JGJohanna Günther

Johanna Günther

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Johanna Günther has a total of 28 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    First In-vivo Human Magnetic Particle Imaging

    by Patrick Vogel, Thomas Kampf, Martin Andreas Rückert, Johanna Günther, Teresa Reichl, Thorsten Bley, Volker C. Behr, Philipp Gruschwitz, Viktor Hartung

    Magnetic particle imaging (MPI) is a tracer-based imaging modality enabling radiation-free visualization of superparamagnetic iron oxide nanoparticles with high temporal resolution. Despite extensive preclinical development, in-vivo application in humans has not previously been reported so far. This study aimed to demonstrate the feasibility of first-in-human MPI angiography and to compare it with conventional X-ray digital subtraction angiography (DSA). A first-in-human MPI angiography was performed in a healthy volunteer using a human-scale interventional MPI scanner and clinically approved ferucarbotran tracer. Imaging of the upper extremity veins was conducted under clinical angiography laboratory conditions with continuous physiological monitoring. Conventional DSA of the same region was performed under identical procedural conditions for direct comparison. MPI data were acquired in real time with 2 frames per second and co-registered with DSA images. MPI successfully visualized major superficial and deep veins, including inflow, branching patterns, venous valve filling, collateral pathways, and tracer clearance dynamics. Spatial and temporal visualization was comparable to DSA for clinically relevant vascular structures. No adverse events occurred, and safety monitoring remained unremarkable throughout the procedure. This first in-vivo human demonstration shows that MPI enables real-time, radiation-free angiographic visualization of vascular structures with clinically relevant temporal resolution. MPI has potential as a novel imaging modality for selected vascular and interventional applications and represents an important step toward clinical translation.


  • Open Access

    Towards clinical magnetic particle imaging: safety measurements of medical implants in a human cadaver model

    by Franz Wegner, Thomas Friedrich, Patrick Naoki Elfers, Florian Kleefeldt, Dominik Peter, Philipp Gruschwitz, Teresa Reichl, Johanna Günther, Thomas Kampf, Martin A. Rückert, et al.

    Magnetic Particle Imaging (MPI) is a preclinical imaging modality with potential for future clinical usage. The radiation-free guidance of endovascular interventions with MPI is especially promising. Here, we present a safety study on the heating of metallic medical implants during MPI measurements under realistic conditions in an extracorporeally-perfused cadaver model. The measurements were conducted by fiberoptic thermometers and showed no detectable heating of the tested endovascular devices in the cadaver model. A temperature increase of no more than 0.11 K was observed on the surface of the investigated proximal femoral nail. The in vitro testing of orthopedic prostheses (knee and hip) revealed a slight heating effect of 0.45 K. The dependence of heating on the applied excitation frequency was measured. Overall, the tested repertoire of implants did not heat by a clinically-relevant amount in a human-sized MPI-scanner under realistic conditions, indicating their safe usage in future clinical applications.


  • Open Access

    Magnetic particle imaging angiography of the femoral artery in a human cadaveric perfusion model

    by Viktor Hartung, Philipp Gruschwitz, Anne Marie Augustin, Jan-Peter Grunz, Florian Kleefeldt, Dominik Peter, Süleyman Ergün, Johanna Günther, Teresa Reichl, Thomas Kampf, et al.

    Background: Magnetic particle imaging (MPI) allows for radiation-free visualization of tracers without background signal. With the first human-sized interventional MPI scanner being recently developed, the aim of the present study was to test its performance for guiding of endovascular procedures in a realistic perfusion model. Methods: Three fresh-frozen cadaveric legs were prepared to establish continuous circulation in the superficial femoral artery via introducer sheaths in the inguinal and infragenicular region. To facilitate vessel visualization, a mixture of a MPI tracer (Resotran® or Perimag®) and X-ray contrast agent was injected under continuous extracorporeal perfusion and imaged simultaneously with MPI angiography and digital subtraction angiography (DSA) as reference. Results: The MPI scanner integrates seamlessly into the standard operating procedures in the angiography suite and simultaneous imaging with DSA and MPI is feasible. The MPI scanner detects a tracer bolus of 2 ml Perimag® or 1.5 ml Resotran®. Imaging results are consistent and reproducible in three cadaveric leg phantoms. Conclusion: This study demonstrates, that the recently developed human-sized MPI scanner facilitates reliable radiation-free image guidance for peripheral vascular interventions in the superficial femoral artery with a tracer approved for use in humans.