Alan Blakeman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Alan Blakeman has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Karen Ann Gordon
Institute of Medical Science, The University of Toronto, Toronto, Canada.
3 shared publications - Robel Z. Alemu
The Hospital for Sick Children
3 shared publications - Angela Lim Fung
The Hospital for Sick Children
2 shared publications Blake C. Papsin
The Hospital for Sick Children
2 shared publications- Jaina Negandhi
The Hospital for Sick Children
2 shared publications - Sharon Lynn Cushing
Hospital for Sick Children, Department of Otolaryngology-Head & Neck Surgery, University of Toronto, Toronto, Ontario, Canada
2 shared publications
Latest Publications
- Open Access
- 1 January 2026
- Published by SAGE Publications in Trends in Hearing
- Vol. 30
Benefits of Bilateral Bone Conduction Device Use Including Osia Devices in Children and Adolescents With Bilateral Atresia
This study aimed to characterize effects of bilateral bone conduction devices (BCD) including the Cochlear™ Osia ® (Osia) and the Cochlear™ percutaneous Baha ® Connect System (Baha) on localization of stationary and moving sound in children and adolescents with bilateral atresia. Participants were 11 listeners with BCDs [ M Age (SD) = 14.7(3.5) years] and 11 age-matched controls [ M Age (SD) = 14.9(1.9) years]. Outcomes were word recognition in quiet and noise, spatial release from masking (SRM) [spondee-word recognition thresholds in noise at co-located/0° or separated (90° left/right) positions], self-reported hearing using the Speech, Spatial and Qualities of Hearing Scale (SSQ), and localization of stationary and moving sound with tracking of real-time unrestricted head movements. BCD users had reduced speech perception accuracy in noise during unilateral listening ( p < .001) and higher speech recognition thresholds than controls ( p = .001). BCD users had higher errors than controls during stationary ( p < .001) and moving ( p < .001) sound localization consistent with self-reported spatial hearing challenges. BCD users had significantly reduced errors during bilateral use compared to unilateral use for stationary ( p < .01) but not always for moving (right unilateral: p < .01; left unilateral: p = .46) sound localization. BCD users spent less time moving their heads in the correct direction compared to controls for stationary and moving sound localization ( p < .01). Results indicate that children and adolescents with BCDs demonstrate improved localization of stationary but not moving sound-sources, with bilateral device use compared to unilateral use. This finding provides evidence for some access to binaural cues and mitigation of head shadow despite transcranial attenuation, but ineffective use of head movements.
- 1 January 2026
- Published by SAGE Publications in Trends in Hearing
- Vol. 30
Open AccessBenefits of Bilateral Bone Conduction Device Use Including Osia Devices in Children and Adolescents With Bilateral Atresia
This study aimed to characterize effects of bilateral bone conduction devices (BCD) including the Cochlear™ Osia ® (Osia) and the Cochlear™ percutaneous Baha ® Connect System (Baha) on localization of stationary and moving sound in children and adolescents with bilateral atresia. Participants were 11 listeners with BCDs [ M Age (SD) = 14.7(3.5) years] and 11 age-matched controls [ M Age (SD) = 14.9(1.9) years]. Outcomes were word recognition in quiet and noise, spatial release from masking (SRM) [spondee-word recognition thresholds in noise at co-located/0° or separated (90° left/right) positions], self-reported hearing using the Speech, Spatial and Qualities of Hearing Scale (SSQ), and localization of stationary and moving sound with tracking of real-time unrestricted head movements. BCD users had reduced speech perception accuracy in noise during unilateral listening ( p < .001) and higher speech recognition thresholds than controls ( p = .001). BCD users had higher errors than controls during stationary ( p < .001) and moving ( p < .001) sound localization consistent with self-reported spatial hearing challenges. BCD users had significantly reduced errors during bilateral use compared to unilateral use for stationary ( p < .01) but not always for moving (right unilateral: p < .01; left unilateral: p = .46) sound localization. BCD users spent less time moving their heads in the correct direction compared to controls for stationary and moving sound localization ( p < .01). Results indicate that children and adolescents with BCDs demonstrate improved localization of stationary but not moving sound-sources, with bilateral device use compared to unilateral use. This finding provides evidence for some access to binaural cues and mitigation of head shadow despite transcranial attenuation, but ineffective use of head movements.
- Open Access
- 4 July 2025
- Published by SAGE Publications in Trends in Hearing
- Vol. 29
Children With Bilateral Cochlear Implants Show Emerging Spatial Hearing of Stationary and Moving Sound
Spatial hearing in children with bilateral cochlear implants (BCIs) was assessed by: (a) comparing localization of stationary and moving sound, (b) investigating the relationship between sound localization and sensitivity to interaural level and timing differences (ILDs/ITDs), (c) evaluating effects of aural preference on sound localization, and (d) exploring head and eye (gaze) movements during sound localization. Children with BCIs ( n = 42, M Age = 12.3 years) with limited duration of auditory deprivation and peers with typical hearing (controls; n = 37, M Age = 12.9 years) localized stationary and moving sound with unrestricted head and eye movements. Sensitivity to binaural cues was measured by a lateralization task to ILDs and ITDs. Spatial separation effects were measured by spondee-word recognition thresholds (SNR thresholds) when noise was presented in front (colocated/0°) or with 90° of left/right separation. BCI users had good speech reception thresholds (SRTs) in quiet but higher SRTs in noise than controls. Spatial separation of noise from speech revealed a greater advantage for the right ear across groups. BCI users showed increased errors localizing stationary sound and detecting moving sound direction compared to controls. Decreased ITD sensitivity occurred with poorer localization of stationary sound in BCI users. Gaze movements in BCI users were more random than controls for stationary and moving sounds. BCIs support symmetric hearing in children with limited duration of auditory deprivation and promote spatial hearing which is albeit impaired. Spatial hearing was thus considered to be “emerging.” Remaining challenges may reflect disruptions in ITD sensitivity and ineffective gaze movements.
- 4 July 2025
- Published by SAGE Publications in Trends in Hearing
- Vol. 29
Open AccessChildren With Bilateral Cochlear Implants Show Emerging Spatial Hearing of Stationary and Moving Sound
Spatial hearing in children with bilateral cochlear implants (BCIs) was assessed by: (a) comparing localization of stationary and moving sound, (b) investigating the relationship between sound localization and sensitivity to interaural level and timing differences (ILDs/ITDs), (c) evaluating effects of aural preference on sound localization, and (d) exploring head and eye (gaze) movements during sound localization. Children with BCIs ( n = 42, M Age = 12.3 years) with limited duration of auditory deprivation and peers with typical hearing (controls; n = 37, M Age = 12.9 years) localized stationary and moving sound with unrestricted head and eye movements. Sensitivity to binaural cues was measured by a lateralization task to ILDs and ITDs. Spatial separation effects were measured by spondee-word recognition thresholds (SNR thresholds) when noise was presented in front (colocated/0°) or with 90° of left/right separation. BCI users had good speech reception thresholds (SRTs) in quiet but higher SRTs in noise than controls. Spatial separation of noise from speech revealed a greater advantage for the right ear across groups. BCI users showed increased errors localizing stationary sound and detecting moving sound direction compared to controls. Decreased ITD sensitivity occurred with poorer localization of stationary sound in BCI users. Gaze movements in BCI users were more random than controls for stationary and moving sounds. BCIs support symmetric hearing in children with limited duration of auditory deprivation and promote spatial hearing which is albeit impaired. Spatial hearing was thus considered to be “emerging.” Remaining challenges may reflect disruptions in ITD sensitivity and ineffective gaze movements.
- 10 March 2025
- Published by Elsevier in Clinical Neurophysiology
- Vol. 173, 52-63
Clinical programming can limit access to binaural cues in children with bilateral cochlear implants
- 10 March 2025
- Published by Elsevier in Clinical Neurophysiology
- Vol. 173, 52-63
Clinical programming can limit access to binaural cues in children with bilateral cochlear implants