BYBo Yang

Bo Yang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Bo Yang has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Optimization of Polymer Sieving Matrix Composition for DNA Fragment Separation in a Laboratory-Built Multicapillary Electrophoresis System

    by Bo Yang, Ping Wang, Wentian Li, Xuanye Wei, Wenqian Bi, Chele Mugong, Sicheng Ye, Yunchong Jiang, Yoshinori Yamaguchi, Zhenqing Li

    Capillary electrophoresis (CE) is widely used for DNA fragment analysis, but its separation performance depends strongly on the composition of the polymer sieving matrix, especially in multicapillary systems where matrix operability and reproducibility are critical. Herein, a laboratory-built multicapillary electrophoresis system was used to optimize the sieving matrix for high-throughput DNA fragment separation. The system integrated twelve fused-silica capillaries, high-voltage electrokinetic injection, fluorescence detection, and digital electropherogram acquisition. Using a 100 bp DNA ladder as the model sample, the effects of poly(ethylene oxide) (PEO), Tween 20, and glycerol on electropherogram quality were systematically investigated. PEO concentration was the dominant factor controlling the dynamic sieving network: 0.1% PEO provided insufficient separation, whereas 0.8–1.0% PEO produced clearly resolved DNA peaks. Tween 20 improved peak regularity and electropherogram quality under the tested conditions, with 0.05% providing sufficient improvement without prolonging migration time. Glycerol affected peak distribution by increasing apparent migration resistance in the polymer matrix; however, excessive glycerol slowed DNA migration and markedly extended the separation window. Considering separation quality, matrix operability, and analytical efficiency, 1.0% PEO, 0.05% Tween 20, 2.5% glycerol, 1× SYBR Gold, and 0.5× TBE were selected as the optimized sieving matrix. Under the optimized matrix, inter-capillary migration-time alignment improved the consistency of parallel capillary outputs, with corrected migration-time RSD values generally below 0.5%. The optimized formulation provides a practical basis for high-throughput CE-based DNA fragment analysis.

  • Open Access

    Capillary Electrophoresis in RNA Therapeutics: Toward a Core Analytical Platform for Development, Release Testing, and Process Analytics

    by Bo Yang, Xuanye Wei, Wenqian Bi, Chele Mugong, Sicheng Ye, Yunchong Jiang, Yoshinori Yamaguchi, Zhenqing Li

    The rapid expansion of RNA therapeutics requires analytical methods that resolve molecular integrity, heterogeneity, and process-related impurities. Capillary electrophoresis (CE) provides direct RNA separation with low sample consumption and can be coupled with laser-induced fluorescence (LIF) or mass spectrometry (MS). This review assesses CE across RNA therapeutic development, release testing, and process analytics. We examine CE separation methods and platform formats for mRNA integrity and poly(A) tail analysis, size- and structure-related impurity profiling, circular RNA purity evaluation, RNA modification analysis by CE-MS, and aptamer discovery. We also discuss multi-capillary systems, microchip electrophoresis (MCE), automation, artificial intelligence (AI)-assisted data analysis, and bioprocess integration. CE is already highly useful for selected quality control tasks, especially mRNA integrity, poly(A) tail profiling, and circular RNA purity, but broader routine adoption requires improved sensitivity, standardization, method transfer, and regulatory acceptance.

  • Open Access

    An Oscillating-Flow Microfluidic PCR Method for Rapid and Flexible Detection of Periodontal Pathogens

    by Zhenqing Li, Yueqing Wang, Bo Yang, Jing Yang, Yuan Zeng, Shinichi Sekine, Yoshinori Yamaguchi

    Polymerase chain reaction (PCR) is widely regarded as the gold standard for nucleic acid analysis; however, conventional thermal cycling limits its applicability in rapid and compact analytical systems. Here, we report an oscillating-flow microfluidic PCR method that enables rapid and flexible amplification by repeatedly shuttling the reaction mixture between two fixed-temperature zones. Unlike continuous-flow PCR, the proposed approach decouples PCR cycle number from microchannel geometry, allowing programmable cycling while reducing chip footprint. To enhance analytical reliability, polymer-assisted surface passivation using polyvinylpyrrolidone was employed to suppress nonspecific adsorption in polydimethylsiloxane (PDMS) microchannels, significantly improving amplification efficiency. Using Porphyromonas gingivalis and Treponema denticola as representative periodontal pathogens, 35-cycle amplification was completed within 20 min with reliable product yield. The proposed method advances oscillating-flow PCR toward a robust analytical strategy for rapid pathogen detection and related microfluidic nucleic acid analysis.


  • Open Access

    Parameter-Reduced YOLOv8n with GhostConv and C3Ghost for Automated Blood Cell Detection

    by Jing Yang, Bo Yang, Zhenqing Li, Yoshinori Yamaguchi, Wen Xiao

    Accurate detection of blood cells in microscopic images plays a crucial role in automated hematological analysis and clinical diagnosis. Herein, we proposed an improved YOLOv8n-based model for efficient and precise detection of red blood cells (RBCs), white blood cells (WBCs), and platelets in the BCCD dataset. The baseline YOLOv8n framework was enhanced by integrating GhostConv and C3Ghost modules to reduce model complexity while maintaining high detection performance. A series of ablation experiments were conducted to evaluate the individual and combined effects of these modules on model accuracy and computational efficiency. Experimental results demonstrated that the baseline model achieved an mAP@0.5 of 0.9043 with 3.01 M parameters. After incorporating GhostConv, the model maintained comparable accuracy (mAP@0.5 = 0.9040) with a reduction in parameters to 2.73 M. The C3Ghost integration further decreased parameters to 1.99 M with an mAP@0.5 of 0.8973. The combined model achieved an optimal balance between accuracy (mAP@0.5 = 0.9001) and compactness (1.71 M parameters). Results indicate that the improved YOLOv8n can effectively enhance detection efficiency without sacrificing precision. The proposed lightweight detection framework provides a promising solution for real-time blood cell analysis. Its high accuracy, reduced computational load, and strong generalization ability make it suitable for integration into automated laboratory systems, facilitating rapid and intelligent medical diagnostics in hematology and related biomedical applications.


  • Open Access

    Automated Detection of Parasitic Elements in Veterinary Fecal Samples Using a Deep Learning-Based Object Detection Framework

    by Jing Yang, Bo Yang, Qingxiang You, Zhenqing Li, Yoshinori Yamaguchi

    Parasitic infections in veterinary medicine are commonly diagnosed through microscopic examination of fecal samples, yet traditional manual methods are labor-intensive and subject to diagnostic variability. This study investigates YOLOv8 for automated identification of parasitic elements in fecal microscopy images. Six parasitic taxa were analyzed at 1000×, 2500×, and 10,000× magnifications: Spirometra eggs, Dipylidium egg packets, hookworm eggs, Ascaris eggs, Giardia cysts, and Trichomonas trophozoites. The dataset comprised 326 images with 3710 annotated objects, split at the sample level into training (70%), validation (15%), and testing (15%) sets. The YOLOv8n model achieved mean average precision (mAP@0.5) of 0.982 ± 0.015 across 5-fold cross-validation. Per-class AP exceeded 0.97 for five taxa, with Trichomonas achieving 0.952. Inference time averaged under 60 ms per image on a standard CPU. These results demonstrate that YOLOv8 provides accurate and efficient detection of diverse parasitic elements, supporting its potential as a clinical screening tool.

  • Open Access

    A Brief Review on the Analysis of dsDNA, RNA, Amino Acids and Bacteria by Capillary Electrophoresis

    by Yuan Zeng, Ping Wang, Bo Yang, Yuqing Xu, Yueqing Wang, Zhenqing Li, Yoshinori Yamaguchi

    Capillary electrophoresis (CE) is an effective tool for the analysis of many biocomponents, such as dsDNA, RNA, amino acids and bacteria, which are extremely important not only in research work but also in numerous practical applications. However, there are many factors that affect the separation performance, including the polymers inside the capillary, the electric field strength, the capillary coating and the effective length of the capillary. So far, various CE techniques have been developed to increase the resolution, sample volume consumption and limit of detection. To better understand the development of techniques for the separation of these biomolecules by CE, this review provides a comprehensive summary of polymers (e.g., polyvinylpyrrolidone, hydroxyethyl cellulose and polyethylene glycol), optimization methods, capillary coating methods, technological advancement of microchips for CE and the limitation of detection proposed by different groups worldwide. We also discuss the challenges and future directions associated with CE technology.


  • Open Access

    High-Resolution Analysis of DNA Electrophoretic Separations via Digital Image Processing

    by Jing Yang, Tengfei Zhang, Bo Yang, Jiahe Liu, Zhenqing Li, Yoshinori Yamaguchi

    Compared with capillary electrophoresis (CE), gel electrophoresis (GE) is a traditional method for the analysis of nucleic acids because of its low cost, although the operation process is complicated. The electropherogram from CE can offer more information (e.g., DNA size and its concentration) for researchers. Based on the self-built integrated biochip GE system, we proposed a computational method that converts conventional agarose GE images into CE-like fluorescence profiles for enhanced DNA analysis. The gel images were processed using an image-based algorithm involving median filtering to remove background noise and pixel-wise intensity summation along the migration axis to generate one-dimensional records of electrophoretic separations. Each DNA band in the gel was thereby transformed into a distinct fluorescence peak, reflecting its migration distance and relative intensity. To further enhance resolution and peak separation, Gaussian modeling was applied to fit the fluorescence intensity distribution, providing smoother and more distinguishable spectral peaks. To validate the method, three periodontal pathogens—Porphyromonas gingivalis (P.g), Treponema denticola (T.d), and Tannerella forsythia (T.f)—were amplified using PCR and analyzed by gel electrophoresis. The method successfully identified distinct electrophoretic patterns for the three pathogens by using a 50 bp DNA ladder as an internal calibration reference. The results demonstrate that image-based reconstruction of electrophoretic data provides a reliable, quantitative, and visually interpretable representation of DNA migration, comparable to CE output. This approach bridges a gap between traditional GE and modern capillary systems, allowing for the semi-quantitative analysis of DNA fragments without specialized CE instrument. The proposed method offers a valuable analysis method for the separation of DNA, RNA, protein and polypeptides.


  • Open Access

    Development of a Low-Cost and Easy-Assembly Capillary Electrophoresis System for Separation of DNA

    by Jiawen Li, Shuaiqiang Fan, Jiandong Zhu, Bo Yang, Zhenqing Li, Dawei Zhang, Yoshinori Yamaguchi

    Capillary electrophoresis based on laser-induced fluorescence (CE-LIF) plays an important role in the analysis of nucleic acids. However, the commercial CE-LIF is not only quite expensive but also inflexible, thus hindering its widespread use in the lab. Herein, we proposed a compact, low-cost, and flexible CE-LIF system. We also investigated its stability by separating the DNA ladders. Experiments demonstrated that the relative standard error of the relative fluorescence intensity and migration time was lower than 6.2% and 1.1%, respectively. The aperture size of the light source illuminating the capillary can affect the separation performance. Smaller apertures offer higher resolution length for the adjacent DNA fragments but may reduce the number of theoretical plates. Various fluorescent dyes (e.g., SYBR Green I, Gel Green, EvaGreen) can be employed in the self-built system. The limit of detection of dsDNA was as low as 0.05 ng/μL. The working range for DNA was 0.05 ng/μL~10 ng/μL. Finally, we have successfully separated the PCR products of the target gene of Porphyromonas gingivalis and Candida albicans in the home-built CE system. Such a robust CE-LIF system is easy to assemble in the lab. The total cost of the assembled CE system did not exceed 1100 USD. We believe this work can advance the application of CE and hope it will facilitate the easy assembly of flexible CE instruments in labs.