Johanna Günther
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Johanna Günther has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Philipp Gruschwitz
Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Würzburg, Germany
3 shared publications Dominik Peter
Department of General, Visceral, Transplant, Vascular and Pediatric Surgery, Center of Operative Medicine, University Hospital Würzburg, Würzburg, Germany
2 shared publicationsFlorian Kleefeldt
Institute of Anatomy and Cell Biology, University of Würzburg, Würzburg, Germany
2 shared publications- Martin Andreas Rückert
Julius-Maximilians University, Germany
2 shared publications - Patrick Vogel
Department of Experimental Physics 5 (Biophysics), Julius-Maximilians-University Würzburg, Würzburg, Germany
2 shared publications - Teresa Reichl
Julius-Maximilians University, Germany
2 shared publications
Latest Publications
- Open Access
- 7 May 2026
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
First In-vivo Human Magnetic Particle Imaging
Magnetic particle imaging (MPI) is a tracer-based imaging modality enabling radiation-free visualization of superparamagnetic iron oxide nanoparticles with high temporal resolution. Despite extensive preclinical development, in-vivo application in humans has not previously been reported so far. This study aimed to demonstrate the feasibility of first-in-human MPI angiography and to compare it with conventional X-ray digital subtraction angiography (DSA). A first-in-human MPI angiography was performed in a healthy volunteer using a human-scale interventional MPI scanner and clinically approved ferucarbotran tracer. Imaging of the upper extremity veins was conducted under clinical angiography laboratory conditions with continuous physiological monitoring. Conventional DSA of the same region was performed under identical procedural conditions for direct comparison. MPI data were acquired in real time with 2 frames per second and co-registered with DSA images. MPI successfully visualized major superficial and deep veins, including inflow, branching patterns, venous valve filling, collateral pathways, and tracer clearance dynamics. Spatial and temporal visualization was comparable to DSA for clinically relevant vascular structures. No adverse events occurred, and safety monitoring remained unremarkable throughout the procedure. This first in-vivo human demonstration shows that MPI enables real-time, radiation-free angiographic visualization of vascular structures with clinically relevant temporal resolution. MPI has potential as a novel imaging modality for selected vascular and interventional applications and represents an important step toward clinical translation.
- 7 May 2026
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
Open AccessFirst In-vivo Human Magnetic Particle Imaging
Magnetic particle imaging (MPI) is a tracer-based imaging modality enabling radiation-free visualization of superparamagnetic iron oxide nanoparticles with high temporal resolution. Despite extensive preclinical development, in-vivo application in humans has not previously been reported so far. This study aimed to demonstrate the feasibility of first-in-human MPI angiography and to compare it with conventional X-ray digital subtraction angiography (DSA). A first-in-human MPI angiography was performed in a healthy volunteer using a human-scale interventional MPI scanner and clinically approved ferucarbotran tracer. Imaging of the upper extremity veins was conducted under clinical angiography laboratory conditions with continuous physiological monitoring. Conventional DSA of the same region was performed under identical procedural conditions for direct comparison. MPI data were acquired in real time with 2 frames per second and co-registered with DSA images. MPI successfully visualized major superficial and deep veins, including inflow, branching patterns, venous valve filling, collateral pathways, and tracer clearance dynamics. Spatial and temporal visualization was comparable to DSA for clinically relevant vascular structures. No adverse events occurred, and safety monitoring remained unremarkable throughout the procedure. This first in-vivo human demonstration shows that MPI enables real-time, radiation-free angiographic visualization of vascular structures with clinically relevant temporal resolution. MPI has potential as a novel imaging modality for selected vascular and interventional applications and represents an important step toward clinical translation.
- Open Access
- 1 December 2025
- Published by Springer Nature in Communications Engineering
- Vol. 4 (1)
Towards clinical magnetic particle imaging: safety measurements of medical implants in a human cadaver model
Magnetic Particle Imaging (MPI) is a preclinical imaging modality with potential for future clinical usage. The radiation-free guidance of endovascular interventions with MPI is especially promising. Here, we present a safety study on the heating of metallic medical implants during MPI measurements under realistic conditions in an extracorporeally-perfused cadaver model. The measurements were conducted by fiberoptic thermometers and showed no detectable heating of the tested endovascular devices in the cadaver model. A temperature increase of no more than 0.11 K was observed on the surface of the investigated proximal femoral nail. The in vitro testing of orthopedic prostheses (knee and hip) revealed a slight heating effect of 0.45 K. The dependence of heating on the applied excitation frequency was measured. Overall, the tested repertoire of implants did not heat by a clinically-relevant amount in a human-sized MPI-scanner under realistic conditions, indicating their safe usage in future clinical applications.
- 1 December 2025
- Published by Springer Nature in Communications Engineering
- Vol. 4 (1)
Open AccessTowards clinical magnetic particle imaging: safety measurements of medical implants in a human cadaver model
Magnetic Particle Imaging (MPI) is a preclinical imaging modality with potential for future clinical usage. The radiation-free guidance of endovascular interventions with MPI is especially promising. Here, we present a safety study on the heating of metallic medical implants during MPI measurements under realistic conditions in an extracorporeally-perfused cadaver model. The measurements were conducted by fiberoptic thermometers and showed no detectable heating of the tested endovascular devices in the cadaver model. A temperature increase of no more than 0.11 K was observed on the surface of the investigated proximal femoral nail. The in vitro testing of orthopedic prostheses (knee and hip) revealed a slight heating effect of 0.45 K. The dependence of heating on the applied excitation frequency was measured. Overall, the tested repertoire of implants did not heat by a clinically-relevant amount in a human-sized MPI-scanner under realistic conditions, indicating their safe usage in future clinical applications.
- Open Access
- 13 March 2025
- Published by Springer Nature in Communications Medicine
- Vol. 5 (1) , 1-10
Magnetic particle imaging angiography of the femoral artery in a human cadaveric perfusion model
Background: Magnetic particle imaging (MPI) allows for radiation-free visualization of tracers without background signal. With the first human-sized interventional MPI scanner being recently developed, the aim of the present study was to test its performance for guiding of endovascular procedures in a realistic perfusion model. Methods: Three fresh-frozen cadaveric legs were prepared to establish continuous circulation in the superficial femoral artery via introducer sheaths in the inguinal and infragenicular region. To facilitate vessel visualization, a mixture of a MPI tracer (Resotran® or Perimag®) and X-ray contrast agent was injected under continuous extracorporeal perfusion and imaged simultaneously with MPI angiography and digital subtraction angiography (DSA) as reference. Results: The MPI scanner integrates seamlessly into the standard operating procedures in the angiography suite and simultaneous imaging with DSA and MPI is feasible. The MPI scanner detects a tracer bolus of 2 ml Perimag® or 1.5 ml Resotran®. Imaging results are consistent and reproducible in three cadaveric leg phantoms. Conclusion: This study demonstrates, that the recently developed human-sized MPI scanner facilitates reliable radiation-free image guidance for peripheral vascular interventions in the superficial femoral artery with a tracer approved for use in humans.
- 13 March 2025
- Published by Springer Nature in Communications Medicine
- Vol. 5 (1) , 1-10
Open AccessMagnetic particle imaging angiography of the femoral artery in a human cadaveric perfusion model
Background: Magnetic particle imaging (MPI) allows for radiation-free visualization of tracers without background signal. With the first human-sized interventional MPI scanner being recently developed, the aim of the present study was to test its performance for guiding of endovascular procedures in a realistic perfusion model. Methods: Three fresh-frozen cadaveric legs were prepared to establish continuous circulation in the superficial femoral artery via introducer sheaths in the inguinal and infragenicular region. To facilitate vessel visualization, a mixture of a MPI tracer (Resotran® or Perimag®) and X-ray contrast agent was injected under continuous extracorporeal perfusion and imaged simultaneously with MPI angiography and digital subtraction angiography (DSA) as reference. Results: The MPI scanner integrates seamlessly into the standard operating procedures in the angiography suite and simultaneous imaging with DSA and MPI is feasible. The MPI scanner detects a tracer bolus of 2 ml Perimag® or 1.5 ml Resotran®. Imaging results are consistent and reproducible in three cadaveric leg phantoms. Conclusion: This study demonstrates, that the recently developed human-sized MPI scanner facilitates reliable radiation-free image guidance for peripheral vascular interventions in the superficial femoral artery with a tracer approved for use in humans.