EHErica Denise Happe
Erica Denise Happe
*This is an algorithmically generated author record based on publicly available information.
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Erica Denise Happe has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Erica Cassie
The MacDiarmid Institute for Advanced Materials and Nanotechnology, Victoria University of Wellington, Wellington 6021, New Zealand
1 shared publication - Hamish Dunham
School of Biological Sciences, Victoria University of Wellington, Wellington, New Zealand
1 shared publication Hong Phan T. Nguyen
School of Chemical and Physics Sciences, Victoria University of Wellington, Wellington, New Zealand
1 shared publication- Janet L. Pitman
The School of Biological Sciences, Te Herenga Waka Victoria University of Wellington, Wellington 6012, New Zealand
1 shared publication - Natalie Olivia Victoria Plank
School of Chemical and Physical Sciences, Victoria University of Wellington, Wellington 6021, New Zealand
1 shared publication
Latest Publications
- Open Access
- 2 October 2023
- Published by Royal Society of Chemistry (RSC) in Sensors & Diagnostics
- Vol. 2 (6) , 1561-1573
A comparison between oestradiol aptamers as receptors in CNT FET biosensors
Point of care tests for measuring the concentration of small molecules such as oestradiol are both highly desirable for healthcare and challenging to design. Field effect transistors functionalised with DNA aptamers, FET aptasensors, are a promising candidate for such tests, however, the performance of FET aptasensors does not consistently keep pace with the performance of particular aptamers in isolation. To better understand the cause of this discrepancy, we compare the performance of two oestradiol aptamers in carbon nanotube network FET aptasensors, and further characterise these aptamers using circular dichroism spectroscopy. We show that both aptamers work effectively as sensors at a much higher analyte concentration, $10^{-6}$ M, than would be predicted by published $K_d$ values, approximately $10^{-8}$ M. We show qualitatively different behaviour between otherwise identical sensors based on the aptamer they are functionalised with, at analyte concentrations well below the limit of detection. Our results suggest that the discrepancy between predicted and realised performance of carbon nanotube network FET aptasensors has two contributing factors: the difference between the ionic environment used for sensing and the environment the aptamers have been characterised in, and the use of SELEX methods that produce aptamers with minimal structure shift on binding. To optimise the sensing response from FET aptasensors, aptamers should be selected for large structure shifts upon binding, and so that they exhibit strong binding in the ionic environment that will be used for sensing.- 2 October 2023
- Published by Royal Society of Chemistry (RSC) in Sensors & Diagnostics
- Vol. 2 (6) , 1561-1573
Open AccessA comparison between oestradiol aptamers as receptors in CNT FET biosensors
Point of care tests for measuring the concentration of small molecules such as oestradiol are both highly desirable for healthcare and challenging to design. Field effect transistors functionalised with DNA aptamers, FET aptasensors, are a promising candidate for such tests, however, the performance of FET aptasensors does not consistently keep pace with the performance of particular aptamers in isolation. To better understand the cause of this discrepancy, we compare the performance of two oestradiol aptamers in carbon nanotube network FET aptasensors, and further characterise these aptamers using circular dichroism spectroscopy. We show that both aptamers work effectively as sensors at a much higher analyte concentration, $10^{-6}$ M, than would be predicted by published $K_d$ values, approximately $10^{-8}$ M. We show qualitatively different behaviour between otherwise identical sensors based on the aptamer they are functionalised with, at analyte concentrations well below the limit of detection. Our results suggest that the discrepancy between predicted and realised performance of carbon nanotube network FET aptasensors has two contributing factors: the difference between the ionic environment used for sensing and the environment the aptamers have been characterised in, and the use of SELEX methods that produce aptamers with minimal structure shift on binding. To optimise the sensing response from FET aptasensors, aptamers should be selected for large structure shifts upon binding, and so that they exhibit strong binding in the ionic environment that will be used for sensing.