TKTalat Kırış

Talat Kırış

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Talat Kırış has a total of 7 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Comparative Analysis of Frameless Robotic Stereotactic Biopsy with Intraoperative Sodium Fluorescein Versus Frame-Based Stereotactic Technique

    by Utku Özgen, Mehmet Zeki Yıldız, Mehmet Osman Akçakaya, Talat Kırış

    Background and Objectives: The authors aimed to describe their experience performing frameless stereotactic biopsies using an Autoguide Robotic Platform and to compare the outcomes with a frame-based stereotactic technique. We would like to emphasize the importance of this study, as it is the first in the literature to use sodium fluorescein for confirmation in intracranial biopsies taken with a Stealth Autoguide Robotic Platform. Materials and Methods: We retrospectively evaluated 30 patients who underwent a stereotactic intracranial biopsy between June 2018 and March 2024. The patients were divided into two groups: The robotic biopsy group (n = 15) underwent a frameless image-guided stereotactic intracranial biopsy with a Stealth Autoguide Robotic Platform and optical neuronavigation system (Stealth-Station S8, Medtronic, Minneapolis, MN, USA) using intraoperative sodium fluorescein. The frame-based (Integra, CRW, New Jersey, USA) stereotactic biopsy group (n = 15) underwent a stereotactic biopsy with the use of a stereotactic planning system (Atlas Integra Software, NJ, USA and Brainlab AG, Munich, Germany) without sodium fluorescein. Preoperative MRI and CT scans were performed in all the patients. Their external cranial anatomy was registered using either facial tracing or O-Arm (Medtronic Sofamor Danek, Inc., Memphis, TN, USA). Results: The robotic biopsy group demonstrated a diagnostic yield of 93.3% (14/15), while the frame-based group achieved 100% (15/15), with no significant difference (p = 0.609). The mean calculated tip error in the robotic biopsy group was 0.42 ± 0.19 mm (range: 0.1–0.7 mm) and the postoperative targeting accuracy in the frame-based biopsy group was 0.51 ± 0.23 mm (range: 0.2–0.9 mm), with no significant difference (p = 0.287). The robotic biopsy group demonstrated a significantly shorter mean surgical time (40.26 ± 6.13 vs. 52.47 ± 8.92 min, p = 0.002). Conclusions: Both frame-based and robotic-assisted stereotactic biopsy techniques achieve comparable diagnostic accuracy and targeting precision. However, a robotic biopsy significantly reduces the surgical time compared to a frame-based technique. The use of intraoperative sodium fluorescein is a valuable adjunct method for confirming that biopsy specimens are obtained from the intended target site.


  • Open Access

    Comparative Analysis of Frameless Robotic Stereotactic Biopsy with Intraoperative Sodium Fluorescein Versus Frame-Based Stereotactic Technique

    by Utku Özgen, Mehmet Zeki Yıldız, Mehmet Osman Akçakaya, Talat Kırış

    Background and Objectives: The authors aimed to describe their experience in frameless stereotactic biopsy by using Autoguide Robotic Platform and compare outcomes with frame-based stereotactic technique. We would like to emphasize the importance of this study as it is the first in the literature to use sodium fluorescein for confirmation in intracranial biopsies taken with the Stealth Autoguide Robotic Platform. Materials and Methods: We retrospectively evaluated 30 patients who underwent stereotactic intracranial biopsy between June 2018 and March 2024. Patients were divided into two groups: Robotic biopsy group (n=15) underwent frameless image-guided stereotactic intracranial biopsy with Stealth Autoguide Robotic Platform and optical neuronavigation system (Stealth-Station S8, Medtronic, Minneapolis, MN, USA) by using intraoperative sodium fluorescein. Frame-based (Integra, CRW, New Jersey, USA) stereotactic biopsy group (n=15) underwent stereotactic biopsy with the use of a stereotactic planning system (Atlas Integra Software, New Jersey, USA and Brainlab AG, Munich, Germany), without sodium fluorescein and preoperative MRI and CT scans were performed in all patients. The external cranial anatomy was registered using either facial tracing or O-Arm (Medtronic Sofamor Danek, Inc., Memphis, TN, USA). Results: Robotic biopsy group demonstrated diagnostic yield of 93.3% (14/15) while frame-based group achieved 100% (15/15), with no significant difference (p=0.609). Mean calculated tip error in robotic biopsy group was 0.42±0.19 mm (range: 0.1-0.7 mm) and postoperative targeting accuracy in frame-based biopsy group was 0.51±0.23 mm (range: 0.2-0.9 mm), with no significant difference (p=0.287). robotic biopsy group demonstrated significantly shorter mean surgical time (40.26±6.13 vs 52.47±8.92 minutes, p=0.002). Conclusions: Both frame-based and robotic-assisted stereotactic biopsy techniques achieve comparable diagnostic accuracy and targeting precision. However, robotic biopsy significantly reduces surgical time compared to frame-based technique. The use of intraoperative sodium fluorescein is a valuable adjunct method for confirming that biopsy specimens are obtained from the intended target site.

  • Safety and efficacy of ultrasonic bone scalpel compared with a high-speed drill in spinal surgery: our experience in sixty cases

    by Utku Özgen, Ahmet Tulgar Başak, Mehdi Hekimoğlu, Mehmet Osman Akçakaya, Tunç Öktenoğlu, Ali Fahir Özer, Talat Kırış

    Purpose In this study, we aimed to evaluate the effectiveness and safety of UBS (Ultrasonic Bone Scalpel) and HSD (High-speed drill) for performing anterior or posterior decompressions in patients with pathologies in cervical and lumbar regions. Methods Between October 2022 and June 2024, 60 patients underwent surgery in which a UBS (Sonopet UST-2001; Stryker Neuro Spine ENT, MI, USA) and High-speed Midas Rex MR8 (Medtronic, Fort Worth, TX, USA) drill was used. Informed consent was obtained from all patients. The study included 27 men and 33 women with a mean age of 59,5 ± 14.6 years (range: 28–85). The following patient data were recorded: preoperative and postoperative JOA scores, intraoperative blood loss, and operative time for decompression in lumbar and cervical region. Results In UBS group, the mean intraoperative blood loss was 166.0 ± 64.3 ml. The mean preoperative and postoperative JOA scores were 4.5 ± 1.0 and 8.6 ± 1.8 and the mean postoperative follow-up duration was 6.1 ± 4.4 months in UBS group. The mean intraoperative blood loss was 221.2 ± 93.4 ml in HSD group. The mean preoperative and postoperative JOA scores were 5.2 ± 1.1 and 8.2 ± 1.2 in HSD group. In the HSD group, the blood loss (BL) value was significantly higher (p < 0.05) compared to the UBS group. The preoperative/postoperative JOA score improvement in the UBS group was significantly higher (p < 0.05) than in the HSD group. Conclusions The UBS can be safely used in spinal surgery. It reduces intraoperative blood loss and provide better clinical improvement. Authors would like to emphasize that the UBS resects the bone with oscillatory movements rather than rolling motions and this mechanism of action is important in reducing the risk of dura mater injury.