Sarra Kitanou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sarra Kitanou has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
Azzedine Elmidaoui
Laboratory of Advanced Materials and Process Engineering, Faculty of Sciences, Ibn Tofail University, Kenitra, Morocco
2 shared publications- Fatima Zahra Addar
Laboratory of Advanced Materials and Process Engineering, Faculty of Sciences, Ibn Tofail University, P.O. Box: 1246, Kenitra, Morocco
1 shared publication Idrisse Mohamed
Laboratory of Advanced Materials and Process Engineering, Faculty of Sciences, IbnTofail University, P.O. Box 1246, Kenitra, Morocco
1 shared publicationMohamed Taky
Laboratory of Advanced Materials and Process Engineering, Faculty of Sciences, Ibn Tofail University, Kenitra, Morocco
1 shared publication- Mohamed Taky
Laboratory of Advanced Materials and Process Engineering, Faculty of Sciences, Ibn Tofail University, Kenitra P.O. Box 1246, Morocco
1 shared publication Mustapha Tahaikt
Laboratory of Advanced Materials and Process Engineering, Faculty of Sciences, Ibn Tofail University, Kenitra, Morocco
1 shared publication
Latest Publications
- Open Access
- 28 February 2025
- Published by IWA Publishing in Water Science & Technology
- Vol. 91 (5) , 453-468
Response surface methodology to investigate the effects of operational parameters on membrane bioreactor
Performance modeling of wastewater treatment systems has now become an attractive area of investigation for the design, analysis, and optimization of operations. Mathematical modeling of membrane bioreactor (MBR) treatment is a powerful tool for predicting effluent quality. In this study, a bioreactor coupled with a membrane filtration process (MBR) was employed to treat municipal wastewater. An experimental design based on the response surface methodology (RSM) was applied to investigate the effects of operating conditions, such as hydraulic retention time (HRT), aeration rate (AR), and transmembrane pressure (TMP), on the removal efficiencies of chemical oxygen demand (COD), total suspended solids (TSS), and total nitrogen (TN). The results demonstrated a strong agreement between experimental data and model predictions. Furthermore, the RSM results display the effects of the operating parameters and their interactive effects on pollution removal. The maximum removal efficiency was achieved, exhibiting 95% of COD, 99.7% of TSS, and 93% of TN. These findings provide the effective use of statistical modeling to enhance MBR process performance, achieving sustainable and energy-efficient conditions.
- 28 February 2025
- Published by IWA Publishing in Water Science & Technology
- Vol. 91 (5) , 453-468
Open AccessResponse surface methodology to investigate the effects of operational parameters on membrane bioreactor
Performance modeling of wastewater treatment systems has now become an attractive area of investigation for the design, analysis, and optimization of operations. Mathematical modeling of membrane bioreactor (MBR) treatment is a powerful tool for predicting effluent quality. In this study, a bioreactor coupled with a membrane filtration process (MBR) was employed to treat municipal wastewater. An experimental design based on the response surface methodology (RSM) was applied to investigate the effects of operating conditions, such as hydraulic retention time (HRT), aeration rate (AR), and transmembrane pressure (TMP), on the removal efficiencies of chemical oxygen demand (COD), total suspended solids (TSS), and total nitrogen (TN). The results demonstrated a strong agreement between experimental data and model predictions. Furthermore, the RSM results display the effects of the operating parameters and their interactive effects on pollution removal. The maximum removal efficiency was achieved, exhibiting 95% of COD, 99.7% of TSS, and 93% of TN. These findings provide the effective use of statistical modeling to enhance MBR process performance, achieving sustainable and energy-efficient conditions.
- Open Access
- 27 December 2023
- Published by IWA Publishing in Water Science & Technology
- Vol. 89 (1) , 132-145
Performance of three anion-exchange membranes in fluoride ions removal by electrodialysis
The performance of three anion-exchange membranes (AEMs) in the fluoride ions reduction by electrodialysis (ED) is performed on real and synthetic water. The electric potential method measures the potential difference (PD) between two synthetic anion solutions separated by ACS, AFN and AXE membranes. The selectivity of these three AEMs coupled with the membrane CMX, is a cation-exchange membrane (CEM) towards different ions. The removal rate is influenced by the thickness of the polarization layer (PL) which reduces the material transfer and provides an additional barrier. The greater the thickness δ of the PL, the longer the passage time and consequently the removal rate of anions is small. Using the unstirred layer model, δ for each ion will be determined. According to the potential measurement method, none of the tested AEMs are selective to fluoride ions and the order of selectivity is as follows: AFN> AXE> ACS. Best membrane couple selected for fluoride ion removal is ACS/CMX and ion selectivity follows the order: Cl−> NO−3>F−> HCO−3> SO42−. For ACS membrane, both the demineralization rate (DR) and δ of fluoride ions are influenced by the initial concentration of the co-ion according to the following order: NO−3> Cl−> HCO−3> SO2−4.
- 27 December 2023
- Published by IWA Publishing in Water Science & Technology
- Vol. 89 (1) , 132-145
Open AccessPerformance of three anion-exchange membranes in fluoride ions removal by electrodialysis
The performance of three anion-exchange membranes (AEMs) in the fluoride ions reduction by electrodialysis (ED) is performed on real and synthetic water. The electric potential method measures the potential difference (PD) between two synthetic anion solutions separated by ACS, AFN and AXE membranes. The selectivity of these three AEMs coupled with the membrane CMX, is a cation-exchange membrane (CEM) towards different ions. The removal rate is influenced by the thickness of the polarization layer (PL) which reduces the material transfer and provides an additional barrier. The greater the thickness δ of the PL, the longer the passage time and consequently the removal rate of anions is small. Using the unstirred layer model, δ for each ion will be determined. According to the potential measurement method, none of the tested AEMs are selective to fluoride ions and the order of selectivity is as follows: AFN> AXE> ACS. Best membrane couple selected for fluoride ion removal is ACS/CMX and ion selectivity follows the order: Cl−> NO−3>F−> HCO−3> SO42−. For ACS membrane, both the demineralization rate (DR) and δ of fluoride ions are influenced by the initial concentration of the co-ion according to the following order: NO−3> Cl−> HCO−3> SO2−4.