    Single-Node Power Demand During AI Training: Measurements on an 8-GPU NVIDIA H100 System

    by Imran Latif, Alex C. Newkirk, Matthew R. Carbone, Arslan Munir, Yuewei Lin, Jonathan Koomey, Xi Yu, Zhihua Dong

    The expansion of artificial intelligence (AI) applications has driven substantial investment in computational infrastructure, especially by cloud computing providers. Quantifying the energy footprint of this infrastructure requires models parameterized by the power demand of AI hardware during training. In this work, we measured the instantaneous power draw of an 8-GPU NVIDIA H100 HGX node during the training of open-source image classifier (ResNet) and large-language models (Llama2-13b).We characterize power demand for a single node configuration, providing foundational data for future multi-node studies. The maximum observed power draw was approximately 8.4 kW, 18% lower than the manufacturer-rated 10.2 kW, even with GPUs near full utilization. Holding model architecture constant, increasing batch size from 512 to 4096 images for ResNet reduced total training energy consumption by a factor of 4. These findings can inform capacity planning for data center operators and energy use estimates by researchers. Future work will investigate the impact of cooling technology and carbon-aware scheduling on AI workload energy consumption.


  • Advancing Sustainability in Data Centers: Evaluation of Hybrid Air/Liquid Cooling Schemes for IT Payload Using Sea Water

    by Imran Latif, Muhammad Mubashar Ashraf, Umaima Haider, Gemma Reeves, Alexandrina Untaroiu, Fabio ´ Coelho, Denis Browne

    The growth in cloud computing, big data, AI and -performance computing (HPC) necessitate the deployment of additional data centers (DC's) with high energy demands. The unprecedented increase in the Thermal Design Power (TDP) of the computing chips will require innovative cooling techniques. Furthermore, DC's are increasingly limited in their ability to add powerful GPU servers by power capacity constraints. As cooling energy use accounts for up to 40% of DC energy consumption, creative cooling solutions are urgently needed to allow deployment of additional servers, enhance sustainability and increase energy efficiency of DC's. The information in this study is provided from Start Campus' Sines facility supported by Alfa Laval for the heat exchanger and CO2 emission calculations.The study evaluates the performance and sustainability impact of various data center cooling strategies including an air-only deployment and a subsequent hybrid air/water cooling solution all utilizing sea water as the cooling source. We evaluate scenarios from 3MW to 15+1MW of IT load in 3MW increments which correspond to the size of heat exchangers used in the Start Campus' modular system design. This study also evaluates the CO2 emissions compared to a conventional chiller system for all the presented scenarios. Results indicate that the effective use of the sea water cooled system combined with liquid cooled systems improve the efficiency of the DC, plays a role in decreasing the CO2 emissions and supports in achieving sustainability goals.