AZAo Zhang

Ao Zhang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ao Zhang has a total of 38 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Analytical Sampling Bounds and Hexagonal Topology for Magnetocardiography Sensor Arrays

    by Ao Zhang, Xu Zhang, Jianzhi Yang, Kangqi Tian, Wenpeng Chen, Qiang Shi Zheng

    Sensor spacing and array topology critically determine the scalability, cost, and reconstruction reliability of magnetocardiography (MCG) systems. However, current design strategies often rely on source-specific metrics or discrete grid searches, lacking a physically interpretable criterion that captures the critical interplay between spatial aliasing, source depth, and measurement noise. Therefore, this paper proposes a physics-driven spatial sampling optimization framework that incorporates realistic measurement noise to establish quantitative criteria for MCG array design. Analytical results reveal that the anti-aliasing upper bound is strictly proportional to the source depth, whereas the engineering lower bound, designed to prevent redundant oversampling, is jointly determined by both the source depth and the logarithm of the spatial equivalent signal-to-noise ratio (SNRgeom). Furthermore, reciprocal space analysis demonstrates that the hexagonal lattice increases spectral packing efficiency from 78.54% to 90.69\%. The geometric advantage directly translates to an approximate 13.4% reduction in the required number of sensing channels under identical anti-aliasing constraints. The proposed theoretical bounds and topological superiority are cross-validated through multi-dipole Monte Carlo simulations and 3D physical phantom experiments. Empirical results exhibit strong agreement with theoretical predictions, demonstrating that the hexagonal layout effectively postpones the onset of spatial aliasing and maintains the reconstruction error below 15%, even under an sparse sampling interval of 60 mm. This framework provides fundamental guidelines for designing high-efficiency, cost-effective MCG sensor arrays.

  • Inverse design of circular self-shielding biplanar coils for miniature atomic sensors

    by Wenpeng Chen, Jianli Li, Zekun Wu, Ao Zhang, Chuanming Yin, Junjie Zhang, Jingsong Wang, Xuelei Wang

  • Magnetocardiography System With Self-Shielding Coils for High-Quality Cardiac Magnetic Signal Acquisition

    by Ao Zhang, Xu Zhang, Minxia Shi, Jianzhi Yang, Leran Zhang, Kangqi Tian, Ziyang Shi, Wenpeng Chen, Shiqiang Zheng

    To establish a near-zero magnetic environment for accurate magnetocardiography (MCG) measurements, a magnetically shielded cylinder (MSC) is commonly used in combination with active magnetic compensation coils. However, the coupling effect between the field from internal coils and the magnetic shielding layer can distort the distribution of ideal magnetic field and degrade the quality of cardiac magnetic signals. To address this issue, this article proposes a design approach for self-shielding coils featuring curved structures that integrate the target-field method with the pigeon-inspired optimization algorithm. The results indicate that the optimized coils maintain nonuniformity error below 1% in the internal region with a side length of 0.2 m and attain an attenuation error below 5% in the external area. This means that the coils are not easily affected by ferromagnetic materials and are suitable for MSCs of different sizes. An optically pumped magnetometer-based magnetocardiography (OPM-MCG) system, using two sets of single-axis curved coils, is used to compensate for the background field interference, resulting in an improved signal-to-noise ratio (SNR) for cardiac magnetic signals. Within the frequency range of 1–40 Hz, the average sensitivity of the OPM-MCG compensation system improves from 810.59 to 97.63 $\text{fT/Hz}^{1/2}$ , and it achieves 9.19 dB of noise suppression. Based on the enhanced MCG system, the collected MCG signals reveal significant SNR gains of 6.44 and 5.89 dB in the R-wave and T-wave segments, which lays a foundation for further exploration of cardiac electrophysiological information and assisted cardiac treatment.


  • Design of Highly Uniform Axial Magnetic Field Coils Within Magnetic Shielding Box for Miniature NMRG Sensors

    by Wenpeng Chen, Jianli Li, Xuelei Wang, Chuanming Yin, Ao Zhang, Junjie Zhang

    The uniform magnetic field coils within the magnetic shielding layer find numerous applications, particularly in miniature NMRG sensors. However, the target magnetic field generated by the designed coils is inevitably distorted due to the adjacent ferromagnetic material that attracts the magnetic field. To address this issue, a novel image method based on uniqueness principle is proposed, which takes into account the coupling effect between the magnetic shielding box (MSB) and the coils. The particle swarm optimization (PSO) algorithm is employed to assist the novel image method in designing highly uniform axial magnetic field coils within a compact MSB. The validity and uniformity of the designed coils are verified by the finite element method (FEM), demonstrating the maximum relative uniformity error of magnetic flux density Bz is 2.6×10−4 compared to the original point. Moreover, two classic configurations of uniform magnetic field coils, the Helmholtz coils and the 9449 coils, are introduced to compare the uniformity with the designed coils. Finally, the designed scheme was measured both within and without MSB and the experimental results indicated that the relative uniformity error of Bz was in good agreement with the reference values. These findings further substantiate the applicability of the proposed method to miniature atomic sensors that require generating a highly uniform magnetic field within the MSB.


  • Advanced Simulation and Measurement of the Magnetocardiography Forward Problem Based on a Novel Electromagnetic Conversion Analytical Model

    by Kangqi Tian, Xu Zhang, Jianzhi Yang, Yuqing Hu, Ao Zhang, Min Xiang, Shiqiang Zheng, Gang Liu

    In the electrophysiological study of ischemic chronic heart failure (I-CHF) patients, cardiac electrical activity is captured using body surface electrodes in traditional electrocardiography (ECG). However, due to its limited spatial resolution, surface potential changes are reflected by ECG, and deep cardiac electrophysiological signals are struggled to be accurately detected, especially under complex pathological conditions. To address this limitation, a forward problem analytical model based on a three-dimensional cardiac-torso model for magnetocardiography (MCG) is proposed. An individualized ventricular-torso dual-domain model is constructed, and an improved diffusion equation is employed to accurately simulate the potential distribution between the endocardium and epicardium in I-CHF patients. The dynamic characteristics of the three-dimensional equivalent current density within cardiac tissue are analyzed. The simulated three-dimensional potential distribution is converted into a body surface magnetic field distribution and compared with MCGs obtained using a spin-exchange relaxation-free (SERF) magnetometer array. The proposed electromagnetic conversion analytical model demonstrates improvements in accuracy. At the peak moments of the R-wave and T-wave, significant differences in SSIM values are observed between normal individuals and ICHF patients. SSIM values for normal individuals are higher (R-wave 0.9066, T-wave 0.8537) compared to I-CHF patients (R-wave 0.8135, T-wave 0.8231). The simulated and measured data for the healthy group are consistent, while for the I-CHF group, the simulated gain and offset increase from 0.98 and 1.98 to 1.06 and 2.25, and the measured gain and offset decrease from 0.81 and 3.02 to 0.78 and 2.87. These results highlight the model’s ability to differentiate between normal and I-CHF conditions, providing a promising tool for early diagnosis of diseases.


  • A Novel Magnetic Suppression Technique for Asymmetric-Distributed Magnetic Disturbance in CMS for MCG Test

    by Minxia Shi, Leran Zhang, Xu Zhang, Jianzhi Yang, Yuzheng Ma, Ao Zhang, Shuai Yuan

    The cylindrical magnetic shield (CMS) with the advantages of easy process, low cost, and portable mobility is widely utilized in magnetocardiography (MCG) for recording the weak biomagnetic field of cardiac. The one-side-open structure of CMS leads to excessive flux leakage and uneven-distributed magnetic field, which cause extra degradation of sensitivity and signal noise ratio of MCG test. Therefore, an enhanced magnetic suppression technique for reducing the asymmetric-distributed remanence and magnetic noise inside CMS is proposed in this article. This method introduces the Fourier series with half-angle component for asymmetric compensation field generation and combines the analytic method to model and weaken coupling effect impact. The feedback control is employed in the compensation system for static and dynamic magnetic interference containment. The asymmetric-distributed remanence ${B} _{y}$ and $B_{z}$ is suppressed near zero, and the magnetic noise of ${B} _{y}$ and Bz at 0.01 Hz is restrained from 59.3 to 0.06 ${pT/Hz}^{1/2}$ and 92.7–0.24 ${pT/Hz}^{1/2}$ with the inhibition rate of 29.95 and 25.87 dB, respectively. The MCG test with high signal-to-noise ratio is then realized inside the MCS with the asymmetric compensation system.


  • Research on MCGs of Conduction Block Heart Failure Based on Electromagnetic Model of Cardiac Electrophysiological Conduction Pathways

    by Kangqi Tian, Xu Zhang, Min Xiang, Jianzhi Yang, Ao Zhang, Yuqing Hu, Ziyang Shi, Haifeng Zhang, Shiqiang Zheng, Gang Liu

    Ischemic chronic heart failure (ICHF) that is accompanied by bundle-branch block (BBB) represents a complex cardiac electrophysiological abnormality that has a significant impact on cardiac function. Under complex pathological cardiac conditions, signal changes are often insufficiently detected. Owing to the fixed and limited number of electrode placements of the electrocardiogram (ECG) subtle, abnormal, cardiac electrophysiological signals are difficult to capture comprehensively. In contrast, magnetocardiographs (MCGs) measured by spin-exchange relaxation-free (SERF) magnetometers, with their higher sensitivity and spatial resolution, represent cardiac electrical activity more accurately. However, owing to the longer electrical-conduction pathways of the cardiac deep structure and the superimposition of abnormal signals from the BBB-accompanied ICHF, these abnormal signals are weak and capture by SERF magnetometers is difficult; precise identification of the MCG features is thus more challenging. To address these technical limitations and enhance the detection of cardiac electrophysiological abnormalities, a more precise solution is required. In this paper, a comprehensive cardiac electrophysiological-conduction model and simulation method are proposed. Conduction pathways are mathematically modeled, and their contributions to the magnetic field are calculated. Detailed images of cardiac electrical activity are obtained through interpolation of MCGs. More accurate MCG data are generated by solving the comprehensive myocardial current I’total. Simulated MCGs provide new insights for the MCG-technology optimization and highlight the value of cardiac electrophysiological conduction models in MCG measurements, thereby significantly improving the early detection and diagnosis of BBB.


  • A Novel Biplanar Coils Method for Designing a Transverse Uniform Magnetic Field in Miniature Atomic Sensors

    by Wenpeng Chen, Jianli Li, Ao Zhang, Yingwang Fan, Xuelei Wang

    This paper propose a novel and easy-to-implement method that employs a predefined circular configuration for biplanar coils to produce a transverse uniform magnetic field. The coil windings are distributed on the plane within a preset radius range, fulfilling the design criteria of preserving a central light-passing hole, an ideal feature for miniature atomic sensors. Compared to the conventional saddle coil design method, this method can minimize the aspect ratio to unity while maintaining high magnetic field uniformity. Moreover, to further improve the magnetic field uniformity in the target region, the particle swarm optimization (PSO) algorithm is introduced to optimize the regularization coefficient of the coils. Compared with the classic saddle coil structure, the simulation results demonstrate that the proposed method not only reduces the aspect ratio from 2 to 1, but also improves the maximum inhomogeneity relative error from 9.74 × 10−3 to 5.33 × 10−3 in the target region. To verify the accuracy of the results, the quintuple magnification coil scheme was manufactured by printed circuit board (PCB) technology avoiding the error caused by manual winding. Finally, the experimental results confirm that the magnetic field uniformity is nearly consistent with the theoretical analysis results.


  • Open Access

    Evaluation of a polyether-based polycarboxylate as precipitation inhibitor for calcium carbonate and calcium sulfate

    by Ao Zhang, Yuming Zhou, Qingzhao Yao, Tiantian Wang, Jun Li, Yiyi Chen, Jie Pan, Shuang Liang, Qiuli Nan, Mingjue Zhang, et al.