edge of electrical steel strip on the profile and flatness of strip is studied. Simulation results show that the strip edge temperature drop has great effect on hot rolling process of electrical steel strip. When electrical steel strip is in single-phase state, the strip edge temperature drop can reduce the strip crown, but also lead to larger rolling pressure and local high point height in the strip edge. When electrical steel strip is in two-phase state, the local high point height in the strip edge does not exist, but the strip edge temperature drop can lead to larger strip crown.