Mingzhu Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mingzhu Chen has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
Baichuan Li
Shanghai Normal University, Shanghai, Shanghai, CHINA
1 shared publicationFeifei Wang
Shanghai Normal University, Shanghai, Shanghai, CHINA
1 shared publicationHaosu Luo
The State Key Laboratory of High Perfomance Ceramics and Superfine Microstructure, Shanghai Institute of Ceramics Chinese Academy of Sciences, Changning District, Shanghai, CHINA
1 shared publicationHuiling Liu
Shanghai Normal University, Shanghai, Shanghai, CHINA
1 shared publication- Qiaozhen Zhang
Shanghai Normal University
1 shared publication Xiangfen Zhang
Shanghai Normal University, Shanghai, Shanghai, CHINA
1 shared publication
Latest Publications
- 26 March 2021
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 30 (5) , 055006
Design and analysis of piezoelectric micromachined ultrasonic transducer using high coupling PMN-PT single crystal thin film for ultrasound imaging
Due to its higher frequency, improved impedance matching, and easy formation of array, piezoelectric micromachined ultrasonic transducer (PMUT) has drawn much attentions for application in ultrasound imaging. In this paper, PMUT based on [011] poled 0.70Pb(Mg 1/3 Nb 2/3 )O 3 –0.30PbTiO 3 (PMN-0.30PT) single crystal thin film was proposed and modeled by performing finite element method. Influences of different configurations of top electrode shape and bottom cavity shape on PMUT performance were studied. The investigation results show that the resonant frequency of PMN-PT-based PMUT with circular top electrode and square bottom cavity is up to 27.155 MHz. The effective electromechanical coupling coefficient ( k eff 2 ) of PMUT was up to 2.32%, which was 127% larger than that of lead zirconate titanate-based PMUT. The static transmitting sensitivity was three times enhancement compared to PMUT with square top electrode and square bottom cavity. Furthermore, acoustic field characteristics of PMUT and PMUT arrays based on PMN-PT in water were investigated. The relative pulse-echo sensitivity level of 2 × 2 PMUT array was −35 dB with the reflector at 200 μ m. The obtained results demonstrated that the proposed PMN-PT-based PMUT can achieve high frequency and large k eff 2 as well as considerable sensitivity, which is promising for application in high resolution ultrasound imaging.
- 26 March 2021
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 30 (5) , 055006
Design and analysis of piezoelectric micromachined ultrasonic transducer using high coupling PMN-PT single crystal thin film for ultrasound imaging
Due to its higher frequency, improved impedance matching, and easy formation of array, piezoelectric micromachined ultrasonic transducer (PMUT) has drawn much attentions for application in ultrasound imaging. In this paper, PMUT based on [011] poled 0.70Pb(Mg 1/3 Nb 2/3 )O 3 –0.30PbTiO 3 (PMN-0.30PT) single crystal thin film was proposed and modeled by performing finite element method. Influences of different configurations of top electrode shape and bottom cavity shape on PMUT performance were studied. The investigation results show that the resonant frequency of PMN-PT-based PMUT with circular top electrode and square bottom cavity is up to 27.155 MHz. The effective electromechanical coupling coefficient ( k eff 2 ) of PMUT was up to 2.32%, which was 127% larger than that of lead zirconate titanate-based PMUT. The static transmitting sensitivity was three times enhancement compared to PMUT with square top electrode and square bottom cavity. Furthermore, acoustic field characteristics of PMUT and PMUT arrays based on PMN-PT in water were investigated. The relative pulse-echo sensitivity level of 2 × 2 PMUT array was −35 dB with the reflector at 200 μ m. The obtained results demonstrated that the proposed PMN-PT-based PMUT can achieve high frequency and large k eff 2 as well as considerable sensitivity, which is promising for application in high resolution ultrasound imaging.