Li Wei
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Li Wei has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Rui Cheng
Department of Ultrasound, XinHua Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China
4 shared publications - Yi Dong
Department of Ultrasound, Xinhua Hospital Affiliated to Shanghai Jiaotong University School of Medicine, Shanghai 200082, China
4 shared publications - Ying Wang
Department of Ultrasound, XinHua Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China
4 shared publications - Yunlin Huang
Department of Ultrasound Xinhua Hospital Affiliated to Shanghai Jiao Tong University School of Medicine Shanghai China
4 shared publications - Juan Cheng
Department of Ultrasound, XinHua Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China
3 shared publications - Shiwen Wang
Department of Ultrasound, XinHua Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China
3 shared publications
Latest Publications
- Open Access
- 1 September 2026
- Published by Korean Society of Ultrasound in Medicine in Ultrasonography
- Vol. 45 (5) , 426-438
Quantitative liver ultrasound: current status and challenges
Ultrasound is the most widely used imaging modality for liver evaluation because it is accessible, portable, affordable, and repeatable. Quantitative liver ultrasound should therefore be understood not as a single technology, but as a set of biomarker strategies at different stages of development. Ultrasound elastography is the most mature component of this field and has been incorporated into noninvasive pathways for fibrosis assessment. Ultrasound-based liver fat quantification is also advancing rapidly through attenuation, backscatter, and radiofrequency-based techniques. A newer area of investigation involves the evaluation of viscoelasticity and inflammatory activity using shear-wave dispersion and related biomarkers, particularly in metabolic dysfunction-associated steatotic liver disease. The future value of quantitative liver ultrasound will depend on integrating multiple parameters to support clinical triage, monitoring, and, increasingly, treatment decision-making.
- 1 September 2026
- Published by Korean Society of Ultrasound in Medicine in Ultrasonography
- Vol. 45 (5) , 426-438
Open AccessQuantitative liver ultrasound: current status and challenges
Ultrasound is the most widely used imaging modality for liver evaluation because it is accessible, portable, affordable, and repeatable. Quantitative liver ultrasound should therefore be understood not as a single technology, but as a set of biomarker strategies at different stages of development. Ultrasound elastography is the most mature component of this field and has been incorporated into noninvasive pathways for fibrosis assessment. Ultrasound-based liver fat quantification is also advancing rapidly through attenuation, backscatter, and radiofrequency-based techniques. A newer area of investigation involves the evaluation of viscoelasticity and inflammatory activity using shear-wave dispersion and related biomarkers, particularly in metabolic dysfunction-associated steatotic liver disease. The future value of quantitative liver ultrasound will depend on integrating multiple parameters to support clinical triage, monitoring, and, increasingly, treatment decision-making.
- Open Access
- 5 March 2026
- Published by Wiley in Portal Hypertension & Cirrhosis
- Vol. 5 (2) , 117-128
Fast Quantitative Evaluation of the Amelioration Effect in MASLD During Semaglutide Treatment Using Ultrasound‐Derived Fat Fraction and Fat‐to‐Muscle Ratio
Aims: Metabolic dysfunction‐associated steatotic liver disease (MASLD) is a chronic liver disease closely associated with metabolic dysfunction. Research into a feasible, rapid, and effective assessment method is crucial for evaluating the therapeutic effects of semaglutide in MASLD. This study aims to explore the fast quantitative evaluation of the amelioration effect in MASLD during semaglutide therapy using ultrasound‐derived fat fraction (UDFF) and fat‐to‐muscle ratio (FMR). Methods: This prospective study enrolled patients diagnosed with MASLD who were planned to be treated with subcutaneous injection of semaglutide. All patients underwent UDFF measurements (six acquisitions for each patient) using the Acuson Sequoia ultrasound system (Siemens Healthineers, Mountain View, USA) to assess hepatic steatosis before and 14 ± 2 weeks after treatment. Body composition (body weight, visceral fat area, percent body fat, waist circumference, waist‐to‐hip ratio, skeletal muscle mass index, and FMR) was analyzed by phase‐sensitive bio‐impedance. FMR was obtained to evaluate the ratio of fat mass to skeletal muscle mass. The Spearman correlation was performed to compare clinical, ultrasound parameters, and serum biomarkers. Results: From July 2023 to June 2024, 22 patients (77.3% female) were included, with a median body mass index of 32.6 kg/m 2 . Semaglutide treatment resulted in a median weight loss of 7.5 kg from baseline. Most patients (19/22, 86.3%) achieved a significant weight reduction (weight loss ≥ 5%). Specifically, four patients had a weight loss of ≥ 5% and < 7%, nine patients had a weight loss of ≥ 7% and < 10%, and six patients had a weight loss of ≥ 10%. UDFF values were significantly decreased at follow‐up compared with those at baseline (9.4% vs. 21.8%; p < 0.001) and reached the highest reduction (49.4%). UDFF values were positively correlated with body composition at baseline ( r = 0.33–0.54) and follow‐up ( r = 0.30–0.65). The reduction of FMR (13.1%) was the second highest among body composition measures, after that of visceral fat area (17.3%). FMR values had a high correlation with visceral fat area at both baseline and follow‐up ( r = 0.70 and r = 0.80, respectively, both p < 0.001). Conclusion: UDFF and FMR values could be used as fast quantitative tools for assessing hepatic steatosis and myosteatosis in MASLD during semaglutide therapy.
- 5 March 2026
- Published by Wiley in Portal Hypertension & Cirrhosis
- Vol. 5 (2) , 117-128
Open AccessFast Quantitative Evaluation of the Amelioration Effect in MASLD During Semaglutide Treatment Using Ultrasound‐Derived Fat Fraction and Fat‐to‐Muscle Ratio
Aims: Metabolic dysfunction‐associated steatotic liver disease (MASLD) is a chronic liver disease closely associated with metabolic dysfunction. Research into a feasible, rapid, and effective assessment method is crucial for evaluating the therapeutic effects of semaglutide in MASLD. This study aims to explore the fast quantitative evaluation of the amelioration effect in MASLD during semaglutide therapy using ultrasound‐derived fat fraction (UDFF) and fat‐to‐muscle ratio (FMR). Methods: This prospective study enrolled patients diagnosed with MASLD who were planned to be treated with subcutaneous injection of semaglutide. All patients underwent UDFF measurements (six acquisitions for each patient) using the Acuson Sequoia ultrasound system (Siemens Healthineers, Mountain View, USA) to assess hepatic steatosis before and 14 ± 2 weeks after treatment. Body composition (body weight, visceral fat area, percent body fat, waist circumference, waist‐to‐hip ratio, skeletal muscle mass index, and FMR) was analyzed by phase‐sensitive bio‐impedance. FMR was obtained to evaluate the ratio of fat mass to skeletal muscle mass. The Spearman correlation was performed to compare clinical, ultrasound parameters, and serum biomarkers. Results: From July 2023 to June 2024, 22 patients (77.3% female) were included, with a median body mass index of 32.6 kg/m 2 . Semaglutide treatment resulted in a median weight loss of 7.5 kg from baseline. Most patients (19/22, 86.3%) achieved a significant weight reduction (weight loss ≥ 5%). Specifically, four patients had a weight loss of ≥ 5% and < 7%, nine patients had a weight loss of ≥ 7% and < 10%, and six patients had a weight loss of ≥ 10%. UDFF values were significantly decreased at follow‐up compared with those at baseline (9.4% vs. 21.8%; p < 0.001) and reached the highest reduction (49.4%). UDFF values were positively correlated with body composition at baseline ( r = 0.33–0.54) and follow‐up ( r = 0.30–0.65). The reduction of FMR (13.1%) was the second highest among body composition measures, after that of visceral fat area (17.3%). FMR values had a high correlation with visceral fat area at both baseline and follow‐up ( r = 0.70 and r = 0.80, respectively, both p < 0.001). Conclusion: UDFF and FMR values could be used as fast quantitative tools for assessing hepatic steatosis and myosteatosis in MASLD during semaglutide therapy.
- Open Access
- 1 January 2026
- Published by Korean Society of Ultrasound in Medicine in Ultrasonography
- Vol. 45 (1) , 48-58
Diagnostic performance of ultrasound-derived fat fraction for assessing steatotic liver disease with histopathology as the reference
Purpose: This study was performed to evaluate the diagnostic performance of ultrasound-derived fat fraction (UDFF) for detecting hepatic steatosis in patients with steatotic liver disease (SLD), using liver biopsy and histopathology as the gold standard.Methods: In this prospective study, patients referred for evaluation of suspected SLD were enrolled. All patients underwent UDFF and controlled attenuation parameter (CAP) measurements. Histopathological findings were assessed using the steatosis-activity-fibrosis scoring system as the gold standard. Pearson or Spearman correlation analyses and multivariate linear regression were performed. Areas under the receiver operating characteristic curves (AUCs) were utilized to assess the diagnostic performance of UDFF and CAP in identifying hepatic steatosis. The DeLong test was used to compare AUCs. Results: From February 2023 to May 2025, 66 patients were included. The median body mass index was 24 kg/m2. UDFF was positively correlated with hepatic steatosis grade (r=0.66). Using UDFF thresholds of 9.5%, 14.5%, and 16.3% (determined by the Youden index), the AUCs for detecting steatosis grades ≥S1, ≥S2, and S3 were 0.82, 0.90, and 0.99, respectively. UDFF exhibited a significantly higher AUC than CAP for detecting steatosis grade S3 (P=0.037). UDFF was correlated with hepatic steatosis grade, activity grade, CAP, aspartate aminotransferase level, and albumin level (all P<0.05). Conclusion: UDFF demonstrated good diagnostic performance for assessing hepatic steatosis, using histopathology as the reference. UDFF may serve as a quantitative imaging approach to measure liver fat content in patients with SLD.
- 1 January 2026
- Published by Korean Society of Ultrasound in Medicine in Ultrasonography
- Vol. 45 (1) , 48-58
Open AccessDiagnostic performance of ultrasound-derived fat fraction for assessing steatotic liver disease with histopathology as the reference
Purpose: This study was performed to evaluate the diagnostic performance of ultrasound-derived fat fraction (UDFF) for detecting hepatic steatosis in patients with steatotic liver disease (SLD), using liver biopsy and histopathology as the gold standard.Methods: In this prospective study, patients referred for evaluation of suspected SLD were enrolled. All patients underwent UDFF and controlled attenuation parameter (CAP) measurements. Histopathological findings were assessed using the steatosis-activity-fibrosis scoring system as the gold standard. Pearson or Spearman correlation analyses and multivariate linear regression were performed. Areas under the receiver operating characteristic curves (AUCs) were utilized to assess the diagnostic performance of UDFF and CAP in identifying hepatic steatosis. The DeLong test was used to compare AUCs. Results: From February 2023 to May 2025, 66 patients were included. The median body mass index was 24 kg/m2. UDFF was positively correlated with hepatic steatosis grade (r=0.66). Using UDFF thresholds of 9.5%, 14.5%, and 16.3% (determined by the Youden index), the AUCs for detecting steatosis grades ≥S1, ≥S2, and S3 were 0.82, 0.90, and 0.99, respectively. UDFF exhibited a significantly higher AUC than CAP for detecting steatosis grade S3 (P=0.037). UDFF was correlated with hepatic steatosis grade, activity grade, CAP, aspartate aminotransferase level, and albumin level (all P<0.05). Conclusion: UDFF demonstrated good diagnostic performance for assessing hepatic steatosis, using histopathology as the reference. UDFF may serve as a quantitative imaging approach to measure liver fat content in patients with SLD.
- Open Access
- 1 March 2025
- Published by Korean Society of Ultrasound in Medicine in Ultrasonography
- Vol. 44 (2) , 134-144
Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Purpose: This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard.Methods: Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated.Results: Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001).Conclusion: Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD.
- 1 March 2025
- Published by Korean Society of Ultrasound in Medicine in Ultrasonography
- Vol. 44 (2) , 134-144
Open AccessUltrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Purpose: This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard.Methods: Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated.Results: Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001).Conclusion: Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD.