Lorenzo Loi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Lorenzo Loi has a total of 698 co-authors. Here are the top co-authors by number of shared publications:
- Antonio Cammi
Politecnico di Milano
5 shared publications - Alberto Garfagnini
INFN Sezione di Padova
4 shared publications - Alessandro Paoloni
INFN, Laboratori Nazionali di Frascati
4 shared publications - Andrea Barresi
INFN, Sezione di Milano Bicocca e Dipartimento di Fisica, Università di Milano Bicocca, Milan
4 shared publications - Andrea Serafini
INFN Sezione di Padova
4 shared publications - Antonio Budano
The Belle II Collaboration)
4 shared publications
Latest Publications
- Open Access
- 1 September 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (09) , P09046
Real-Time Wiener Deconvolution for feature reconstruction in JUNO
In particle physics, experiments generate substantial amounts of data that can be difficult to process without preliminary scaling. To avoid losing potentially crucial data, experimental collaborations are studying novel techniques for real-time data processing to extract features for further physics analysis. A common approach, especially in neutrino physics, is to use FPGAs for data acquisition and pre-processing. This paper presents an advanced Real-Time Wiener deconvolution algorithm designed to leverage the processing capabilities of the FPGA integrated into the readout boards of the Jiangmen Underground Neutrino Observatory (JUNO). The goal is to enable real-time reconstruction of the signal generated by photomultiplier tubes (PMTs) when neutrino interactions are detected. By exploiting online reconstruction of the signal generated by PMTs, we expect to improve the detection of low-energy depositions, such as those produced by transient astrophysical phenomena. These depositions are usually not saved because of the significant background that affects the low end of the energy spectrum, which would result in a large trigger rate, hence a large amount of data required for storage. This paper presents the features of the algorithm, including its ability to manage high-throughput data streams with minimal latency, adaptability, and resilience in discerning the characteristics of input data. Performance is evaluated on a JUNO electronic board. This study further demonstrates the potential of FPGA-based solutions for neutrino physics.
- 1 September 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (09) , P09046
Open AccessReal-Time Wiener Deconvolution for feature reconstruction in JUNO
In particle physics, experiments generate substantial amounts of data that can be difficult to process without preliminary scaling. To avoid losing potentially crucial data, experimental collaborations are studying novel techniques for real-time data processing to extract features for further physics analysis. A common approach, especially in neutrino physics, is to use FPGAs for data acquisition and pre-processing. This paper presents an advanced Real-Time Wiener deconvolution algorithm designed to leverage the processing capabilities of the FPGA integrated into the readout boards of the Jiangmen Underground Neutrino Observatory (JUNO). The goal is to enable real-time reconstruction of the signal generated by photomultiplier tubes (PMTs) when neutrino interactions are detected. By exploiting online reconstruction of the signal generated by PMTs, we expect to improve the detection of low-energy depositions, such as those produced by transient astrophysical phenomena. These depositions are usually not saved because of the significant background that affects the low end of the energy spectrum, which would result in a large trigger rate, hence a large amount of data required for storage. This paper presents the features of the algorithm, including its ability to manage high-throughput data streams with minimal latency, adaptability, and resilience in discerning the characteristics of input data. Performance is evaluated on a JUNO electronic board. This study further demonstrates the potential of FPGA-based solutions for neutrino physics.
- Open Access
- 9 May 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (5)
Ultra-trace analysis of U and Th in organic liquid scintillators with high sensitivity
Rare event searches demand extremely low background levels, necessitating ever-advancing screening techniques to enhance sensitivity. Liquid scintillators are highly attractive as detector media due to their inherent radiopurity and scalability in mass. In this work, we present a screening procedure to measure ultra-trace concentrations of natural contaminants – $$^{238}$$ U and $$^{232}$$ Th – with sensitivities at the $${10}^{-15}$$ g/g level. Our method combines neutron activation analysis with radiochemical techniques, followed by $$\beta $$ / $$\gamma $$ coincidence spectroscopy to minimize interference backgrounds. This approach achieves sensitivities of $$0.65 \cdot 10^{-15}$$ g/g for $$^{238}$$ U and $$1.9 \cdot 10^{-15}$$ g/g for $$^{232}$$ Th, among the best reported worldwide. Potential pathways for further sensitivity improvements are outlined in the conclusions.- 9 May 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (5)
Open AccessUltra-trace analysis of U and Th in organic liquid scintillators with high sensitivity
Rare event searches demand extremely low background levels, necessitating ever-advancing screening techniques to enhance sensitivity. Liquid scintillators are highly attractive as detector media due to their inherent radiopurity and scalability in mass. In this work, we present a screening procedure to measure ultra-trace concentrations of natural contaminants – $$^{238}$$ U and $$^{232}$$ Th – with sensitivities at the $${10}^{-15}$$ g/g level. Our method combines neutron activation analysis with radiochemical techniques, followed by $$\beta $$ / $$\gamma $$ coincidence spectroscopy to minimize interference backgrounds. This approach achieves sensitivities of $$0.65 \cdot 10^{-15}$$ g/g for $$^{238}$$ U and $$1.9 \cdot 10^{-15}$$ g/g for $$^{232}$$ Th, among the best reported worldwide. Potential pathways for further sensitivity improvements are outlined in the conclusions. - Open Access
- 30 September 2025
- Published by Springer Nature in The European Physical Journal C
- Vol. 85 (9) , 1-21
Simulation of the background from $^{13}$C$(\alpha ,\,n)^{16}$O reaction in the JUNO scintillatorLarge-scale organic liquid scintillator detectors are highly efficient in the detection of MeV-scale electron antineutrinos. These signal events can be detected through inverse beta decay on protons, which produce a positron accompanied by a neutron. A noteworthy background for antineutrinos coming from nuclear power reactors and from the depths of the Earth (geoneutrinos) is generated by ( $$\alpha ,\,n$$ ) reactions. In organic liquid scintillator detectors, $$\alpha $$ particles emitted from intrinsic contaminants such as $$^{238}$$ U, $$^{232}$$ Th, and $$^{210}$$ Pb/ $$^{210}$$ Po, can be captured on $$^{13}$$ C nuclei, followed by the emission of a MeV-scale neutron. Three distinct interaction mechanisms can produce prompt energy depositions preceding the delayed neutron capture, leading to a pair of events correlated in space and time within the detector. Thus, ( $$\alpha ,\,n$$ ) reactions represent an indistinguishable background in liquid scintillator-based antineutrino detectors, where their expected rate and energy spectrum are typically evaluated via Monte Carlo simulations. This work presents results from the open-source SaG4n software, used to calculate the expected energy depositions from the neutron and any associated de-excitation products. Also simulated is a detailed detector response to these interactions, using a dedicated Geant4-based simulation software from the JUNO experiment. An expected measurable $$^{13}$$ C $$(\alpha ,\,n)^{16}$$ O event rate and reconstructed prompt energy spectrum with associated uncertainties, are presented in the context of JUNO, however, the methods and results are applicable and relevant to other organic liquid scintillator neutrino detectors.- 30 September 2025
- Published by Springer Nature in The European Physical Journal C
- Vol. 85 (9) , 1-21
Open AccessSimulation of the background from $^{13}$C$(\alpha ,\,n)^{16}$O reaction in the JUNO scintillatorLarge-scale organic liquid scintillator detectors are highly efficient in the detection of MeV-scale electron antineutrinos. These signal events can be detected through inverse beta decay on protons, which produce a positron accompanied by a neutron. A noteworthy background for antineutrinos coming from nuclear power reactors and from the depths of the Earth (geoneutrinos) is generated by ( $$\alpha ,\,n$$ ) reactions. In organic liquid scintillator detectors, $$\alpha $$ particles emitted from intrinsic contaminants such as $$^{238}$$ U, $$^{232}$$ Th, and $$^{210}$$ Pb/ $$^{210}$$ Po, can be captured on $$^{13}$$ C nuclei, followed by the emission of a MeV-scale neutron. Three distinct interaction mechanisms can produce prompt energy depositions preceding the delayed neutron capture, leading to a pair of events correlated in space and time within the detector. Thus, ( $$\alpha ,\,n$$ ) reactions represent an indistinguishable background in liquid scintillator-based antineutrino detectors, where their expected rate and energy spectrum are typically evaluated via Monte Carlo simulations. This work presents results from the open-source SaG4n software, used to calculate the expected energy depositions from the neutron and any associated de-excitation products. Also simulated is a detailed detector response to these interactions, using a dedicated Geant4-based simulation software from the JUNO experiment. An expected measurable $$^{13}$$ C $$(\alpha ,\,n)^{16}$$ O event rate and reconstructed prompt energy spectrum with associated uncertainties, are presented in the context of JUNO, however, the methods and results are applicable and relevant to other organic liquid scintillator neutrino detectors. - Open Access
- 15 July 2025
- Published by Elsevier in Annals of Nuclear Energy
- Vol. 224
Enhancing multi-physics modeling in new-generation nuclear reactors using machine learning: Implementing Gaussian Process Regression for updating cross sections
- 15 July 2025
- Published by Elsevier in Annals of Nuclear Energy
- Vol. 224
Open AccessEnhancing multi-physics modeling in new-generation nuclear reactors using machine learning: Implementing Gaussian Process Regression for updating cross sections
- Open Access
- 25 June 2025
- Published by Elsevier in Nuclear Engineering and Design
- Vol. 442
Photonuclear treatment for spent fuel radiotoxicity reduction: a case study investigation on minor actinides
- 25 June 2025
- Published by Elsevier in Nuclear Engineering and Design
- Vol. 442
Open AccessPhotonuclear treatment for spent fuel radiotoxicity reduction: a case study investigation on minor actinides
- Open Access
- 1 May 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (05) , P05009
Fluorescence emission of the JUNO liquid scintillator
JUNO is a huge neutrino detector that will use 20 kton of organic liquid scintillator as its detection medium. The scintillator is a mixture of linear alkyl benzene (LAB), 2.5 g/L of 2,5-diphenyloxazole (PPO) and 3 mg/L of 1,4-Bis(2-methylstyryl)benzene (Bis-MSB). The main goal of JUNO is to determine the Neutrino Mass Ordering [1,2,3]. In order to achieve this purpose, good energy and position reconstruction is required, hence a complete understanding of the optical characteristics of the liquid scintillator is mandatory. In this paper we present the first measurements on the JUNO scintillator emission spectrum, absorption length and fluorescence time distribution performed respectively with a spectrofluorimeter, a spectrophotometer and a custom made setup of the liquid scintillator produced by the JUNO purification plants.
- 1 May 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (05) , P05009
Open AccessFluorescence emission of the JUNO liquid scintillator
JUNO is a huge neutrino detector that will use 20 kton of organic liquid scintillator as its detection medium. The scintillator is a mixture of linear alkyl benzene (LAB), 2.5 g/L of 2,5-diphenyloxazole (PPO) and 3 mg/L of 1,4-Bis(2-methylstyryl)benzene (Bis-MSB). The main goal of JUNO is to determine the Neutrino Mass Ordering [1,2,3]. In order to achieve this purpose, good energy and position reconstruction is required, hence a complete understanding of the optical characteristics of the liquid scintillator is mandatory. In this paper we present the first measurements on the JUNO scintillator emission spectrum, absorption length and fluorescence time distribution performed respectively with a spectrofluorimeter, a spectrophotometer and a custom made setup of the liquid scintillator produced by the JUNO purification plants.