Yoshihisa Muramatsu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yoshihisa Muramatsu has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Hirofumi Kuno
Department of Diagnostic Radiology, National Cancer Center Hospital East, Kashiwa, Japan
2 shared publications Hiroki Taguchi
Canon Medical Systems Corporation, Otawara, Japan
2 shared publications- Tatsushi Kobayashi
Department of Diagnostic Radiology, National Cancer Center Hospital East, Kashiwa, Japan
2 shared publications - Tomoaki Sasaki
Department of Diagnostic Radiology, National Cancer Center Hospital East, Kashiwa, Japan
2 shared publications Eisuke Goto
Department of Thoracic Surgery, National Cancer Center Hospital East, Kashiwa, Japan
1 shared publication- Hideki Furuya
Clinical Research Support Office, National Cancer Center Hospital East, Kashiwa, Japan
1 shared publication
Latest Publications
- Open Access
- 16 October 2025
- Published by Springer Nature in Japanese Journal of Radiology
- Vol. 44 (2) , 221-241
Imaging-detected extranodal extension in head and neck cancer: clinical implications, diagnostic criteria, and the potential of photon-counting detector CT
Imaging-detected extranodal extension (iENE) is increasingly recognized as an objective adverse prognostic factor in head and neck cancer. The newly published 9th edition of the UICC/AJCC TNM Classification now incorporates iENE into the nodal (N) categories for nasopharyngeal carcinoma, HPV-associated oropharyngeal carcinoma, and salivary gland carcinoma, typically upstaging patients to higher N categories, and designates imaging findings as an accepted standard for the clinical ENE (cENE) as the N3b category in all other head and neck subsites. To establish diagnostic criteria for iENE, the Head and Neck Cancer International Group (HNCIG) has proposed a four-tier grading system (2024): Grade 0 (iENE-negative), Grade 1 (perinodal fat extension), Grade 2 (coalescent lymph nodes), and Grade 3 (invasion of adjacent structures). Each grade carries distinct clinical implications, ranging from treatment de-escalation for Grade 0 to consideration of unresectable disease for Grade 3. Recent advances in ultra-high-resolution imaging, particularly photon-counting detector CT (PCD-CT) with 1024 × 1024 matrix in super-high-resolution (SHR) mode, may offer the spatial details necessary to more reliably detect these subtle findings compared with conventional imaging. Through direct comparisons with histopathological correlations, we demonstrate the potential of high-resolution imaging in detecting iENE. PCD-CT, with its simultaneous spectral imaging capabilities—including virtual monochromatic imaging—enhances soft tissue contrast for detecting subtle ENEs. In addition, material decomposition maps aid in the precise evaluation of tumor–tissue interfaces. This comprehensive review is an educational resource for radiologists applying the HNCIG consensus criteria including the newly adopted TNM staging requirements. While advanced imaging technologies such as PCD-CT show promising potential for enhanced tissue characterization, further validation studies are needed to establish their clinical utility in routine iENE assessment.
- 16 October 2025
- Published by Springer Nature in Japanese Journal of Radiology
- Vol. 44 (2) , 221-241
Open AccessImaging-detected extranodal extension in head and neck cancer: clinical implications, diagnostic criteria, and the potential of photon-counting detector CT
Imaging-detected extranodal extension (iENE) is increasingly recognized as an objective adverse prognostic factor in head and neck cancer. The newly published 9th edition of the UICC/AJCC TNM Classification now incorporates iENE into the nodal (N) categories for nasopharyngeal carcinoma, HPV-associated oropharyngeal carcinoma, and salivary gland carcinoma, typically upstaging patients to higher N categories, and designates imaging findings as an accepted standard for the clinical ENE (cENE) as the N3b category in all other head and neck subsites. To establish diagnostic criteria for iENE, the Head and Neck Cancer International Group (HNCIG) has proposed a four-tier grading system (2024): Grade 0 (iENE-negative), Grade 1 (perinodal fat extension), Grade 2 (coalescent lymph nodes), and Grade 3 (invasion of adjacent structures). Each grade carries distinct clinical implications, ranging from treatment de-escalation for Grade 0 to consideration of unresectable disease for Grade 3. Recent advances in ultra-high-resolution imaging, particularly photon-counting detector CT (PCD-CT) with 1024 × 1024 matrix in super-high-resolution (SHR) mode, may offer the spatial details necessary to more reliably detect these subtle findings compared with conventional imaging. Through direct comparisons with histopathological correlations, we demonstrate the potential of high-resolution imaging in detecting iENE. PCD-CT, with its simultaneous spectral imaging capabilities—including virtual monochromatic imaging—enhances soft tissue contrast for detecting subtle ENEs. In addition, material decomposition maps aid in the precise evaluation of tumor–tissue interfaces. This comprehensive review is an educational resource for radiologists applying the HNCIG consensus criteria including the newly adopted TNM staging requirements. While advanced imaging technologies such as PCD-CT show promising potential for enhanced tissue characterization, further validation studies are needed to establish their clinical utility in routine iENE assessment.
- Open Access
- 7 March 2025
- Published by Springer Nature in Japanese Journal of Radiology
- Vol. 43 (7) , 1132-1144
CZT-based photon-counting-detector CT with deep-learning reconstruction: image quality and diagnostic confidence for lung tumor assessment
Purpose: This is a preliminary analysis of one of the secondary endpoints in the prospective study cohort. The aim of this study is to assess the image quality and diagnostic confidence for lung cancer of CT images generated by using cadmium–zinc–telluride (CZT)-based photon-counting-detector-CT (PCD-CT) and comparing these super-high-resolution (SHR) images with conventional normal-resolution (NR) CT images. Materials and methods: Twenty-five patients (median age 75 years, interquartile range 66–78 years, 18 men and 7 women) with 29 lung nodules overall (including two patients with 4 and 2 nodules, respectively) were enrolled to undergo PCD-CT. Three types of images were reconstructed: a 512 × 512 matrix with adaptive iterative dose reduction 3D (AIDR 3D) as the NRAIDR3D image, a 1024 × 1024 matrix with AIDR 3D as the SHRAIDR3D image, and a 1024 × 1024 matrix with deep-learning reconstruction (DLR) as the SHRDLR image. For qualitative analysis, two radiologists evaluated the matched reconstructed series twice (NRAIDR3D vs. SHRAIDR3D and SHRAIDR3D vs. SHRDLR) and scored the presence of imaging findings, such as spiculation, lobulation, appearance of ground-glass opacity or air bronchiologram, image quality, and diagnostic confidence, using a 5-point Likert scale. For quantitative analysis, contrast-to-noise ratios (CNRs) of the three images were compared. Results: In the qualitative analysis, compared to NRAIDR3D, SHRAIDR3D yielded higher image quality and diagnostic confidence, except for image noise (all P < 0.01). In comparison with SHRAIDR3D, SHRDLR yielded higher image quality and diagnostic confidence (all P < 0.01). In the quantitative analysis, CNRs in the modified NRAIDR3D and SHRDLR groups were higher than those in the SHRAIDR3D group (P = 0.003, DLR images provided the highest image quality and diagnostic confidence for lung tumor evaluation, followed by SHRAIDR3D and NRAIDR3D images. DLR demonstrated superior noise reduction compared to other reconstruction methods.
- 7 March 2025
- Published by Springer Nature in Japanese Journal of Radiology
- Vol. 43 (7) , 1132-1144
Open AccessCZT-based photon-counting-detector CT with deep-learning reconstruction: image quality and diagnostic confidence for lung tumor assessment
Purpose: This is a preliminary analysis of one of the secondary endpoints in the prospective study cohort. The aim of this study is to assess the image quality and diagnostic confidence for lung cancer of CT images generated by using cadmium–zinc–telluride (CZT)-based photon-counting-detector-CT (PCD-CT) and comparing these super-high-resolution (SHR) images with conventional normal-resolution (NR) CT images. Materials and methods: Twenty-five patients (median age 75 years, interquartile range 66–78 years, 18 men and 7 women) with 29 lung nodules overall (including two patients with 4 and 2 nodules, respectively) were enrolled to undergo PCD-CT. Three types of images were reconstructed: a 512 × 512 matrix with adaptive iterative dose reduction 3D (AIDR 3D) as the NRAIDR3D image, a 1024 × 1024 matrix with AIDR 3D as the SHRAIDR3D image, and a 1024 × 1024 matrix with deep-learning reconstruction (DLR) as the SHRDLR image. For qualitative analysis, two radiologists evaluated the matched reconstructed series twice (NRAIDR3D vs. SHRAIDR3D and SHRAIDR3D vs. SHRDLR) and scored the presence of imaging findings, such as spiculation, lobulation, appearance of ground-glass opacity or air bronchiologram, image quality, and diagnostic confidence, using a 5-point Likert scale. For quantitative analysis, contrast-to-noise ratios (CNRs) of the three images were compared. Results: In the qualitative analysis, compared to NRAIDR3D, SHRAIDR3D yielded higher image quality and diagnostic confidence, except for image noise (all P < 0.01). In comparison with SHRAIDR3D, SHRDLR yielded higher image quality and diagnostic confidence (all P < 0.01). In the quantitative analysis, CNRs in the modified NRAIDR3D and SHRDLR groups were higher than those in the SHRAIDR3D group (P = 0.003, DLR images provided the highest image quality and diagnostic confidence for lung tumor evaluation, followed by SHRAIDR3D and NRAIDR3D images. DLR demonstrated superior noise reduction compared to other reconstruction methods.