Yiyang Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yiyang Liu has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Chen Deng
National Key Laboratory of Electromagnetic Energy, Naval University of Engineering, Wuhan, China
1 shared publication - Jinyang Han
National Key Laboratory of Electromagnetic Energy, Naval University of Engineering, Wuhan, China
1 shared publication - Liang Zhou
National Key Laboratory of Electromagnetic Energy, Naval University of Engineering, Wuhan, China
1 shared publication - Weichao Li
Naval University of Engineering
1 shared publication Xianglin Zhao
School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan, China
1 shared publicationZhennan Yang
National Key Laboratory of Electromagnetic Energy, Naval University of Engineering, Wuhan, China
1 shared publication
Latest Publications
- 3 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (5) , 6476-6491
Output Voltage Chopping Compensation Control Method and Current Fluctuation Suppression Strategy for High-Rate Discharge LBESS
The lithium battery energy storage system (LBESS) can provide short-term high power and long-term high energy for electromagnetic launch system through high-rate discharge. However, the high-rate discharge LBESS has the problems of output voltage drop and current low-frequency fluctuation in the high-voltage and high-power launch process. This article introduces an energy storage system topology with N+1-level dynamic chopping converter, which can realize dynamic compensation of output voltage. To promote the rapidity of output voltage compensation, an improved active disturbance rejection control method by designing the variable gain (VG) control law with initial small gain is proposed to suppress the initial peak of total disturbance observation, thus improving the response speed of VG-ADRC controller. In order to decrease the dc current fluctuation, a nonlinear extended state observer with a muti-cascade notch filter is designed to attenuate the low-frequency components in total disturbance observation, the reference current is adjusted in real-time, thereby greatly suppressing the fluctuation amplitude of output current. Moreover, the frequency analysis shows that the proposed method does not introduce the negative phase into the loop transfer function and affect the stability of the original system. Finally, a 10 MW peak power pulsed discharge experimental platform was built to verify the effectiveness and practicability of the proposed strategies.
- 3 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (5) , 6476-6491
Output Voltage Chopping Compensation Control Method and Current Fluctuation Suppression Strategy for High-Rate Discharge LBESS
The lithium battery energy storage system (LBESS) can provide short-term high power and long-term high energy for electromagnetic launch system through high-rate discharge. However, the high-rate discharge LBESS has the problems of output voltage drop and current low-frequency fluctuation in the high-voltage and high-power launch process. This article introduces an energy storage system topology with N+1-level dynamic chopping converter, which can realize dynamic compensation of output voltage. To promote the rapidity of output voltage compensation, an improved active disturbance rejection control method by designing the variable gain (VG) control law with initial small gain is proposed to suppress the initial peak of total disturbance observation, thus improving the response speed of VG-ADRC controller. In order to decrease the dc current fluctuation, a nonlinear extended state observer with a muti-cascade notch filter is designed to attenuate the low-frequency components in total disturbance observation, the reference current is adjusted in real-time, thereby greatly suppressing the fluctuation amplitude of output current. Moreover, the frequency analysis shows that the proposed method does not introduce the negative phase into the loop transfer function and affect the stability of the original system. Finally, a 10 MW peak power pulsed discharge experimental platform was built to verify the effectiveness and practicability of the proposed strategies.