Banothu Somanna
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Banothu Somanna has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
Sushma Gupta
4 shared publications- Sushma Gupta
Maulana Azad National Institute of Technology
3 shared publications Abdulrahman Babqi
Department of Electrical Engineering, College of Engineering, Taif University, Taif, Saudi Arabia
1 shared publication- Abdulrahman Babqi
Department of Electrical Engineering, College of Engineering, Taif University, Taif 21944, Saudi Arabia
1 shared publication - Borchala Namomsa
Department of Electrical and Computer Engineering, Jimma University Institute of the Technology Jit, Jimma Town, Ethiopia
1 shared publication - Borchala Namomsa
Jimma University Institute of the Technology Jit, Jimma Town
1 shared publication
Latest Publications
- 26 April 2026
- Published by Elsevier in Renewable Energy Focus
- Vol. 58
Adaptive Control-Based Fault Detection Framework for Stable DC Microgrid Operation
- 26 April 2026
- Published by Elsevier in Renewable Energy Focus
- Vol. 58
Adaptive Control-Based Fault Detection Framework for Stable DC Microgrid Operation
- 29 March 2026
- Published by Elsevier in Renewable Energy Focus
- Vol. 58
Intelligent optimization and adaptive fault management framework for resilient and high-performance DC microgrids
- 29 March 2026
- Published by Elsevier in Renewable Energy Focus
- Vol. 58
Intelligent optimization and adaptive fault management framework for resilient and high-performance DC microgrids
- Open Access
- 24 March 2026
- Published by EDP Sciences in Science and Technology for Energy Transition
- Vol. 81, 3
Advanced algorithm for fault detection and localization in DC microgrids utilizing capacitor current transient analysis for enhanced reliability in DER-integrated systems
This paper presents an advanced Short-Circuit (SC) fault detection and location methodology for DC Microgrids (DCMGs) integrating Distributed Energy Resources (DERs). Unisolated SC faults in DC systems present a significant challenge, leading to service disruptions and hindering effective fault detection. To address this, the proposed method capitalizes on the capacitor-dominated characteristics of DCMGs by utilizing capacitor current dynamics. A comprehensive DCMG system model is developed to facilitate the application and evaluation of the proposed scheme. The algorithm employs the average capacitor current and cable resistance to accurately determine the occurrence and location of faults within the DCMG network. Active DER sources (solar PV, wind, utility grid, and batteries) connect to loads via DC–DC converters, cables, relays, and circuit breakers. The method effectively detects the average capacitor current, enabling the identification of internal faults. Faults are classified as external if a set criterion is not met. Furthermore, the paper proposes a redundancy-based isolation configuration for zonal-type distributed networks. The efficacy of the methodology is rigorously validated through digital simulation studies. MATLAB/Simulink simulations of a DCMG, incorporating diverse generation sources and loads, are conducted under various fault scenarios. These include internal and external faults, as well as Line-to-Ground (LG) and Line-to-Line (LL) faults. The simulation results demonstrate the method’s ability to accurately detect both Low-Impedance Faults (LIFs) and High-Impedance Faults (HIFs) and to locate the faulty cable. Notably, the approach achieves fault cable detection and isolation within 2.3 ms, confirming its effectiveness and speed.
- 24 March 2026
- Published by EDP Sciences in Science and Technology for Energy Transition
- Vol. 81, 3
Open AccessAdvanced algorithm for fault detection and localization in DC microgrids utilizing capacitor current transient analysis for enhanced reliability in DER-integrated systems
This paper presents an advanced Short-Circuit (SC) fault detection and location methodology for DC Microgrids (DCMGs) integrating Distributed Energy Resources (DERs). Unisolated SC faults in DC systems present a significant challenge, leading to service disruptions and hindering effective fault detection. To address this, the proposed method capitalizes on the capacitor-dominated characteristics of DCMGs by utilizing capacitor current dynamics. A comprehensive DCMG system model is developed to facilitate the application and evaluation of the proposed scheme. The algorithm employs the average capacitor current and cable resistance to accurately determine the occurrence and location of faults within the DCMG network. Active DER sources (solar PV, wind, utility grid, and batteries) connect to loads via DC–DC converters, cables, relays, and circuit breakers. The method effectively detects the average capacitor current, enabling the identification of internal faults. Faults are classified as external if a set criterion is not met. Furthermore, the paper proposes a redundancy-based isolation configuration for zonal-type distributed networks. The efficacy of the methodology is rigorously validated through digital simulation studies. MATLAB/Simulink simulations of a DCMG, incorporating diverse generation sources and loads, are conducted under various fault scenarios. These include internal and external faults, as well as Line-to-Ground (LG) and Line-to-Line (LL) faults. The simulation results demonstrate the method’s ability to accurately detect both Low-Impedance Faults (LIFs) and High-Impedance Faults (HIFs) and to locate the faulty cable. Notably, the approach achieves fault cable detection and isolation within 2.3 ms, confirming its effectiveness and speed.
- Open Access
- 25 August 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-30
Optimized fault detection and control for enhanced reliability and efficiency in DC microgrids
This paper introduces a comprehensive framework for fault detection and control in DC microgrids (DCMGs) integrating diverse energy sources. A resistance-based fault detection scheme is proposed to address intermittent DC link faults, enabling efficient operation without complete system shutdown. Perturb and Observe (P&O) techniques are employed for PV and wind power tracking, while proportional-integral (PI) controllers manage fuel cell (FC) and battery energy storage systems (BESS). Fuzzy logic controllers (FLCs) demonstrate superior performance over traditional PI controllers in mitigating voltage and current (V-I) fluctuations. To optimize DC-link V-I levels, a genetic algorithm-tuned PI controller (GA-PIC) and evolution-inspired PI controller are utilized. The proposed method is validated using Opal-RT simulations under various scenarios, demonstrating improved performance over un-optimized configurations. The key achievement of this research is a validated, optimized control and protection scheme that significantly enhances the stability and reliability of DCMGs under fault conditions. Specifically, the work develops a distributed fault detection and control method to improve protection and address stability and power quality in DCMGs. It also presents a GA-based PI-optimized controller for DCMGs with FC and battery storage, and an optimized controller integrating FLCs and GA-tuned PI-Cs to reduce V-I fluctuations. Furthermore, an integrated DC protection scheme is implemented, demonstrating enhanced fault detection speed and accuracy compared to individual schemes. The effectiveness of the proposed GA-PI-C is validated through Opal RT real-time simulations, confirming the efficacy of FLCs in dynamic system responses and contributing to more robust and reliable DCMG operation.
- 25 August 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-30
Open AccessOptimized fault detection and control for enhanced reliability and efficiency in DC microgrids
This paper introduces a comprehensive framework for fault detection and control in DC microgrids (DCMGs) integrating diverse energy sources. A resistance-based fault detection scheme is proposed to address intermittent DC link faults, enabling efficient operation without complete system shutdown. Perturb and Observe (P&O) techniques are employed for PV and wind power tracking, while proportional-integral (PI) controllers manage fuel cell (FC) and battery energy storage systems (BESS). Fuzzy logic controllers (FLCs) demonstrate superior performance over traditional PI controllers in mitigating voltage and current (V-I) fluctuations. To optimize DC-link V-I levels, a genetic algorithm-tuned PI controller (GA-PIC) and evolution-inspired PI controller are utilized. The proposed method is validated using Opal-RT simulations under various scenarios, demonstrating improved performance over un-optimized configurations. The key achievement of this research is a validated, optimized control and protection scheme that significantly enhances the stability and reliability of DCMGs under fault conditions. Specifically, the work develops a distributed fault detection and control method to improve protection and address stability and power quality in DCMGs. It also presents a GA-based PI-optimized controller for DCMGs with FC and battery storage, and an optimized controller integrating FLCs and GA-tuned PI-Cs to reduce V-I fluctuations. Furthermore, an integrated DC protection scheme is implemented, demonstrating enhanced fault detection speed and accuracy compared to individual schemes. The effectiveness of the proposed GA-PI-C is validated through Opal RT real-time simulations, confirming the efficacy of FLCs in dynamic system responses and contributing to more robust and reliable DCMG operation.
- 29 March 2025
- Published by Springer Nature
- p. 47-61
Brushless DC Motor Driving System Design for an Electric Vehicle
- 29 March 2025
- Published by Springer Nature
- p. 47-61
Brushless DC Motor Driving System Design for an Electric Vehicle
- Open Access
- 6 September 2024
- Published by Springer Nature in Research Square
Optimized Fault Detection and Control for Enhanced Reliability and Efficiency in DC Microgrids
This paper presents a comprehensive framework for fault detection, control, and operation within a DC microgrid (DCMG) incorporating diverse energy sources like wind, solar photovoltaic (PV), battery energy storage systems (BESS), utility grid, fuel cells (FC), and load. The DCMG faces challenges due to intermittent faults in the DC link and the necessity to distinguish between low and high fault levels. A resistance-based fault detection scheme is proposed to address these issues, enabling efficient fault detection without necessitating a complete shutdown of the DCMG. Perturb and Observe (P&O) techniques are employed for PV and wind power tracking, while proportional-integral (PI) controllers are utilized for FC and BESS control. In mitigating voltage and current (V-I) fluctuations, fuzzy logic controllers (FLCs) exhibit superior performance compared to traditional PI methods. For the favorable variation of the DC-link V-I level, the traditional PI controller is tuned with a genetic algorithm (GA-PIC) based optimization technique and evolution-inspired PI controller. Additionally, PI controllers undergo optimization via a genetic algorithm (GA), ensuring adherence to V-I limits. The proposed method to investigate fault responses is validated on test systems developed in the OPAL-RT simulator under different scenarios. It Demonstrates improvements over un-optimized counterparts with optimized configuration. This research advances DCMGs by improving their efficiency, stability, and performance.
- 6 September 2024
- Published by Springer Nature in Research Square
Open AccessOptimized Fault Detection and Control for Enhanced Reliability and Efficiency in DC Microgrids
This paper presents a comprehensive framework for fault detection, control, and operation within a DC microgrid (DCMG) incorporating diverse energy sources like wind, solar photovoltaic (PV), battery energy storage systems (BESS), utility grid, fuel cells (FC), and load. The DCMG faces challenges due to intermittent faults in the DC link and the necessity to distinguish between low and high fault levels. A resistance-based fault detection scheme is proposed to address these issues, enabling efficient fault detection without necessitating a complete shutdown of the DCMG. Perturb and Observe (P&O) techniques are employed for PV and wind power tracking, while proportional-integral (PI) controllers are utilized for FC and BESS control. In mitigating voltage and current (V-I) fluctuations, fuzzy logic controllers (FLCs) exhibit superior performance compared to traditional PI methods. For the favorable variation of the DC-link V-I level, the traditional PI controller is tuned with a genetic algorithm (GA-PIC) based optimization technique and evolution-inspired PI controller. Additionally, PI controllers undergo optimization via a genetic algorithm (GA), ensuring adherence to V-I limits. The proposed method to investigate fault responses is validated on test systems developed in the OPAL-RT simulator under different scenarios. It Demonstrates improvements over un-optimized counterparts with optimized configuration. This research advances DCMGs by improving their efficiency, stability, and performance.