Yang Lu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yang Lu has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
Liandong Yu
4 shared publicationsRongke Gao
4 shared publicationsYongan Wen
4 shared publicationsFeifei Wang
3 shared publicationsXiaozhe Chen
3 shared publicationsZihao Wang
3 shared publications
Latest Publications
- 6 August 2026
- Published by Elsevier in Optics and Lasers in Engineering
- Vol. 206
Direct label-free classification of prostate cancer cells from holographic microscopic imaging flow cytometry
- 6 August 2026
- Published by Elsevier in Optics and Lasers in Engineering
- Vol. 206
Direct label-free classification of prostate cancer cells from holographic microscopic imaging flow cytometry
- 17 June 2026
- Published by Elsevier in Optics & Laser Technology
- Vol. 203
SNR-enhanced ϕ-OTDR using polarization fusion based frequency division phase-matching method
- 17 June 2026
- Published by Elsevier in Optics & Laser Technology
- Vol. 203
SNR-enhanced ϕ-OTDR using polarization fusion based frequency division phase-matching method
- 5 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (12) , 19229-19238
3-D Measurement of Precision Parts in Complex Environments Based on Line Structured Light and Deep Learning
Line structured light scanning is widely used for the three-dimensional (3D) measurement of precision parts, essentially relying on the optical sensing of laser stripe information by a camera. However, for metal parts, the large curvature and specular reflection of their surfaces can introduce significant noise, reducing the stability of laser stripe perception and thus hindering the accurate extraction of the laser centerline. In order to overcome these challenges, a deep learning-driven algorithm is proposed. An attention mechanism is incorporated into the original U-Net architecture, and the encoder is modified to achieve precise laser stripe segmentation. Subsequently, the region of interest (ROI) is extracted, followed by the application of the Steger algorithm for laser stripe centerline extraction, with the extracted results further refined through non-maximum suppression (NMS), interpolation, and smoothing techniques. The experimental results indicate that, under complex perception environments, a maximum standard deviation (SD) of 0.006 mm, a maximum root mean square error (RMSE) of 0.006 mm, and a maximum absolute percentage error (APE) of 0.069% are achieved by the proposed method. These findings validate the high accuracy and stability of the scheme, especially under high curvature, reflective surfaces, and strong ambient lighting conditions.
- 5 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (12) , 19229-19238
3-D Measurement of Precision Parts in Complex Environments Based on Line Structured Light and Deep Learning
Line structured light scanning is widely used for the three-dimensional (3D) measurement of precision parts, essentially relying on the optical sensing of laser stripe information by a camera. However, for metal parts, the large curvature and specular reflection of their surfaces can introduce significant noise, reducing the stability of laser stripe perception and thus hindering the accurate extraction of the laser centerline. In order to overcome these challenges, a deep learning-driven algorithm is proposed. An attention mechanism is incorporated into the original U-Net architecture, and the encoder is modified to achieve precise laser stripe segmentation. Subsequently, the region of interest (ROI) is extracted, followed by the application of the Steger algorithm for laser stripe centerline extraction, with the extracted results further refined through non-maximum suppression (NMS), interpolation, and smoothing techniques. The experimental results indicate that, under complex perception environments, a maximum standard deviation (SD) of 0.006 mm, a maximum root mean square error (RMSE) of 0.006 mm, and a maximum absolute percentage error (APE) of 0.069% are achieved by the proposed method. These findings validate the high accuracy and stability of the scheme, especially under high curvature, reflective surfaces, and strong ambient lighting conditions.
- 20 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-10
Physics-Informed Frequency-Domain Pixel Super-Resolution for Fourier Single-Pixel Detection
Fourier single-pixel detection (FSPD) suffers from an inherent trade-off between spatial resolution and detection efficiency. This constraint significantly impacts measurement precision in optical instrumentation applications. To overcome these measurement limitations, we propose a frequency-domain super-resolution network based on physical measurement principles tailored for FSPD instruments. This method decomposes the frequency domain into magnitude and phase branches with targeted optimization strategies based on Fourier imaging distribution characteristics, while leveraging the physical sparse measurement priors of FSPD frequency sampling to enhance detection accuracy and measurement noise suppression. The network utilizes residual dense blocks for low-frequency measurement stability and combines self-attention mechanisms with non-local blocks for high-frequency detail detection. By integrating measurement consistency constraints and physics-informed frequency weighting based on FSPD’s inherent sampling characteristics, the proposed approach achieves superior measurement reconstruction accuracy. The physical measurement priors in the frequency domain are used to constrain the structural consistency of the super-resolution detection process. A multi-loss function with physical measurement constraints balances spectral fidelity and measurement consistency. Experiments demonstrate that under 128×128 resolution under-sampling detection, we achieved 256×256 resolution high-accuracy measurements. Moreover, at the same resolution, high-precision detection has been achieved for challenging measurement scenarios, such as A4 paper reflective media, which are difficult to reconstruct with traditional FSPD instruments, advancing practical measurement applications including precision microscopy detection and scattering measurement systems.
- 20 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-10
Physics-Informed Frequency-Domain Pixel Super-Resolution for Fourier Single-Pixel Detection
Fourier single-pixel detection (FSPD) suffers from an inherent trade-off between spatial resolution and detection efficiency. This constraint significantly impacts measurement precision in optical instrumentation applications. To overcome these measurement limitations, we propose a frequency-domain super-resolution network based on physical measurement principles tailored for FSPD instruments. This method decomposes the frequency domain into magnitude and phase branches with targeted optimization strategies based on Fourier imaging distribution characteristics, while leveraging the physical sparse measurement priors of FSPD frequency sampling to enhance detection accuracy and measurement noise suppression. The network utilizes residual dense blocks for low-frequency measurement stability and combines self-attention mechanisms with non-local blocks for high-frequency detail detection. By integrating measurement consistency constraints and physics-informed frequency weighting based on FSPD’s inherent sampling characteristics, the proposed approach achieves superior measurement reconstruction accuracy. The physical measurement priors in the frequency domain are used to constrain the structural consistency of the super-resolution detection process. A multi-loss function with physical measurement constraints balances spectral fidelity and measurement consistency. Experiments demonstrate that under 128×128 resolution under-sampling detection, we achieved 256×256 resolution high-accuracy measurements. Moreover, at the same resolution, high-precision detection has been achieved for challenging measurement scenarios, such as A4 paper reflective media, which are difficult to reconstruct with traditional FSPD instruments, advancing practical measurement applications including precision microscopy detection and scattering measurement systems.
- 16 March 2025
- Published by Elsevier in Optics & Laser Technology
- Vol. 187
Optimizing Under-Sampling in Fourier Single-Pixel imaging using GANs and attention mechanisms
- 16 March 2025
- Published by Elsevier in Optics & Laser Technology
- Vol. 187
Optimizing Under-Sampling in Fourier Single-Pixel imaging using GANs and attention mechanisms