Karl Marvin Tan
Research Subjects
Karl Marvin Tan has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Bhaskar Kumar Somani
University Hospital Southampton NHS Trust, UK
3 shared publications - Daniele Castellani
Department of Medicine and Surgery, Libera Università Mediterranea (LUM) University “Giuseppe Degennaro”, Casamassima, Italy
3 shared publications - Steffi Kar Kei Yuen
The Chinese University of Hong Kong
3 shared publications - Vineet Gauhar
Ng Teng Fong General Hospital, Singapore, Singapore
3 shared publications - Deepak Ragoori
Department of Urology, Asian Institute of Nephrology and Urology, Hyderabad, India
2 shared publications - Khi Yung Fong
Department of Urology, Singapore General Hospital, Singapore, Singapore
2 shared publications
Latest Publications
- Open Access
- 19 January 2026
- Published by Springer Nature in World Journal of Urology
- Vol. 44 (1) , 113
How do we choose the optimal length of flexible and navigable suction ureteral access sheaths (FANS): an EAU endourology and AUSET prospective multicenter analysis
Purpose: To evaluate how to assess the optimal length of flexible and navigable suction ureteral access sheaths (FANS) to be used during flexible ureteroscopy (FURS) for kidney stones. Methods: A prospective multicenter study (16 centers, July 2024–January 2025) enrolled 226 adults with normal renal anatomy undergoing FURS with FANS for renal stones. Three preoperative measurements were analyzed: (1) Subjective on X-ray: T12–pubic symphysis, (2) Objective on CT: upper pole–pubic symphysis, and (3) Dynamic ureteral catheter length with retrograde pyelogram (RPG): upper pole–urethral meatus. Sheath length appropriateness (too short/correct/too long) was assessed intraoperatively using predefined criteria (complete calyceal access, ergonomics, need for ancillary techniques). Secondary outcomes included 30-day stone-free rates (SFR) and complications. Results: Sheath length was deemed correct in 63.7%, too short in 9.7%, and too long in 26.5% of cases. For both genders, dynamic measurement of ureteric catheter length from upper pole calyx to 5 cm beyond the urethral meatus demonstrated the strongest correlation with optimal length ( R = 0.7). Gender-specific formulas for optimal FANS length were derived: Male: 0.52 × ureteral catheter length + 26 cm. Female: 1.2 × ureteral catheter length − 2.1 cm. Compensatory techniques for length discrepancies included assistant-held stabilization of FANS (28.3%) and telescoping of penis (3.5%). 96% of sheaths accessed all calyces. The 30-day SFR was 92.5% (Grade A: 79.2% zero fragments; Grade B: 13.3% fragments ≤ 2 mm). Complications were low: sepsis not requiring ICU admission (0.4%) and ureteric stricture (0.6%). Only 2.7% patients were planned for reintervention. Conclusion: The selection of an optimal FANS length is critical for optimizing outcomes in FURS. Dynamic RPG-ureteral catheter length measurement best predicts this, enabling gender-specific formulas for easy estimation. Our results provide valuable insights into the clinical relevance of preoperative measurements, intraoperative adjustments, and the impact of sheath length on procedural success and complications.
- 19 January 2026
- Published by Springer Nature in World Journal of Urology
- Vol. 44 (1) , 113
Open AccessHow do we choose the optimal length of flexible and navigable suction ureteral access sheaths (FANS): an EAU endourology and AUSET prospective multicenter analysis
Purpose: To evaluate how to assess the optimal length of flexible and navigable suction ureteral access sheaths (FANS) to be used during flexible ureteroscopy (FURS) for kidney stones. Methods: A prospective multicenter study (16 centers, July 2024–January 2025) enrolled 226 adults with normal renal anatomy undergoing FURS with FANS for renal stones. Three preoperative measurements were analyzed: (1) Subjective on X-ray: T12–pubic symphysis, (2) Objective on CT: upper pole–pubic symphysis, and (3) Dynamic ureteral catheter length with retrograde pyelogram (RPG): upper pole–urethral meatus. Sheath length appropriateness (too short/correct/too long) was assessed intraoperatively using predefined criteria (complete calyceal access, ergonomics, need for ancillary techniques). Secondary outcomes included 30-day stone-free rates (SFR) and complications. Results: Sheath length was deemed correct in 63.7%, too short in 9.7%, and too long in 26.5% of cases. For both genders, dynamic measurement of ureteric catheter length from upper pole calyx to 5 cm beyond the urethral meatus demonstrated the strongest correlation with optimal length ( R = 0.7). Gender-specific formulas for optimal FANS length were derived: Male: 0.52 × ureteral catheter length + 26 cm. Female: 1.2 × ureteral catheter length − 2.1 cm. Compensatory techniques for length discrepancies included assistant-held stabilization of FANS (28.3%) and telescoping of penis (3.5%). 96% of sheaths accessed all calyces. The 30-day SFR was 92.5% (Grade A: 79.2% zero fragments; Grade B: 13.3% fragments ≤ 2 mm). Complications were low: sepsis not requiring ICU admission (0.4%) and ureteric stricture (0.6%). Only 2.7% patients were planned for reintervention. Conclusion: The selection of an optimal FANS length is critical for optimizing outcomes in FURS. Dynamic RPG-ureteral catheter length measurement best predicts this, enabling gender-specific formulas for easy estimation. Our results provide valuable insights into the clinical relevance of preoperative measurements, intraoperative adjustments, and the impact of sheath length on procedural success and complications.
- Open Access
- 1 January 2025
- Published by XMLink in Investigative and Clinical Urology
- Vol. 66 (3) , 236-244
Can flexible ureteroscopy using flexible and navigable suction ureteral access sheath (FANS-UAS) minimize postoperative double J stent placement? Results from a propensity score-matched analysis of 540 patients of the European Association of Urology Section of Endourology and global FANS collaborative study group
Castellani D, et al. Investig Clin Urol. 2025 Apr;66:e25. https://doi.org/10.4111/icu.20250071
- 1 January 2025
- Published by XMLink in Investigative and Clinical Urology
- Vol. 66 (3) , 236-244
Open AccessCan flexible ureteroscopy using flexible and navigable suction ureteral access sheath (FANS-UAS) minimize postoperative double J stent placement? Results from a propensity score-matched analysis of 540 patients of the European Association of Urology Section of Endourology and global FANS collaborative study group
Castellani D, et al. Investig Clin Urol. 2025 Apr;66:e25. https://doi.org/10.4111/icu.20250071
- 20 December 2024
- Published by Springer Nature in World Journal of Urology
- Vol. 43 (1) , 1-7
Assessing flexible ureteroscopy outcomes for lower Pole versus non lower Pole stones using the flexible and navigable suction ureteric access sheath: a prospective multicenter study by EAU Endourology and PEARLS group
Purpose Use of suction in flexible ureteroscopy is increasing lately. The introduction of flexible and navigable suction access sheath (FANS) has shown improved stone free rate (SFR). However, its efficacy in lower pole stone (LPS) in terms of SFR and complications is yet to be studied. Methods We collected data from 25 centers that included 394 adult patients undergoing ureteroscopy using FANS. Non contrast CT (NCCT) scan was done within first 30 days post operatively to access the SFR. Residual fragments were graded as A: 100% SFR; B: single fragment ≤ 2 mm; C: single fragment 2.1–4 mm; D: Single or multiple fragments > 4 mm. Post operative complications were recorded. Results Out of 394 patients, non LPS (group1) comprised of 268 patients, rest 126 patients had LPS (group 2). Single stage zero fragment SFR was seen in 58.6% (group 1) vs. 54.8% (group 2) (P = 0.619). Single stage grade A + B SFR was achieved in 96.6% vs. 98.4% in groups 1 and 2 respectively. On multivariate analysis Thulium fiber laser use was significantly associated with higher odds of being grade A stone-free, while stone volume with lower odds. In LPS group only two patients needed reintervention. The highest grade of complication was Clavien 2, which was seen in 3.2% LPS group. Conclusion Use of flexible and navigable suction ureteric access sheath for lower pole stones is effective and safe. The stone free rate of lower pole stones is comparable to non-lower pole locations with very low reintervention rate in both groups.
- 20 December 2024
- Published by Springer Nature in World Journal of Urology
- Vol. 43 (1) , 1-7
Assessing flexible ureteroscopy outcomes for lower Pole versus non lower Pole stones using the flexible and navigable suction ureteric access sheath: a prospective multicenter study by EAU Endourology and PEARLS group
Purpose Use of suction in flexible ureteroscopy is increasing lately. The introduction of flexible and navigable suction access sheath (FANS) has shown improved stone free rate (SFR). However, its efficacy in lower pole stone (LPS) in terms of SFR and complications is yet to be studied. Methods We collected data from 25 centers that included 394 adult patients undergoing ureteroscopy using FANS. Non contrast CT (NCCT) scan was done within first 30 days post operatively to access the SFR. Residual fragments were graded as A: 100% SFR; B: single fragment ≤ 2 mm; C: single fragment 2.1–4 mm; D: Single or multiple fragments > 4 mm. Post operative complications were recorded. Results Out of 394 patients, non LPS (group1) comprised of 268 patients, rest 126 patients had LPS (group 2). Single stage zero fragment SFR was seen in 58.6% (group 1) vs. 54.8% (group 2) (P = 0.619). Single stage grade A + B SFR was achieved in 96.6% vs. 98.4% in groups 1 and 2 respectively. On multivariate analysis Thulium fiber laser use was significantly associated with higher odds of being grade A stone-free, while stone volume with lower odds. In LPS group only two patients needed reintervention. The highest grade of complication was Clavien 2, which was seen in 3.2% LPS group. Conclusion Use of flexible and navigable suction ureteric access sheath for lower pole stones is effective and safe. The stone free rate of lower pole stones is comparable to non-lower pole locations with very low reintervention rate in both groups.