Ahmad Azizpour
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ahmad Azizpour has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Dorela Hoxha
Pleione Energy S.A., Patriarchou Grigoriou & Neapoleos Str., 15310 Athens, Greece
1 shared publication - Ferry Kienberger
Keysight Laboratories, Keysight Technologies Austria GmbH, 4020 Linz, Austria
1 shared publication - Georg Gramse
Institute of Biophysics Johannes Kepler University Linz 4020 Austria
1 shared publication - Kim Verbeken
Ghent University, Ghent, Belgium
1 shared publication - Konstantinos Mylonas
Pleione Energy S.A., Patriarchou Grigoriou & Neapoleos Str., 15310 Athens, Greece
1 shared publication - Liese Vandewalle
Ghent University
1 shared publication
Latest Publications
- Open Access
- 9 October 2025
- Published by Springer Nature in Research Square
The Fingerprint method for analysis of thermal desorption spectra
The analysis of thermal desorption spectra (TDS) and the calculation of hydrogen detrapping activation energies rely on Gaussian peak deconvolution and Choo-Lee plot regression since 1982. However, this method imposes important assumptions about the number and shape of the TDS peaks used for fitting.In this study, we propose the fingerprint method, an alternative approach that eliminates these long-standing constraints. By applying the fingerprint analysis to eight TDS spectra from three different Fe-C model alloys, we demonstrate its exceptional sensitivity and ability to resolve activation energy distributions -- the material fingerprint -- unattainable with traditional methods. We further showcase by manual and automated analysis how the such obtained fingerprints can be used to uniquely distinguish the TDS spectra of each alloy independent of the heating rate. Thus the fingerprint method also increases experimental efficiency by reducing the amount of necessary heating rates for TDS down to one.
- 9 October 2025
- Published by Springer Nature in Research Square
Open AccessThe Fingerprint method for analysis of thermal desorption spectra
The analysis of thermal desorption spectra (TDS) and the calculation of hydrogen detrapping activation energies rely on Gaussian peak deconvolution and Choo-Lee plot regression since 1982. However, this method imposes important assumptions about the number and shape of the TDS peaks used for fitting.In this study, we propose the fingerprint method, an alternative approach that eliminates these long-standing constraints. By applying the fingerprint analysis to eight TDS spectra from three different Fe-C model alloys, we demonstrate its exceptional sensitivity and ability to resolve activation energy distributions -- the material fingerprint -- unattainable with traditional methods. We further showcase by manual and automated analysis how the such obtained fingerprints can be used to uniquely distinguish the TDS spectra of each alloy independent of the heating rate. Thus the fingerprint method also increases experimental efficiency by reducing the amount of necessary heating rates for TDS down to one.
- Open Access
Electrochemical Analysis of Carbon-Based Supercapacitors Using Finite Element Modeling and Impedance Spectroscopy
The electrochemical performance of carbon-based supercapacitors containing ionic liquid electrolytes was investigated through calibrated impedance spectroscopy and finite element modeling (FEM). To ensure precisely calibrated complex impedance measurements over a wide frequency range the measured pouch cells were mounted in a pressure fixture with stable terminal contacts, and a two-term impedance calibration workflow was applied. For the physical interpretation of the measurement results, FEM was used. Experimental findings demonstrated a clear dependency of the capacitive behavior on the electrode material, where cells with activated carbon electrodes showed lower impedance compared to cells with graphene electrodes. For FEM, we used a volume-averaged approach to study the effect of the electrode structure on the EIS response of the cells. The simulated impedance results showed a good agreement with experimental data in the middle- to high-frequency regions, ranging from 10 Hz to 10 kHz. Deviations from the ideal Warburg impedance were observed at lower frequencies, suggesting nonlinearity effects of the porous structure on ion transport mechanisms. FEM analysis was performed for both graphene and activated carbon electrodes showing a steeper transition region for activated carbon electrodes, indicating a reduced diffusion resistance for electrolyte ions.
Open AccessElectrochemical Analysis of Carbon-Based Supercapacitors Using Finite Element Modeling and Impedance Spectroscopy
The electrochemical performance of carbon-based supercapacitors containing ionic liquid electrolytes was investigated through calibrated impedance spectroscopy and finite element modeling (FEM). To ensure precisely calibrated complex impedance measurements over a wide frequency range the measured pouch cells were mounted in a pressure fixture with stable terminal contacts, and a two-term impedance calibration workflow was applied. For the physical interpretation of the measurement results, FEM was used. Experimental findings demonstrated a clear dependency of the capacitive behavior on the electrode material, where cells with activated carbon electrodes showed lower impedance compared to cells with graphene electrodes. For FEM, we used a volume-averaged approach to study the effect of the electrode structure on the EIS response of the cells. The simulated impedance results showed a good agreement with experimental data in the middle- to high-frequency regions, ranging from 10 Hz to 10 kHz. Deviations from the ideal Warburg impedance were observed at lower frequencies, suggesting nonlinearity effects of the porous structure on ion transport mechanisms. FEM analysis was performed for both graphene and activated carbon electrodes showing a steeper transition region for activated carbon electrodes, indicating a reduced diffusion resistance for electrolyte ions.