JPJuozas Petruskevicius

Juozas Petruskevicius

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Juozas Petruskevicius has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Locking plate fixation compared with tension-band wiring for patellar fractures: a multicentre randomized controlled trial

    by Peter Larsen, Rikke Thorninger, Rasmus Pind Severinsen, Jens-Christian Beuke, Steffen Skov Jensen, Morten Kerri Rasmussen, Juozas Petruskevicius, Jeppe Barckman, Niels Henrik Bruun, Rasmus Elsoe

    Aims: Patellar fractures are associated with considerable postoperative morbidity, and tension-band wiring has high complication rates and suboptimal outcomes. Locking plate fixation is a recent surgical innovation which confers superior biomechanical stability. However, there is little information about the clinical outcomes of this method of treatment. The aim of this study was to compare locking plate fixation with tension-band wiring in patients requiring surgical treatment for a patellar fracture. Methods: In this patient- and assessor-blinded, multicentre randomized trial, 122 adults with a displaced patellar fracture were assigned 1:1 to locking plate fixation or tension-band wiring. The primary outcome was patient-reported knee function measured by the five sub-scales of the Knee Injury and Osteoarthritis Outcome Score (KOOS) at 12 months. Superiority was predefined as a statistically significant difference in at least three KOOS sub-scales exceeding the minimal clinically important difference (pain 10, symptoms 9, activities of daily living 6, sport and recreation 10, quality of life 10). Secondary outcomes included additional clinical and functional outcomes. Analyses were performed according to the intention-to-treat principle. Results: A total of 63 patients were assigned to locking plate fixation and 59 to tension-band wiring; 57 (90.5%) and 52 (88.1%), respectively, completed 12-month follow-up. Locking plate fixation resulted in statistically significant and clinically meaningful improvements in three KOOS sub-scales at this time: symptoms (mean difference -10.4 (95% CI -16.4 to -4.4)), sport and recreation (-14.1 (95% CI -24.7 to -3.4)), and quality of life (-10.9 (95% CI -19.0 to -2.7)). Removal of hardware, failure of fixation, and reoperation occurred more frequently after tension-band wiring. Conclusion: Locking plate fixation yielded superior patient-reported outcomes compared with tension-band wiring at 12 months, providing high-level evidence supporting the use of plate fixation as a preferred surgical technique for patients with a displaced patellar fracture. Cite this article: Bone Joint J 2026;108-B(9):1182–1189.

  • Open Access

    Disintegration of the Second‐Generation Precice Bone Transport Nail During Removal Is Still an Issue: A Case Report

    by Rikke Gravesen, Daniel Wæver, Juozas Petruskevicius, Jan Duedal Rölfing

    Background: Intramedullary bone transport nails (BTNs) have become an increasingly common method for managing bone defects. The Precice BTN (Globus Medical, Inc.) was previously associated with mechanical failures including intramedullary disintegration during elective nail removal. These issues were reportedly resolved in the second generation BTN. Results: Adhering to the CARE checklist, we describe a case involving a 23‐year‐old male with a posttraumatic bone defect following a motorcycle accident. He sustained a Gustilo–Anderson Type IIIB comminuted right fracture with a 5 cm bone defect. The leg was initially stabilized with external fixation. After several debridements, the fracture was internally stabilized using a regular trauma nail while the soft‐tissue defect was covered with a free flap and split‐thickness skin grafting. Subsequently, the 5 cm bone defect was managed using a second‐generation BTN. After 8 months, the patient underwent a planned nail removal according to the manufacturer′s instructions. Just as with the first‐generation BTN, the nail disintegrated within the medullary canal during the procedure and separated into multiple components. These internal components were cumbersomely removed using long forceps. Conclusion: Mechanical failure, specifically intramedullary disintegration, still occurs with the second‐generation BTN upon nail removal. The retention plug of the first‐generation BTN should thus be used despite instructions from the manufacturer that the problem has been solved in the current generation BTN. Appropriate instruments to manage potential nail disintegration should be present. The case underlines the need for further design improvements in future generations of BTN.

  • Resect or Retain Bone Fragments in Children and Teenagers with Severe Open Fractures?

    by Jan Duedal Rölfing, Mats Bue, Birgitte Kiil, Juozas Petruskevicius

    Case: A 14-year-old pedestrian was hit by a car and encountered similar bilateral Gustilo IIIB open tibial fractures. The right tibial fracture involved a large borderline vital butterfly fragment without periosteal contact, which was retained and proceeded to sufficient healing within 12 weeks. The left tibial fracture was treated according to the principles for the treatment of severe open fractures in adults, involving resection of devitalized fragments and bone transport, and healed within 15 months. Conclusions: Teenagers do possess larger bone healing potential than adults. Therefore, a rapid bone union can be achieved even with apparently devitalized bone fragments if sufficient soft-tissue closure and stable fracture fixation is established early in the treatment of open limb fractures.

  • Open Access

    Complex tibial fractures are associated with lower social classes and predict early exit from employment and worse patient-reported QOL: a prospective observational study of 46 complex tibial fractures treated with a ring fixator

    by Søren Kold, Peter Larsen, Juozas Petruskevicius, Rasmus Elsoe

    The long-term outcomes following complex fractures of the tibia are reported to carry a risk of knee pain, malalignment, articular injury and post-traumatic osteoarthritis. The main objective of this study was to account for the patient-reported quality of life (QOL) 12 months after ring fixator removal in patients with a complex tibial fracture. Secondary objectives included a review of the socio-economic characteristics of the patient group and the rate of return to work in the study period. A prospective follow-up study was conducted of 60 patients with complex fractures of the tibia treated with ring external fixation. Patient-reported outcomes, radiological outcomes and socio-economic status including employment status of the patients were obtained 12 months after frame removal. Forty-six patients completed the assessment 12 months after frame removal (77%). The mean age of the patient at the time of fracture was 54.6 years (range 31–86). There were 19 males and 27 females. At 12 months after frame removal, the mean EQ5D-5L index was 0.66 (CI 0.60–0.72). The mean EQ5D-5L VAS was 69 (CI 61–76). When this was compared to the established reference population from Denmark, the study population showed a significantly worse EQ5D-5L index. The majority of patients (87%) were in the lower social classes suggesting a higher degree of social deprivation in the study population. Twenty-seven per cent of patients who were employed prior to injury had returned to employment at approximately 19 months following fracture. The onset of post-traumatic osteoarthritis was present in the knee joint in 29% of patients following a proximal intra-articular fracture, whereas osteoarthritis was present at the ankle joint in 35% of patients following a distal intra-articular fracture 12 months after frame removal. This study indicates that at 12 months after frame removal there are poorer patient-reported QOL as when compared to reference populations. Furthermore, this study suggests that complex tibial fractures are associated with lower social classes and that only 27% of patients in this sample, who prior to injury were employed, had returned to employment at approximately 19 months after the injury.