RRRaquel Gomes Rocha

Raquel Gomes Rocha

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Raquel Gomes Rocha has a total of 83 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Pencil-Drawn Electrode within Additively Manufactured Devices for Uric Acid Detection

    by Mariana C. Marra, Marina Di-Oliveira, Amanda B. Nascimento, Raquel G. Rocha, Natália C. de Moraes, Eduardo M. Richter, Bruno G. Lucca, Rodrigo A. A. Muñoz

    Disposable electrochemical sensors have attracted increasing attention as low-cost, portable, and environmentally friendly alternatives to conventional analytical methods. Pencil-drawn electrodes (PDEs) offer a simple and sustainable approach, allowing rapid fabrication without conductive inks, sophisticated equipment, or laborious procedures. Here, a PDE was prepared on a stereolithography-additive manufactured substrate assembled on a fused-filament fabrication (FFF) additively manufactured electrochemical cell applied for uric acid (UA) sensing. The electrode was characterized by SEM and Raman spectroscopy, confirming its surface morphology, conductivity, and electrochemical activity. The sensor can be produced at a very low cost using nontoxic and readily available materials, making it suitable for point-of-care applications. The sensor demonstrated good reproducibility, stability, and selectivity, and exhibited electrochemical performance comparable to glassy-carbon electrodes (GCE) and carbon screen-printed electrodes (C-SPE) without any surface pretreatment. The analytical performance of the PDE was evaluated for UA, showing a linear response in the concentration range of 5.0–40.0 μmol L–1, with a detection limit (LOD) of 0.2 μmol L–1. Finally, it was successfully applied to the determination of UA in synthetic samples. Overall, this study presents a low-cost, eco-friendly, and reliable platform, highlighting the potential of PDEs on additively manufactured platforms for sustainable and accessible analytical chemistry.

  • Open Access

    Green approaches toward sustainable materials for electrochemical sensors

    by Raquel G. Rocha, Gilvana P. Siqueira, Eduardo M. Richter, Rodrigo A.A. Muñoz, Wallans T.P. dos Santos


  • Electrochemical quantification of condensed tannins in extracts and herbal medicines using 3D-printed electrodes

    by Dayane Vasconcelos Petine, Diego Godina Prado, Mariana Cardoso Marra, Raquel Gomes Rocha, Nélio Inácio Gravata Inoque, Mário Machado Martins, Robert D. Crapnell, Craig E. Banks, Alberto de Oliveira, Rodrigo Alejandro Abarza Munoz, et al.

    A 3D-printed carbon-based electrode within a 3D-printed cell can be used to quantify condensed tannins in extracts and herbal medicines after proper electrode surface treatment and sample preparation steps.


  • Top Cited Papers

    From conductive filament design to 3D-printed devices: a critical review and development guide for advanced electrochemical applications

    by Raquel G. Rocha, Gilvana P. Siqueira, Ana C. M. C. M. Oliveira, Elena Bernalte, Robert D. Crapnell, Agata Rodak, Krzysztof Formela, Mateusz Cieślik, Craig E. Banks, Eduardo Mathias Richter, et al.

    Tutorial guide and critical review on conductive 3D-printing filaments for advanced electrochemical devices.


  • Open Access

    Electrochemical Sensor Based on a Composite of Babassu Starch, Carbon Black, and Cobalt Phthalocyanine for the Detection of Hydroxychloroquine

    by João Pedro C. Silva, Gilvana P. Siqueira, Domingos Rosa Santos-Neto, Raquel G. Rocha, Jéssica S. Stefano, Luiza M. F. Dantas, Luiz Ricardo G. Silva, Eduardo M. Richter, Rodrigo A. A. Muñoz, Iranaldo S. da Silva

    This work presents the development of an electrochemical sensor based on a starch film extracted from the Babassu coconut mesocarp flour, carbon black (CB), and cobalt phthalocyanine. Scanning-electron microscopy coupled with energy-dispersive spectroscopy confirmed the presence of each component in composite, by confirming alteration of surface morphology and composition. Raman and Fourier-transform infrared spectroscopy also evidenced surface alteration while atomic-force microscopy revealed increase in rugosity after insertion of CB and cobalt phthalocyanine. The developed sensor was applied for the determination of hydroxychloroquine (HCQ) in both environmental and pharmaceutical (tablet) samples, using linear sweep voltammetry and a 0.1 mol L–1 phosphate buffer solution (pH = 7.0) as the supporting electrolyte. The method achieved impressive detectability in comparison with literature, with limits of detection (LOD) and quantification (LOQ) of 0.015 μmol L–1 and 0.052 μmol L–1, respectively. Recovery studies conducted in pharmaceutical matrices, tap water, and treated water samples yielded values ranging from 100% to 105%, demonstrating the sensor’s accuracy. Notably, no electrode fouling was observed after HCQ oxidation, confirming the stability of the modified electrode. These findings underscore the potential of this sensor for environmental monitoring and highlight starch as a sustainable alternative material for immobilizing modifiers on electrodes.


  • Open Access

    Electrochemical detection and oxidation pathway of fenproporex using 3D-printed electrodes in dietary and biological samples

    by Isabella C.O.F. Silva, Raquel G. Rocha, Amanda B. Nascimento, Raquel M.F. Sousa, Clésia C. Nascentes, Robert D. Crapnell, Craig E. Banks, Rodrigo A.A. Muñoz, Eduardo M. Richter

  • Open Access

    Solvent-Assisted Modification of Laser-Induced Graphene for Surface-Enhanced Electrochemical Response

    by Nélio I. G. Inoque, Raquel G. Rocha, Gilvana P. Siqueira, Ana Clara Maia Oliveira, Michele V. C. O. Da Silva, Robert D. Crapnell, Craig E. Banks, Edson Nossol, Eduardo Mathias Richter, Rodrigo A. A. Muñoz

    The fabrication and application of laser-induced graphene (LIG) have received significant interest across various research fields, particularly in sensing technologies. Herein, we investigated the surface modification of LIG electrodes with different solvents and demonstrated that dimethyl sulfoxide (DMSO) enhances their electrochemical activity. Importantly, our findings reveal that solvent treatments themselves can induce significant modifications on the electrode surface (e.g., changes in functional groups, wettability, and morphology), which must be carefully considered in sensor design and optimization. The application of a microliter aliquot of DMSO to the LIG surface significantly altered its wettability, promoting a transition to hydrophilic behavior, which was verified by contact-angle measurements. AFM and XRD results indicate that DMSO treatment promotes the rearrangement of disordered carbon atoms, minimizing localized structural defects and enabling more efficient π-π stacking between graphene sheets. The cyclic voltammetric response of the [Fe(CN)6]3-/4- redox probe showed a 3-fold increase in peak current. The enhanced electrochemical effect of DMSO surface changes on LIG electrodes was also confirmed in the presence of several organic species, and a substantial current increase was verified by the effect of DMSO. As proof-of-concept, the antibiotic sulfanilamide was detected in synthetic urine and water samples using differential-pulse voltammetry on DMSO-treated LIG. Under optimized conditions, the sensor exhibited a linear response in the range of 0.3-9.0 μmol L-1 with a limit of detection of 0.09 μmol L-1 and satisfactory recovery values (90-104%).


  • Open Access

    Enhanced voltammetric detection of antioxidants using plasma-activated laser-induced graphene electrodes

    by António B. Tivana, Nélio I. G. Inoque, Anastácio A. Boane, Marina Di-Oliveira, Dianderson C. M. Ferreira, Raquel G. Rocha, Raquel M. F. Sousa, Robert D. Crapnell, Craig E. Banks, Eduardo M. Richter, et al.

    Plasma activation of laser-induced graphene electrodes improves voltammetric sensing. The antioxidant butyl hydroxyanisole (BHA) served as a proof-of-concept analyte.

  • Open Access

    Robotic Plasma System for Rapid Activation of Mass-Produced Electrochemical Sensors

    by Marina Di-Oliveira, Mariana C. Marra, Raquel G. Rocha, Teodoro R. Terra, Rodrigo A. A. Muñoz, Eduardo M. Richter

    Polishing, cleaning, and activation of solid electrode surfaces are common in electrochemistry; however, they are often labor-intensive, operator-dependent, and poorly reproducible. In the context of large-scale production of disposable solid-state sensors, such as screen-printed electrodes (SPEs), traditional surface conditioning procedures have proven to be impractical and incompatible with automated workflows. Here, we report the development of a low-cost robotic system that integrates a Tesla coil-based air-plasma generator with a Python-controlled XY motion platform for rapid (∼15 s per 0.11 cm2) and reproducible surface activation of SPEs. The main novelty of this study lies in the mechanization and reproducibility of the plasma activation process, achieved through the integration of a robotic platform with an air-plasma generator to enable standardized and scalable electrode conditioning. Morphological and Raman spectroscopic analyses revealed significant surface restructuring after plasma activation, leading to reduced charge-transfer resistance (from 7.10 to 0.45 kΩ), increased electron-transfer kinetics (∼4-fold increase in k0), increased electroactive area (from 0.073 to 0.270 cm2), and improved interelectrode reproducibility (RSD from 9.7 to 0.8%). The treatment also restored the voltammetric performance of carbon, gold, and platinum SPEs stored for over ten years. Plasma-treated carbon SPEs enabled the voltammetric determination of picric acid in simulated explosive samples (linear range: 0.5-50.0 μmol L-1; LOD: 0.1 μmol L-1). Moreover, 3D-printed electrodes were also successfully treated by using this system. This robotic plasma system provides a low-cost, scalable, and ecofriendly strategy for standardized activation of disposable electrodes, enhancing or restoring their electrochemical performance for routine analytical and industrial applications.


  • Open Access

    Blue‐Laser Ablation Treatment of Fully Integrated 3D‐Printed Flexible Electrochemical Sensing Device

    by Amanda B. Nascimento, Mayane S. Carvalho, Raquel G. Rocha, Eduardo M. Richter, Osmando F. Lopes, Michele Abate, Nicolò Dossi, Rodrigo A. A. Muñoz

    3D printing, particularly fused deposition modeling, is an important technology applied in the electrochemical field and typically requires surface activation procedures to remove excess of polymeric material and expose the conductive material. The laser ablation method presents advantages, such as low cost, speed, and elimination of chemicals. In this context, this study aims to investigate the modification of graphene/polylactic acid electrode (Gp/PLA) using blue‐laser treatment for the improved detection of paracetamol (PAR). 2D Gp/PLA printed layers were deposited on an insulating polycaprolactone substrate to generate a compact three‐electrode system in a planar configuration for microliter‐drop analysis. The blue‐laser‐treated electrodes (BL) were obtained using optimized conditions of laser power and speed of 280 mW and 30 mm s−1, respectively. The Gp/PLA‐BL electrode was characterized by Fourier transform infrared (FTIR) spectroscopy, scanning electron microscopy (SEM), Raman spectroscopy, and X‐ray photoelectron spectroscopy (XPS). The SEM images showed the removal of PLA, which was also confirmed by FTIR and XPS spectra. Before the treatment, cyclic voltammograms at 50 mV s−1 of inner‐sphere [Fe(CN)6]3−/4− redox pair exhibited an ill‐defined voltammetric profile (ΔEp = 502 ± 4 mV) while an increase in the reversibility was achieved (ΔEp = 120 ± 1 mV) after the blue‐laser ablation. Additionally, the lower charge transfer resistance was measured by electrochemical impedance spectroscopy after the treatment. As a proof‐of‐concept, analytical curves were constructed for PAR detection in a single drop using both non‐treated and treated printed electrodes. An increase in the sensitivity of 2.4‐fold was observed after the treatment.