Ruikun Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ruikun Chen has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Jian Gao
State Key Laboratory of Precision Electronic Manufacturing Technology and Equipment, School of Electromechanical Engineering, Guangdong University of Technology, Guangzhou 510006, China
1 shared publication - Junwen Tan
State Key Laboratory of Precision Electronic Manufacturing Equipment and Technology, Guangdong University of Technology, Guangzhou, China
1 shared publication - Lanyu Zhang
State Key Laboratory of Precision Electronic Manufacturing Technology and Equipment, School of Electromechanical Engineering, Guangdong University of Technology, Guangzhou 510006, China
1 shared publication - Zhuojun Zheng
Guangdong University of Technology
1 shared publication
Latest Publications
- 17 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-9
Composite Phase-Shifting and Height Fusion Algorithm With Vibration-Robust in White Light Interferometry
White light interferometry is commonly illuminated using stable and long-lasting white LEDs. However, the measurement process is susceptible to the spectral effects of LEDs and environmental vibrations, which will reduce its reconstruction accuracy. This paper proposes a composite phase-shifting and height fusion algorithm to rectify the spectral distortions caused by LED light sources and minimize vibration impact by correcting errors arising from the special spectral effects in phase-shifting interferometry. Through the composite phase-shifting algorithm, this paper constructs a composite Gaussian phase shift model based on the dual-peak spectral characteristics of LED light sources to extract phase information. Then, a height fusion algorithm is presented to suppress the impact of vibration in the measuring process. This algorithm proves that the height error of the phase-shifting method has the characteristic of normal distribution, and thus lays a theoretical basis for its average calculation of random error suppression. Through plane measurement simulations and standard step height measurement experiments, the proposed method was validated consistently with high measurement accuracy and stability under various degrees of vibration interference. Compared with other methods, the proposed method can reduce the impact of LED dual-peak spectral and dynamic vibration interference on the measurements, and thus significantly enhance 3D reconstruction accuracy for white light interferometric measurement.
- 17 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-9
Composite Phase-Shifting and Height Fusion Algorithm With Vibration-Robust in White Light Interferometry
White light interferometry is commonly illuminated using stable and long-lasting white LEDs. However, the measurement process is susceptible to the spectral effects of LEDs and environmental vibrations, which will reduce its reconstruction accuracy. This paper proposes a composite phase-shifting and height fusion algorithm to rectify the spectral distortions caused by LED light sources and minimize vibration impact by correcting errors arising from the special spectral effects in phase-shifting interferometry. Through the composite phase-shifting algorithm, this paper constructs a composite Gaussian phase shift model based on the dual-peak spectral characteristics of LED light sources to extract phase information. Then, a height fusion algorithm is presented to suppress the impact of vibration in the measuring process. This algorithm proves that the height error of the phase-shifting method has the characteristic of normal distribution, and thus lays a theoretical basis for its average calculation of random error suppression. Through plane measurement simulations and standard step height measurement experiments, the proposed method was validated consistently with high measurement accuracy and stability under various degrees of vibration interference. Compared with other methods, the proposed method can reduce the impact of LED dual-peak spectral and dynamic vibration interference on the measurements, and thus significantly enhance 3D reconstruction accuracy for white light interferometric measurement.