TAT. A. Anosova

T. A. Anosova

*This is an algorithmically generated author record based on publicly available information.

T. A. Anosova has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Possibilities of Using Magnetic Resonance Imaging with Proton Density Lipid Fraction Assessment for Diagnosing Steatosis Post-Liver Transplantation

    by T. A. Anosova, E. A. Ionova, V. V. Kapustin, E. I. Matkevich, E. A. Dubova

    Objective . To evaluate the effectiveness of steatosis detection in liver transplant patients using magnetic resonance imaging with proton density quantification of liver fat fraction (PDFF). Materials and methods. А total of 113 liver transplant recipients (61 women and 52 men) aged 19 to 72 years were examined. All patients underwent magnetic resonance imaging (MRI) with proton density quantification of liver fat fraction. The obtained MRI (PDFF) data were compared with biopsy results. Calculation of the percentage of fatty infiltration of the liver based on right lobe liver biopsy data was used as a reference method. Results. According to biopsy data, steatosis was absent in 81 patients (72 %), while steatosis of varying severity was detected in 32 patients (28 %). The comparison revealed significant differences in the PDFF (p ≤ 0.001) between patients with and without steatosis. The optimal cutoff value for distinguishing between normal and the presence of steatosis was 5.2 % (sensitivity 93 %, specificity 65 %). The correlation coefficient between PDFF methods and biopsy data was 0.66 (p ≤ 0.01). Conclusions. Thus, magnetic resonance imaging with proton density lipid fraction (PDFF) assessment is a highly informative method for diagnosing fatty liver disease, including in patients after liver transplantation. Determining cutoff values for the severity of fatty liver disease requires further research.

  • ОГРАНИЧЕНИЯ ЛОКАЛЬНЫХ ИЗМЕРЕНИЙ ПРОТОННОЙ ПЛОТНОСТИ ЖИРОВОЙ ФРАКЦИИ ПЕЧЕНИ: РОЛЬ ПРОСТРАНСТВЕННОЙ НЕОДНОРОДНОСТИ СТЕАТОЗА

    by Ю.н. Савченков, Г.е. Труфанов, В.а. Фокин, Е.а. Ионова, Т.а. Аносова, О.в. Бодрова, М.м. Рогаль

    Цель: оценить методологические ограничения локальных измерений протонной плотности жировой фракции печени и проанализировать влияние площади и количества зон интереса на воспроизводимость среднепеченочного значения данного показателя. Материал и методы: проведен ретроспективный анализ данных мультипараметрической магнитно-резонансной томографии печени с количественной оценкой стеатоза на основе протонной плотности жировой фракции. Выполнено сопоставление локальных и усредненных значений показателя при использовании различных стратегий выбора зон интереса с оценкой воспроизводимости по отклонению от среднепеченочного значения. Результаты:показано, что локальные измерения протонной плотности жировой фракции характеризуются выраженной вариабельностью относительно среднепеченочного значения, обусловленной пространственной внутриорганной неоднородностью стеатоза печени. Увеличение количества зон интереса приводит к закономерному снижению ошибки локального измерения за счет эффекта усреднения. В то же время увеличение площади одиночной зоны интереса снижает вариабельность лишь частично и не является эквивалентной альтернативой многоочаговому подходу. Заключение:пространственная внутриорганная неоднородность стеатоза печени является ключевым фактором, определяющим ограниченную воспроизводимость локальных измерений протонной плотности жировой фракции. Для корректной количественной оценки стеатоза печени при магнитно-резонансной томографии целесообразно использование многоочаговой стратегии выбора зон интереса, обеспечивающей более надежное воспроизведение среднепеченочного значения показателя. Aim: was to assess the methodological limitations of local measurements of liver proton density fat fraction and to analyze the impact of region-of-interest size and number on the reproducibility of the mean hepatic value of this parameter. Material and methods: a retrospective analysis of multiparametric liver magnetic resonance imaging data with quantitative assessment of hepatic steatosis based on proton density fat fraction was performed. Local and averaged values were compared using different region-of-interest selection strategies, with reproducibility assessed by deviation from the mean hepatic value. Results: it was shown that local measurements of proton density fat fraction demonstrate pronounced variability relative to the mean hepatic value, which is attributable to spatial intrahepatic heterogeneity of hepatic steatosis. An increase in the number of regions of interest resulted in a consistent reduction of local measurement error due to the averaging effect. In contrast, enlargement of a single region of interest reduced variability only partially and was not equivalent to a multi-site measurement approach. Conclusion: spatial intrahepatic heterogeneity of hepatic steatosis is a key factor limiting the reproducibility of local proton density fat fraction measurements. For accurate quantitative assessment of hepatic steatosis using magnetic resonance imaging, a multi-site region-of-interest strategy should be applied to ensure more reliable reproduction of the mean hepatic value.

  • ОГРАНИЧЕНИЯ ЛОКАЛЬНЫХ ИЗМЕРЕНИЙ ПРОТОННОЙ ПЛОТНОСТИ ЖИРОВОЙ ФРАКЦИИ ПЕЧЕНИ: РОЛЬ ПРОСТРАНСТВЕННОЙ НЕОДНОРОДНОСТИ СТЕАТОЗА

    by Ю.н. Савченков, Г.е. Труфанов, В.а. Фокин, Е.а. Ионова, Т.а. Аносова, О.в. Бодрова, М.м. Рогаль

    Цель: оценить методологические ограничения локальных измерений протонной плотности жировой фракции печени и проанализировать влияние площади и количества зон интереса на воспроизводимость среднепеченочного значения данного показателя. Материал и методы: проведен ретроспективный анализ данных мультипараметрической магнитно-резонансной томографии печени с количественной оценкой стеатоза на основе протонной плотности жировой фракции. Выполнено сопоставление локальных и усредненных значений показателя при использовании различных стратегий выбора зон интереса с оценкой воспроизводимости по отклонению от среднепеченочного значения. Результаты:показано, что локальные измерения протонной плотности жировой фракции характеризуются выраженной вариабельностью относительно среднепеченочного значения, обусловленной пространственной внутриорганной неоднородностью стеатоза печени. Увеличение количества зон интереса приводит к закономерному снижению ошибки локального измерения за счет эффекта усреднения. В то же время увеличение площади одиночной зоны интереса снижает вариабельность лишь частично и не является эквивалентной альтернативой многоочаговому подходу. Заключение:пространственная внутриорганная неоднородность стеатоза печени является ключевым фактором, определяющим ограниченную воспроизводимость локальных измерений протонной плотности жировой фракции. Для корректной количественной оценки стеатоза печени при магнитно-резонансной томографии целесообразно использование многоочаговой стратегии выбора зон интереса, обеспечивающей более надежное воспроизведение среднепеченочного значения показателя. Aim: was to assess the methodological limitations of local measurements of liver proton density fat fraction and to analyze the impact of region-of-interest size and number on the reproducibility of the mean hepatic value of this parameter. Material and methods: a retrospective analysis of multiparametric liver magnetic resonance imaging data with quantitative assessment of hepatic steatosis based on proton density fat fraction was performed. Local and averaged values were compared using different region-of-interest selection strategies, with reproducibility assessed by deviation from the mean hepatic value. Results: it was shown that local measurements of proton density fat fraction demonstrate pronounced variability relative to the mean hepatic value, which is attributable to spatial intrahepatic heterogeneity of hepatic steatosis. An increase in the number of regions of interest resulted in a consistent reduction of local measurement error due to the averaging effect. In contrast, enlargement of a single region of interest reduced variability only partially and was not equivalent to a multi-site measurement approach. Conclusion: spatial intrahepatic heterogeneity of hepatic steatosis is a key factor limiting the reproducibility of local proton density fat fraction measurements. For accurate quantitative assessment of hepatic steatosis using magnetic resonance imaging, a multi-site region-of-interest strategy should be applied to ensure more reliable reproduction of the mean hepatic value.

  • Open Access

    Capabilities of magnetic resonance imaging in quantitative assessment hepatic steatosis in patients with different body mass index

    by Yu. N. Savchenkov, G. E. Trufanov, V. A. Fokin, E. A. Ionova, T. A. Anosova, A. V. Anisonyan, E. S. Sbikina, O. V. Bodrova

    Purpose. To evaluate the association between the severity of hepatic steatosis, quantitatively determined by the mean whole-liver proton density fat fraction on magnetic resonance imaging (MRI), and body mass index (BMI) in the examined patients. Materials and methods. A retrospective observational study included 776 patients who underwent multiparametric abdominal magnetic resonance imaging on Magnetom Vida (Siemens) 3 T and Ingenia Ambition S (Philips) 1.5 T scanners. BMI was calculated using the standard formula and considered a systemic anthropometric indicator of obesity. Quantitative assessment of hepatic steatosis was performed using the mean whole-liver proton density fat fraction. Steatosis severity was classified as S 0-S 3. Nonparametric statistical methods were used, including Spearman correlation analysis, intergroup comparisons with Benjamini-Hochberg correction for multiple testing, and ROC analysis. Results. A statistically significant positive correlation was found between hepatic proton density fat fraction and BMI (p=0.569; pS 1, 0.761 for >S 2, and 0.706 for >S 3, corresponding to moderate to low discriminative performance. Conclusion. BMI is statistically associated with the severity of hepatic steatosis but demonstrates high variability and pronounced overlap between steatosis grades. The presence of hepatic steatosis in 9 % of patients with normal BMI and its absence in 36 % of patients with obesity reflect the limited diagnostic value of BMI for assessing the degree of hepatic fat infiltration. Quantitative assessment of proton density fat fraction by MRI provides an objective and reproducible characterization of hepatic steatosis regardless of BMI category.

  • Open Access

    Shear-Wave Dispersion Slope (SWDS) is a new ultrasound parameter to detect liver inflammation

    by B. I. Zykin, E. A. Ionova, T. A. Anosova

    Background: one of the most pressing problems of ultrasound shear wave elastometry of the liver is the lack of distinct digital differential diagnostic criteria for the presence and severity of fibrosis in inflammation. Purpose. To evaluate the possibility of a new ultrasonic parameter – the shear wave dispersion slope (SWDS) in solving this problem. Materials and methods . 156 patients with various liver pathologies were examined. Depending on the absence or presence of fibrosis, as well as inflammatory changes in the liver (according to biopsy and serological blood tests), the examined patients were divided into three groups. The control group consisted of 10 healthy donors. Measurements of the shear wave velocity (SWS), shear wave dispersion slope (SWDS) and the assessment of ultrasound attenuation (ATI) in the liver were performed using the Canon Medical Aplio i800 ultrasound diagnostic system (Tokyo, Japan) using a standard convex transducer. Results . The indicators of SWS, SWDS and ATI (Median and 95% CI) in the control group were Me 1.2 (95% CI 1.1–1.6) m/s, Me 10.1 (95% CI 9.7–14.3) m/s/kHz and Me 0.54 (95% CI 0.41–0.63) dB/cm/MHz, respectively. The study of the main group showed that there is a close correlation between SWS and SWDS (Spearman's rho = 0.74). At the same time, patients in the subgroup with inflammation had significantly (p < 0.01) higher SWDS values compared with the control group and the subgroup without inflammation – Me 16.4 (95% CI 15.3–17.9) m/s/kHz versus Me 10.1 (95% CI 9.7–14.3) m/s/kHz and Me 12.7 (95%CI 12.1–14.3) m/s/kHz. In patients of the subgroup with fibrosis, but without inflammation, there was also a significant (p < 0.01) increase in SWDS from Me 12,0 (95% CI 11.4–12.8) m/s/kHz at F0-1 to Me 16,5 (95% CI 12.9–20.3) m/s/kHz at F3–4 METAVIR. Conclusion. The use of absolute SWDS values did not contribute to the achievement of the purpose of this study – the detection of criteria for the differential diagnosis of the presence and severity of liver fibrosis in patients with hepatitis. Nevertheless, the results of the study provide grounds for making a fairly confident conclusion that the assessment of the relationship between SWDS and SWS using the binary logistic regression formula ( logit(p) = 0, 4152 SWDS ( м / с / кГц ) – 0,1344 SWS ( м / с ) – 6,5115) can become a valuable additional method for ultrasound diagnostics of inflammatory changes in the liver.