Joshua Volin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Joshua Volin has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
Nabile Safdar
Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, Georgia; Vice Chair of Informatics and Associate Chief Medical Information Officer
3 shared publications- Hernan R. Bello
Department of Radiology, Emory University School of Medicine, 1364 Clifton Rd NE, Atlanta, GA 30322
2 shared publications - Luma Abunimer
Department of Radiology, Emory University School of Medicine, 1364 Clifton Rd NE, Atlanta, GA 30322
2 shared publications Peter Harri
Emory Healthcare, Atlanta, GA
2 shared publications- Timothy Arleo
Department of Radiology, Emory University School of Medicine, 1364 Clifton Rd NE, Atlanta, GA 30322
2 shared publications Aarti Sekhar
Department of Radiology, Emory University School of Medicine, 1364 Clifton Rd NE, Atlanta, GA 30322
1 shared publication
Latest Publications
- 1 December 2026
- Published by Radiological Society of North America (RSNA) in RadioGraphics
- Vol. 46 (12)
Gastrointestinal Stromal Tumors: Imaging Findings and a Multidisciplinary Approach to Treatment
Gastrointestinal stromal tumors require a multidisciplinary approach for which molecular diagnostics, targeted therapies, and detailed radiologic assessment are combined to optimize patient outcomes.
- 1 December 2026
- Published by Radiological Society of North America (RSNA) in RadioGraphics
- Vol. 46 (12)
Gastrointestinal Stromal Tumors: Imaging Findings and a Multidisciplinary Approach to Treatment
Gastrointestinal stromal tumors require a multidisciplinary approach for which molecular diagnostics, targeted therapies, and detailed radiologic assessment are combined to optimize patient outcomes.
- 1 June 2026
- Published by Radiological Society of North America (RSNA) in RadioGraphics
- Vol. 46 (6) , e250056
CT Manifestations of HIV-associated Pulmonary Infections and Noninfectious Mimics in the Era of Antiretroviral Therapy
Antiretroviral therapy has transformed treatment of HIV infection from a fatal disease into a chronic condition, yet opportunistic infections remain prevalent in patients with declining CD4 cell counts, requiring a pattern-based radiologic approach and vigilant clinical assessment to differentiate infections, malignancies, and immune reconstitution inflammatory syndrome.
- 1 June 2026
- Published by Radiological Society of North America (RSNA) in RadioGraphics
- Vol. 46 (6) , e250056
CT Manifestations of HIV-associated Pulmonary Infections and Noninfectious Mimics in the Era of Antiretroviral Therapy
Antiretroviral therapy has transformed treatment of HIV infection from a fatal disease into a chronic condition, yet opportunistic infections remain prevalent in patients with declining CD4 cell counts, requiring a pattern-based radiologic approach and vigilant clinical assessment to differentiate infections, malignancies, and immune reconstitution inflammatory syndrome.
- Open Access
- 17 November 2025
- Published by Springer Nature in Journal of Imaging Informatics in Medicine
- Vol. 39 (5) , 4808-4816
Feasibility of Using the Apple Vision Pro for Diagnostic Radiology: User Experience and Perceived Clinical Utility
To assess the feasibility and user experience of spatial computing with Apple Vision Pro (AVP) in medical imaging radiology education. This prospective observational pilot study, approved by the Institutional Review Board and HIPAA-compliant, was conducted at a multisite academic medical center from January to March 2025. Twenty-five radiology physicians (22 diagnostic radiology residents, 2 neuroradiology fellows, 1 neuroradiology attending) participated. After a 5-min setup, participants engaged in a combined structured and self-guided trial of the AVP for clinical applications such as image viewing and electronic health record navigation. Participants completed pre-use and post-use surveys to assess user familiarity, comfort, and perceived utility using 5-point Likert scales. Matched responses were analyzed with Wilcoxon signed-rank tests. Timing data for onboarding and total session duration were recorded. Mean time to device competency was 4.0 ± 1.37 min, and average session time was 14.1 ± 4.94 min. Significant pre-to-post improvements were observed in perceived utility for multidisciplinary conferences ( p = 0.039). The majority rated overall experience and ease of use ≥ 4/5 post-use. Eye strain occurred in 12%; no users reported nausea. Most participants cited ease of use (84%) and efficiency (80%) as key factors influencing future adoption. In this small-scale pilot, the AVP demonstrated strong short-term feasibility and perceived usability for medical imaging among surveyed physician trainees. Results support further investigation of spatial computing in other clinical workflows and medical imaging education.
- 17 November 2025
- Published by Springer Nature in Journal of Imaging Informatics in Medicine
- Vol. 39 (5) , 4808-4816
Open AccessFeasibility of Using the Apple Vision Pro for Diagnostic Radiology: User Experience and Perceived Clinical Utility
To assess the feasibility and user experience of spatial computing with Apple Vision Pro (AVP) in medical imaging radiology education. This prospective observational pilot study, approved by the Institutional Review Board and HIPAA-compliant, was conducted at a multisite academic medical center from January to March 2025. Twenty-five radiology physicians (22 diagnostic radiology residents, 2 neuroradiology fellows, 1 neuroradiology attending) participated. After a 5-min setup, participants engaged in a combined structured and self-guided trial of the AVP for clinical applications such as image viewing and electronic health record navigation. Participants completed pre-use and post-use surveys to assess user familiarity, comfort, and perceived utility using 5-point Likert scales. Matched responses were analyzed with Wilcoxon signed-rank tests. Timing data for onboarding and total session duration were recorded. Mean time to device competency was 4.0 ± 1.37 min, and average session time was 14.1 ± 4.94 min. Significant pre-to-post improvements were observed in perceived utility for multidisciplinary conferences ( p = 0.039). The majority rated overall experience and ease of use ≥ 4/5 post-use. Eye strain occurred in 12%; no users reported nausea. Most participants cited ease of use (84%) and efficiency (80%) as key factors influencing future adoption. In this small-scale pilot, the AVP demonstrated strong short-term feasibility and perceived usability for medical imaging among surveyed physician trainees. Results support further investigation of spatial computing in other clinical workflows and medical imaging education.
- 15 July 2025
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 22 (11) , 1264-1270
Artificial Intelligence and Its Effect on Radiology Residency Education: Current Challenges, Opportunities, and Future Directions
- 15 July 2025
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 22 (11) , 1264-1270
Artificial Intelligence and Its Effect on Radiology Residency Education: Current Challenges, Opportunities, and Future Directions
- 7 June 2025
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 22 (10) , 1132-1140
Best Practices in Cybersecurity Governance: Safeguarding Radiology
- 7 June 2025
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 22 (10) , 1132-1140
Best Practices in Cybersecurity Governance: Safeguarding Radiology
- 7 June 2025
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 22 (11) , 1290-1298
Creating the Next Generation of Education Leaders Through Resident and Fellow Leadership Training
- 7 June 2025
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 22 (11) , 1290-1298
Creating the Next Generation of Education Leaders Through Resident and Fellow Leadership Training
- 3 March 2025
- Published by Springer Nature in Journal of Imaging Informatics in Medicine
- Vol. 38 (6) , 3435-3443
Utilization of an Electronic Health Record Embedded Enterprise Health Data Exchange: A Single Institute Experience
Evaluate the demand, volume, and institutional utilization of an EHR‐based platform for health data exchange in a single US academic system. A retrospective review (3/2023–4/2024) spanned 11 hospitals and over 500 outpatient sites. Analytic reports from the Epic Care Everywhere Image Exchange Advanced Platform (Verona, WI) captured inbound (requested internally) and outbound (accessed externally) data volumes, including thumbnails and subsequent reference‐quality key image retrievals. Data types were categorized as DICOM or non‐DICOM (e.g., JPG, PDF). Counts, retrieval rates, and geographic patterns were analyzed. Inbound data involved 1.6 million patients from 370 external organizations, generating 5% for DICOM and 3% for non‐DICOM; 77% of inbound thumbnails originated in‐state. From 3/2023 to 4/2024, 1.9 million outbound thumbnails were accessed by 1478 external institutions, with a 78% reference-quality key image retrieval rate. Most outbound thumbnails were non‐DICOM (66%); however, overall DICOM retrieval rates (5%) were higher than non-DICOM (3%). In‐state institutions retrieved the most thumbnails (1,156,896/59%), whereas out‐of‐state sites requested more reference-quality key images (1,034,614/67%). Top users included various private and public health sectors. Findings show a growing reliance on EHR‐embedded health data exchange. The abundance of inbound non‐DICOM underscores interoperability challenges, while high DICOM retrieval rates emphasize clinical importance. Geographic disparities highlight the need for standardized solutions to improve continuity of care. Moreover, the upcoming HTI‐2 bill mandates stronger data exchange measures, reinforcing the urgency for scalability. Health data exchange is in high demand as patients increasingly seek care across the US.
- 3 March 2025
- Published by Springer Nature in Journal of Imaging Informatics in Medicine
- Vol. 38 (6) , 3435-3443
Utilization of an Electronic Health Record Embedded Enterprise Health Data Exchange: A Single Institute Experience
Evaluate the demand, volume, and institutional utilization of an EHR‐based platform for health data exchange in a single US academic system. A retrospective review (3/2023–4/2024) spanned 11 hospitals and over 500 outpatient sites. Analytic reports from the Epic Care Everywhere Image Exchange Advanced Platform (Verona, WI) captured inbound (requested internally) and outbound (accessed externally) data volumes, including thumbnails and subsequent reference‐quality key image retrievals. Data types were categorized as DICOM or non‐DICOM (e.g., JPG, PDF). Counts, retrieval rates, and geographic patterns were analyzed. Inbound data involved 1.6 million patients from 370 external organizations, generating 5% for DICOM and 3% for non‐DICOM; 77% of inbound thumbnails originated in‐state. From 3/2023 to 4/2024, 1.9 million outbound thumbnails were accessed by 1478 external institutions, with a 78% reference-quality key image retrieval rate. Most outbound thumbnails were non‐DICOM (66%); however, overall DICOM retrieval rates (5%) were higher than non-DICOM (3%). In‐state institutions retrieved the most thumbnails (1,156,896/59%), whereas out‐of‐state sites requested more reference-quality key images (1,034,614/67%). Top users included various private and public health sectors. Findings show a growing reliance on EHR‐embedded health data exchange. The abundance of inbound non‐DICOM underscores interoperability challenges, while high DICOM retrieval rates emphasize clinical importance. Geographic disparities highlight the need for standardized solutions to improve continuity of care. Moreover, the upcoming HTI‐2 bill mandates stronger data exchange measures, reinforcing the urgency for scalability. Health data exchange is in high demand as patients increasingly seek care across the US.