Yusuf Aslan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yusuf Aslan has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Fatih Inci
UNAM—National Nanotechnology Research Center Bilkent University Ankara Turkey
3 shared publications Esma Derin
UNAM − National Nanotechnology Research Center
2 shared publications- Özgecan Erdem
UNAM − National Nanotechnology Research Center
2 shared publications Abdullah Kafadenk
UNAM − National Nanotechnology Research Center
1 shared publicationAli Karatutlu
UNAM − National Nanotechnology Research Center
1 shared publicationBülend Ortaç
UNAM − National Nanotechnology Research Center
1 shared publication
Latest Publications
- Open Access
- 9 February 2026
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 18 (7) , 11774-11784
Spatiotemporal Confinements of Distance-Dependent Emitters for Enhancing Plasmonic Signals
Surface plasmon resonance (SPR) is a common technique used for the real-time tracing of various analytes through refractive index–dependent resonance shifts. However, many plasmonic biosensors do not meet the clinical detection requirements for ultra-low concentration and low refractive index biomarkers. To address this challenge, researchers have explored unique labeling and interface modification strategies. One common strategy is utilizing fluorescence with plasmonic structures and enhancing the fluorescence intensity. However, these studies primarily focused on plasmon-enhanced fluorescence intensity, leaving the influence of fluorophores on reflection-/absorption-based plasmonic resonance shifts unexplored. Herein, we introduce a technique for amplifying the resonance shift of a plasmonic metasurface by confining the interdistance of fluorescence emitters. By adjusting nanospaces (∼4 to 20 nm), we couple surface plasmons with fluorescence in the near-field, achieving interdistance-dependent resonance shift behavior. This approach results in a 4.5-fold signal enhancement in the resonance shift for detecting conjugated proteins from complex matrices. In this regard, we utilize a plasmonic metasurface and distinct fluorescent emitters (FITC, Texas Red, streptavidin-quantum dot (QD) 525, and streptavidin-QD 625) with diverse excitation and emission assets. We also experimentally demonstrate a spectral blue shift of the plasmonic resonance through resonant coupling between QDs and surface plasmons, in contrast to the conventionally observed red shift. To hurdle the cost- and fabrication-related challenges in metasurfaces, we recycle off-the-shelf digital versatile discs (DVDs) into plasmonic metasurfaces due to their intrinsic nanograting structures, thereby significantly minimizing the cost down to $1.5. Moreover, we collect spatiotemporal signals using a palm-sized platform (5 cm × 10 cm x 1 cm) within 15 min that would be easily adapted into any settings possible. Consequently, this strategy paves the way for creating novel configurations and arrangements on a metasurface sensor to couple with fluorescence molecules while boosting the sensor’s analytical performance that would be potentially integrated with biosensing applications in disease diagnostics.
- 9 February 2026
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 18 (7) , 11774-11784
Open AccessSpatiotemporal Confinements of Distance-Dependent Emitters for Enhancing Plasmonic Signals
Surface plasmon resonance (SPR) is a common technique used for the real-time tracing of various analytes through refractive index–dependent resonance shifts. However, many plasmonic biosensors do not meet the clinical detection requirements for ultra-low concentration and low refractive index biomarkers. To address this challenge, researchers have explored unique labeling and interface modification strategies. One common strategy is utilizing fluorescence with plasmonic structures and enhancing the fluorescence intensity. However, these studies primarily focused on plasmon-enhanced fluorescence intensity, leaving the influence of fluorophores on reflection-/absorption-based plasmonic resonance shifts unexplored. Herein, we introduce a technique for amplifying the resonance shift of a plasmonic metasurface by confining the interdistance of fluorescence emitters. By adjusting nanospaces (∼4 to 20 nm), we couple surface plasmons with fluorescence in the near-field, achieving interdistance-dependent resonance shift behavior. This approach results in a 4.5-fold signal enhancement in the resonance shift for detecting conjugated proteins from complex matrices. In this regard, we utilize a plasmonic metasurface and distinct fluorescent emitters (FITC, Texas Red, streptavidin-quantum dot (QD) 525, and streptavidin-QD 625) with diverse excitation and emission assets. We also experimentally demonstrate a spectral blue shift of the plasmonic resonance through resonant coupling between QDs and surface plasmons, in contrast to the conventionally observed red shift. To hurdle the cost- and fabrication-related challenges in metasurfaces, we recycle off-the-shelf digital versatile discs (DVDs) into plasmonic metasurfaces due to their intrinsic nanograting structures, thereby significantly minimizing the cost down to $1.5. Moreover, we collect spatiotemporal signals using a palm-sized platform (5 cm × 10 cm x 1 cm) within 15 min that would be easily adapted into any settings possible. Consequently, this strategy paves the way for creating novel configurations and arrangements on a metasurface sensor to couple with fluorescence molecules while boosting the sensor’s analytical performance that would be potentially integrated with biosensing applications in disease diagnostics.
- Open Access
- 16 October 2025
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 17 (47) , 64048-64064
Spatial Designs on Metamaterial Sensors for Enhancing Signals and Detecting Extracellular Vesicles
Biosensors, while holding immense promise for biomarker detection, face substantial challenges in analytical performance, fabrication intricacies, and complex applications, hindering their seamless integration into point-of-care (POC) settings. Metamaterial-based plasmonic biosensors offer tremendous potential for biomarker detection; however, their widespread adoption in POC diagnostics remains hampered by limitations in sensitivity, fabrication complexity, and production cost. Herein, we introduce, for the first time, in situ-controlled spatial designs on metamaterial-based plasmonic sensors, demonstrating unprecedented sensitivity in detecting extracellular vesicles (EVs). In the fabrication process, commercially available optical disks were repurposed as nanostructured substrates, yielding a cost reduction of up to 260-fold ($0.90 per sensor) and a fabrication time reduction of approximately 960-fold, compared to conventional e-beam lithography. Leveraging inherent nanogratings, measurements are conducted on a compact, palm-sized platform, addressing challenges in usability and portability associated with bulky optical designs. Through ex situ immobilization of gold nanoparticles (AuNPs) or in situ formation of nanoislands (NIs), we have engineered plasmonic hotspots that substantially enhanced local electric field intensities, thereby amplifying the bulk refractive index sensitivity of the sensors. Finite-difference time-domain simulations confirmed that the spatial arrangement and interparticle distances of spatial designs enhance near-field effects. The optimized platform exhibits up to a 5.5-fold enhancement in refractive index sensitivity. Moreover, based on data obtained from nanoparticle tracking analysis (NTA), fluorescence-enhanced NTA (fNTA), and recent literature benchmarks, the platform demonstrated detection limits of 104 particles/μL (as determined by raw NTA measurements), approximately 330 fg/μL (estimated via literature-based EV mass calculations), and 138 EVs/μL (quantified via fNTA using marker-specific labeling). Herein, we anticipate that repurposing disks as metamaterial sensors has the potential to address pressing challenges in usability, portability, cost, and complexity. Besides, 3D configurations on sensors would improve the analytical performance, offering highly sensitive and facile platforms for diverse applications in the future.
- 16 October 2025
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 17 (47) , 64048-64064
Open AccessSpatial Designs on Metamaterial Sensors for Enhancing Signals and Detecting Extracellular Vesicles
Biosensors, while holding immense promise for biomarker detection, face substantial challenges in analytical performance, fabrication intricacies, and complex applications, hindering their seamless integration into point-of-care (POC) settings. Metamaterial-based plasmonic biosensors offer tremendous potential for biomarker detection; however, their widespread adoption in POC diagnostics remains hampered by limitations in sensitivity, fabrication complexity, and production cost. Herein, we introduce, for the first time, in situ-controlled spatial designs on metamaterial-based plasmonic sensors, demonstrating unprecedented sensitivity in detecting extracellular vesicles (EVs). In the fabrication process, commercially available optical disks were repurposed as nanostructured substrates, yielding a cost reduction of up to 260-fold ($0.90 per sensor) and a fabrication time reduction of approximately 960-fold, compared to conventional e-beam lithography. Leveraging inherent nanogratings, measurements are conducted on a compact, palm-sized platform, addressing challenges in usability and portability associated with bulky optical designs. Through ex situ immobilization of gold nanoparticles (AuNPs) or in situ formation of nanoislands (NIs), we have engineered plasmonic hotspots that substantially enhanced local electric field intensities, thereby amplifying the bulk refractive index sensitivity of the sensors. Finite-difference time-domain simulations confirmed that the spatial arrangement and interparticle distances of spatial designs enhance near-field effects. The optimized platform exhibits up to a 5.5-fold enhancement in refractive index sensitivity. Moreover, based on data obtained from nanoparticle tracking analysis (NTA), fluorescence-enhanced NTA (fNTA), and recent literature benchmarks, the platform demonstrated detection limits of 104 particles/μL (as determined by raw NTA measurements), approximately 330 fg/μL (estimated via literature-based EV mass calculations), and 138 EVs/μL (quantified via fNTA using marker-specific labeling). Herein, we anticipate that repurposing disks as metamaterial sensors has the potential to address pressing challenges in usability, portability, cost, and complexity. Besides, 3D configurations on sensors would improve the analytical performance, offering highly sensitive and facile platforms for diverse applications in the future.
- Open Access
- 28 February 2025
- Published by American Chemical Society (ACS) in ACS Applied Nano Materials
- Vol. 8 (10) , 4967-4979
Unveiling Molecular Fingerprints of Bacteria on Nanoplasmonic Sensors
- 28 February 2025
- Published by American Chemical Society (ACS) in ACS Applied Nano Materials
- Vol. 8 (10) , 4967-4979
Open AccessUnveiling Molecular Fingerprints of Bacteria on Nanoplasmonic Sensors