MKMohammad Khalid

Mohammad Khalid

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Mohammad Khalid has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    “Resuscitation on the go”- Musculoskeletal discomfort, CPR quality and provider experiences in a transit ambulance setting: A simulated, mixed-methods study

    by Caroline Ashritha Maben, Prithvishree Ravindra, Abraham Samuel Babu, Mohammad Khalid, B. N. Lavanya, Ankit Kumar Sahu, Vimal Krishnan S

    Background: Performing high-quality cardiopulmonary resuscitation (CPR) in a moving ambulance poses biomechanical and ergonomic challenges. This pilot study aimed to evaluate musculoskeletal discomfort, CPR quality, and provider posture, while exploring the experiences of healthcare providers delivering CPR in a moving ambulance. Methods: A mixed-methods study involving 30 Emergency Medical Service (EMS) providers and students aged 18–40 years trained in Basic Life Support was conducted. Participants performed CPR simulation in an in-hospital stationary setting and a moving ambulance using a Little Anne ® QCPR mannequin (Laerdal Medical, Stavanger, Norway). Musculoskeletal discomfort was assessed before and after CPR in the moving ambulance using the Numerical Pain Rating Scale. CPR quality parameters, including compression score, depth, rate, recoil, and chest compression fraction, were recorded using the QCPR ® app. Body posture was assessed using mean trunk and elbow angles during compression and recoil. Semi-structured interviews explored participants’ experiences. Results: Median pain scores increased significantly after CPR in the moving ambulance [0 (0, 2.75) before vs. 4 (0, 6) after; p < 0.001]. The most common pain sites were the lumbar region and wrists. Chest compression score and good rate percentage were lower in the moving setting. Trunk and elbow angles showed greater flexion in the moving ambulance, with changes observed across consecutive CPR cycles. Qualitative analysis revealed themes of physical fatigue, balance issues, safety concerns, and ergonomic limitations. Participants recommended simulation-based training, improved ambulance design, and mechanical CPR devices. Conclusion: CPR in a moving ambulance was associated with increased musculoskeletal discomfort and lower CPR quality metrics. Ergonomic modifications, provider training, and mechanical aids may help address these challenges. Further studies with larger and more diverse populations and real-world transport conditions are warranted. Trial registration: Prospectively registered in Clinical Trial Registry India (CTRI/2024/09/073482) on September 5th, 2024.

  • Open Access

    Unlocking Cardiac Insights: Displacement of Aortic Root for Calculation of Ejection Fraction in Emergency Department in India

    by Sudhi Manu, Gopinathan Vivek, Asanaru Kunju Sanjan, A. Ajay, S. Nisarg, Mymbilly Balakrishnan Jayaraj, T.R. Aishwarya, Mohammad Khalid, S. Chetana

    Introduction: Assessing cardiac function is crucial for managing acute dyspnea. In this study we aimed to evaluate displacement of the aortic root (DAR) as a method for calculating ejection fraction (EF) in patients with undifferentiated dyspnea presenting to the emergency department (ED). The primary objective was to compare EF values obtained through DAR with the modified Simpson method, which is considered the criterion reference, within an Indian academic ED. Methods: We conducted a prospective, cross-sectional study spanning two years (December 2019–December 2021). The study enrolled 110 consecutive ED patients ≥18 years of age, presenting with undifferentiated dyspnea and normal sinus rhythm. Ultrasound-trained investigators measured DAR using M-mode ultrasonography. Experienced echocardiographers, blinded to DAR, determined EF using the modified Simpson method. Statistical analyses included the Shapiro-Wilk test, McNemar test, and the receiver operating characteristic curve. Results: The mean DAR measurement was 0.781 centimeters, with an average calculated EF of 54.4%. The EF calculated using DAR did not differ significantly from EF calculated using the modified Simpson method. Comparative analysis revealed DAR’s superior sensitivity (86.21%) compared to mitral annular plane systolic excursion (48.28%) and end-point septal separation (45.45%). The DAR method exhibited high accuracy (area under the curve = 0.958) with a cut-off value 0.706 (sensitivity 88.7%, specificity 93.1%). Conclusion: Evaluating displacement of the aortic root to calculate ejection fraction in undifferentiated dyspnea demonstrated high accuracy, sensitivity, and agreement with the modified Simpson method, which is considered the criterion reference. Its simplicity and non-invasiveness makes it a valuable initial screening tool in emergency settings, with the potential to reshape cardiac assessment approaches and optimize patient care pathways in the ED.