Spencer F. Smith
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Spencer F. Smith has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Billy Randall Hammond
Vision Sciences Laboratory, Behavioral and Brain Sciences Program, University of Georgia, Athens, GA, USA
3 shared publications - Jacob B. Harth
Institute of Gerontology, College of Public Health, University of Georgia, Athens, GA 30602, USA
2 shared publications - Lisa M. Renzi-Hammond
University of Georgia
2 shared publications - Cameron J. Wysocky
Vision Sciences Laboratory, Behavioral and Brain Sciences Program, Department of Psychology, University of Georgia, 125 Baldwin Street, Athens, GA 30602, USA
1 shared publication Jacob B Harth
Institute of Gerontology; College of Public Health; University of Georgia, Athens, GA
1 shared publicationLisa M Renzi-Hammond
Institute of Gerontology; College of Public Health; University of Georgia, Athens, GA
1 shared publication
Latest Publications
- Open Access
- 10 March 2026
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 264 (7) , 2041-2046
Seeing through the veil: blue-light filtering and peak contrast sensitivity in pseudophakic patients
Purpose Atmospheric short-wave scattered light (blue haze) limits visual range by reducing the contrast of distant objects. While theoretical models and prior research suggest that filtering short wavelengths can improve visual range, significant individual differences persist in tolerance to veiling luminance, even among individuals with similar ocular health and acuity. This study examined whether a commercially available blue-light filtering (BLF) lens design could enhance visual range under simulated blue haze conditions in an older pseudophakic population. Methods Forty older pseudophakic adults (M = 71.15 ± 5.82 years) were tested using a randomized, controlled, cross-over design. Visual range was assessed via a custom two-channel optical system presenting a sinusoidal grating target veiled by adjustable blue haze (Correlated Color Temperature = 9424 K). Participants viewed the target through a clear control lens and a test BLF lens in randomized order. Visual range thresholds, defined as the maximum blue haze energy tolerated before target detection failed, were determined using the psychophysical method of limits. Results Participants tolerated significantly greater (U = 1035.00; p = 0.024) average blue haze energy with the BLF lens (3.49 log relative energy [LRE]) than with the clear control lens (3.43 LRE). On average, the BLF lens allowed participants to withstand approximately 19% more veiling luminance before target obscuration. Conclusions Consistent with theoretical predictions and prior findings in younger adults, BLF lens designs significantly enhanced visual range in older pseudophakic participants under simulated blue haze conditions. These findings suggest that BLF lenses may offer functional visual benefits in older adults, especially in populations with intraocular lens implants lacking native blue-light filtration. Future research should extend these results using field studies in outdoor environments.
- 10 March 2026
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 264 (7) , 2041-2046
Open AccessSeeing through the veil: blue-light filtering and peak contrast sensitivity in pseudophakic patients
Purpose Atmospheric short-wave scattered light (blue haze) limits visual range by reducing the contrast of distant objects. While theoretical models and prior research suggest that filtering short wavelengths can improve visual range, significant individual differences persist in tolerance to veiling luminance, even among individuals with similar ocular health and acuity. This study examined whether a commercially available blue-light filtering (BLF) lens design could enhance visual range under simulated blue haze conditions in an older pseudophakic population. Methods Forty older pseudophakic adults (M = 71.15 ± 5.82 years) were tested using a randomized, controlled, cross-over design. Visual range was assessed via a custom two-channel optical system presenting a sinusoidal grating target veiled by adjustable blue haze (Correlated Color Temperature = 9424 K). Participants viewed the target through a clear control lens and a test BLF lens in randomized order. Visual range thresholds, defined as the maximum blue haze energy tolerated before target detection failed, were determined using the psychophysical method of limits. Results Participants tolerated significantly greater (U = 1035.00; p = 0.024) average blue haze energy with the BLF lens (3.49 log relative energy [LRE]) than with the clear control lens (3.43 LRE). On average, the BLF lens allowed participants to withstand approximately 19% more veiling luminance before target obscuration. Conclusions Consistent with theoretical predictions and prior findings in younger adults, BLF lens designs significantly enhanced visual range in older pseudophakic participants under simulated blue haze conditions. These findings suggest that BLF lenses may offer functional visual benefits in older adults, especially in populations with intraocular lens implants lacking native blue-light filtration. Future research should extend these results using field studies in outdoor environments.
- Open Access
- 23 April 2025
- Published by MDPI AG in Inventions
- Vol. 10 (3) , 33
A Novel Characterization of the Lower Threshold of Motion
Methodologies to measure motion perception are vital for deepening our understanding of the vision system and the factors that influence it. While existing work has primarily focused on the fastest perceivable velocities, less attention has been paid to the lower threshold of motion (LTM; slowest perceivable velocities). In this study, we designed an optical system to measure LTM in a sample of healthy young adults and to assess the influence of retinal location (central vs. peripheral retina) and stimulus composition (broadband vs. mid-wave) on LTM. The system was based on a xenon light source and a fiber-optic cable that created a bright light stimulus that could be moved along a computer-controlled precision translation slide. The stimulus, exposed for one-second intervals at both a central (fovea) and a peripheral (33 deg) location, was moved at varying speeds to determine the slowest detectable speed. In all, 37 healthy young participants (M = 19.32 ± 1.97 years) were tested. We found substantial between-subject variability in LTM and an interaction between stimulus wavelength and retinal location. The measurement of LTM using this novel apparatus and methodology provides insights into the relationship between slow-moving, ecologically valid stimuli and perceptual detection at the slowest speeds.
- 23 April 2025
- Published by MDPI AG in Inventions
- Vol. 10 (3) , 33
Open AccessA Novel Characterization of the Lower Threshold of Motion
Methodologies to measure motion perception are vital for deepening our understanding of the vision system and the factors that influence it. While existing work has primarily focused on the fastest perceivable velocities, less attention has been paid to the lower threshold of motion (LTM; slowest perceivable velocities). In this study, we designed an optical system to measure LTM in a sample of healthy young adults and to assess the influence of retinal location (central vs. peripheral retina) and stimulus composition (broadband vs. mid-wave) on LTM. The system was based on a xenon light source and a fiber-optic cable that created a bright light stimulus that could be moved along a computer-controlled precision translation slide. The stimulus, exposed for one-second intervals at both a central (fovea) and a peripheral (33 deg) location, was moved at varying speeds to determine the slowest detectable speed. In all, 37 healthy young participants (M = 19.32 ± 1.97 years) were tested. We found substantial between-subject variability in LTM and an interaction between stimulus wavelength and retinal location. The measurement of LTM using this novel apparatus and methodology provides insights into the relationship between slow-moving, ecologically valid stimuli and perceptual detection at the slowest speeds.
- 13 March 2025
- Published by Elsevier in The Journal of Nutrition
- Vol. 155 (5) , 1324-1330
The Relation Between Carotenoids Measured in the Skin and Eye
- 13 March 2025
- Published by Elsevier in The Journal of Nutrition
- Vol. 155 (5) , 1324-1330
The Relation Between Carotenoids Measured in the Skin and Eye