JTJihong Tang

Jihong Tang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jihong Tang has a total of 18 co-authors. Here are the top co-authors by number of shared publications:

  • Yakang Dai

    Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, China

    2 shared publications
  • Bingbing Zhang

    Children's Hospital of Soochow University Jiangsu Province China

    1 shared publication
  • Bo You

    Heilongjiang Provincial Key Laboratory of Complex Intelligent System and Integration, Harbin University of Science and Technology, Harbin 150080, China

    1 shared publication
  • Guihai Suo

    Department of Neurology, Childrens Hospital of Soochow University, Suzhou, China

    1 shared publication
  • Jihong Tang

    Children’s Hospital of Soochow University, Suzhou, 215000 China

    1 shared publication
  • Jing Huang

    Department of Neurology, Childrens Hospital of Soochow University, Suzhou, China

    1 shared publication

Latest Publications

  • Open Access

    De Novo Variant in GBX1 Gene Associated With Developmental Delay and Focal Epilepsy

    by Bingbing Zhang, Xiaohua Li, Xiao Qian, Jihong Tang

    Background: The gastrulation brain homeobox (Gbx) family, including GBX1 and GBX2, is crucial for hindbrain development and contributes to the morphogenesis of the midbrain–hindbrain boundary (MHB). While the role of the GBX1 gene in the development of the human nervous system remains to be elucidated, its variant in humans has not previously been reported to be associated with disease.Methods: The patient presenting with sleep panic attacks underwent comprehensive clinical assessments, including electroencephalograph (EEG), magnetic resonance imaging (MRI), and genetic testing through whole exome sequencing (WES). Zebrafish models were generated through gbx1 gene crispants to investigate the functional impact of identified genetic variants.Results: The patient in our study was diagnosed with focal epilepsy through long‐range EEG. WES revealed a de novo GBX1 gene variant [NM_001098834.3: c.910C>T (p.Gln304*)]. In zebrafish larvae with gbx1 gene disruption, significant abnormalities were observed in the morphology of the interocular area. Furthermore, these larvae exhibited an increased susceptibility to neurophysiological abnormalities associated with epileptiform activity.Conclusion: Our study is the first to identify an association between the GBX1 gene variant and focal epilepsy. The zebrafish models confirmed the presence of related phenotypes in the gbx1‐Cas9. These findings underscore the significance of the GBX1 gene in neurological function.


  • Whole-Brain Dynamic Resting-State Functional Network Analysis in Benign Epilepsy With Centrotemporal Spikes

    by Siqi Zhang, Jihong Tang, Jing Huang, Guihai Suo, Zhiyong Zhou, Bo You, Yakang Dai, Yan Liu

    Benign epilepsy with centrotemporal spikes (BECTS), the most common type of epilepsy among children, is considered a network disorder. Both fMRI and EEG source imaging (ESI) studies have indicated that BECTS is associated with static resting-state functional network (SFN) alterations (e.g., decreased global efficiency) in source space. However, we find that the abovementioned alterations are not significant when the SFN calculations are performed in the scalp space using only clinical routine low-density (e.g., 19 channels) EEG recordings (shown in our results). In the context of EEG microstates, it is clear that networks in the scalp space with resting-state EEG recordings dynamically reconfigure in a well-organized way based on different functional states. We are therefore inspired to propose a whole-brain dynamic resting-state functional network (DFN) computation method based on resting-state low-density EEG recordings with four classical microstates in scalp space. Notably, on the one hand, this approach is suitable for clinical conditions, and, on the other hand, the dynamic alternations calculated with a DFN may promote our understanding of how the networks change in BECTS. We analysed the changes in a DFN in six frequency bands (δ, θ, α low , α high , β, and γ) in patients with BECTS compared to those for healthy controls. Superior to traditional SFNs, the proposed DFN can reveal significant differences between individuals with BECTS and healthy controls (e.g., lower global efficiency), thus matching traditional fMRI and ESI methods in the source space. Our method directly performs DFN computations from low-density EEG recordings and avoids complex ESI computations, making it promising for clinical applications, especially in the outpatient diagnosis stage.


  • Open Access

    An Efficient and Robust Muscle Artifact Removal Method for Few-Channel EEG

    by Yan Liu, Yakang Dai, Yuanfeng Zhou, Xun Lang, Yipeng Liu, Qian Zheng, Yanjiong Zhang, Xu Jiang, Li Zhang, Jihong Tang

    The unavoidable muscle artifacts pose challenges on reliable interpretation of the electroencephalogram (EEG) recordings, especially for the wearable few-channel EEG, a new emerging scenario. However, the high computational load and low robustness of the existing methods limit its wider applications and performance in artifact removal. Consequently, we propose an efficient and robust muscle artifact removal approach by jointly employing the Fast Multivariate Empirical Mode Decomposition (FMEMD) and CCA for few-channel EEG. The proposed FMEMD-CCA firstly efficiently decomposes the input EEG recordings into several multivariate Intrinsic Mode Functions (IMF) by applying FMEMD. Secondly, all the multivariate IMFs are processed by CCA for computing the underlying sources. Finally, the sources with low autocorrelations are smartly determined as muscle artifacts and rejected, and therefore the other components are reconstructed for EMG-artifact-free IMFs and EEG. Simulated and real data experiments are carried out for verifying the performance of the proposed method. It takes 10 times less computing time in FMEMD-CCA compared with in Multivariate Empirical Mode Decomposition (MEMD)-CCA for 10-s EEG recordings, using the same computer and software. And the accuracy and the average correlation coefficient are highly consistent in both approaches. Furthermore, in contrast to MEMD-CCA, the proposed FMEMD-CCA works more robustly in low sampling rate based on the real data and benchmark.