Richard Pesti
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Richard Pesti has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Akos Odry
Department of Mechatronics and Automation, Faculty of Engineering, University of Szeged, Szeged, Hungary
6 shared publications - Peter Sarcevic
Department of Mechatronics and Automation, Faculty of Engineering, University of Szeged, Szeged, Hungary
6 shared publications - Dominik Csík
Szegedi Tudomanyegyetem
5 shared publications - József Sárosi
Department of Mechatronics and Automation, Faculty of Engineering, University of Szeged, 6725 Szeged, Hungary
2 shared publications - Istvan Kecskes
Institute of Informatics, University of Dunaújváros, Dunaújváros, Hungary
1 shared publication - Juvenal Rodríguez-Reséndiz
Faculty of Engineering, Autonomous University of Queretaro, Santiago de Querétaro 76010, México
1 shared publication
Latest Publications
- 16 March 2026
- Published by University of Szeged in Jelenkori Társadalmi és Gazdasági Folyamatok
- Vol. 21 (1)
Giroszkóp kalibrációs módszerek
A MEMS alapú háromtengelyes giroszkópok az inerciális mérőegységek egy részét képezik, melyek kulcsszerepet játszanak számos modern technológiai alkalmazásban, például a robotikában, a navigációs rendszerekben, a repüléstechnikában, a mobilkészülékekben és a szórakoztatóiparban. A giroszkópok pontos működése elengedhetetlen a helyzet- és iránymeghatározás pontosságának biztosításához. A gyártásból eredő eltérések, valamint a külső környezeti hatások miatt a giroszkóp mérései idővel eltérhetnek a valódi értéktől, ami pontatlan mérési adatokat eredményezhet. A giroszkóp kalibráció célja, hogy korrigálja ezeket az eltéréseket, és ezáltal pontosítsa a méréseket. A kalibráció során meghatározzák a giroszkóp nullponti eltolódását (bias), a skálázási tényezőt (scale-factor) és az érzékelő tengelyek közötti kereszthatásokat. A kalibráció történhet statikus vagy dinamikus módszerrel. A giroszkópok kalibrációjához széles körben alkalmazott algoritmusok közé tartozik a Kálmán-szűrő, a részecske-raj optimalizáció, a genetikus algoritmus, valamint a mesterséges neurális hálózatok. A pontosan kalibrált giroszkópok javítják a helymeghatározás és mozgáskövetés pontosságát, növelik a rendszer megbízhatóságát. A kalibráció tehát elengedhetetlen a giroszkópokon alapuló rendszerek megbízható és pontos működéséhez.
- 16 March 2026
- Published by University of Szeged in Jelenkori Társadalmi és Gazdasági Folyamatok
- Vol. 21 (1)
Giroszkóp kalibrációs módszerek
A MEMS alapú háromtengelyes giroszkópok az inerciális mérőegységek egy részét képezik, melyek kulcsszerepet játszanak számos modern technológiai alkalmazásban, például a robotikában, a navigációs rendszerekben, a repüléstechnikában, a mobilkészülékekben és a szórakoztatóiparban. A giroszkópok pontos működése elengedhetetlen a helyzet- és iránymeghatározás pontosságának biztosításához. A gyártásból eredő eltérések, valamint a külső környezeti hatások miatt a giroszkóp mérései idővel eltérhetnek a valódi értéktől, ami pontatlan mérési adatokat eredményezhet. A giroszkóp kalibráció célja, hogy korrigálja ezeket az eltéréseket, és ezáltal pontosítsa a méréseket. A kalibráció során meghatározzák a giroszkóp nullponti eltolódását (bias), a skálázási tényezőt (scale-factor) és az érzékelő tengelyek közötti kereszthatásokat. A kalibráció történhet statikus vagy dinamikus módszerrel. A giroszkópok kalibrációjához széles körben alkalmazott algoritmusok közé tartozik a Kálmán-szűrő, a részecske-raj optimalizáció, a genetikus algoritmus, valamint a mesterséges neurális hálózatok. A pontosan kalibrált giroszkópok javítják a helymeghatározás és mozgáskövetés pontosságát, növelik a rendszer megbízhatóságát. A kalibráció tehát elengedhetetlen a giroszkópokon alapuló rendszerek megbízható és pontos működéséhez.
- 1 December 2025
- Published by University of Szeged in Jelenkori Társadalmi és Gazdasági Folyamatok
- Vol. 20 (4)
WiFi RSSI-alapú beltéri pozicionálás trilaterációval különböző referencia node konfigurációk mellett
Beltéri környezetben a közvetlen rálátás (Line-of-Sight) hiánya korlátozza a kültéri navigációs rendszerek, például a GPS alkalmazhatóságát. E kihívás kezelésére a beltéri helymeghatározás során vezeték nélküli szenzorhálózatokra lehet támaszkodni, melyek rádiókommunikációs technológiákat (pl. WiFi, Bluetooth, UWB) hasznosítanak. A pozíció becslése különböző jeltulajdonságok – úgymint a vételi jelerősség (RSSI), a jel beérkezési ideje (TOA), a beérkezési szög (AoA) vagy a csatornaállapot-információ (CSI) – alapján történik. Az elterjedt módszerek közé tartoznak a távolságalapú (pl. trilateráció) és a távolságfüggetlen (pl. fingerprinting) eljárások. Jelen kutatás egy 2,4 GHz-es WiFi RSSI-mérésen alapuló beltéri helymeghatározó rendszer fejlesztésére és kiértékelésére irányult. Egy 8 m x 12 m-es laboratóriumi térben 5 fix referenciaállomás (node) került elhelyezésre, a méréseket mobil robot végezte 20 cm-es felbontásban. A pozíciók trilaterációs algoritmussal kerültek meghatározásra, különböző node-konfigurációkban (3-5 node) elemezve az adatbázist. Az eredmények igazolták, hogy a referenciaállomások számának és elrendezésének optimalizálása jelentősen befolyásolja a pozicionálás pontosságát: három node esetén az átlagos abszolút hiba 2,41–3,86 m, négy node-dal 2,34–3,02 m, míg öt node felhasználásával a legpontosabb, 2,28 m-es átlagos abszolút hiba került elérésre. Ez a kutatás megerősíti a node-ok számának és pozíciójának kulcsszerepét a WiFi RSSI-alapú beltéri helymeghatározásban.
- 1 December 2025
- Published by University of Szeged in Jelenkori Társadalmi és Gazdasági Folyamatok
- Vol. 20 (4)
WiFi RSSI-alapú beltéri pozicionálás trilaterációval különböző referencia node konfigurációk mellett
Beltéri környezetben a közvetlen rálátás (Line-of-Sight) hiánya korlátozza a kültéri navigációs rendszerek, például a GPS alkalmazhatóságát. E kihívás kezelésére a beltéri helymeghatározás során vezeték nélküli szenzorhálózatokra lehet támaszkodni, melyek rádiókommunikációs technológiákat (pl. WiFi, Bluetooth, UWB) hasznosítanak. A pozíció becslése különböző jeltulajdonságok – úgymint a vételi jelerősség (RSSI), a jel beérkezési ideje (TOA), a beérkezési szög (AoA) vagy a csatornaállapot-információ (CSI) – alapján történik. Az elterjedt módszerek közé tartoznak a távolságalapú (pl. trilateráció) és a távolságfüggetlen (pl. fingerprinting) eljárások. Jelen kutatás egy 2,4 GHz-es WiFi RSSI-mérésen alapuló beltéri helymeghatározó rendszer fejlesztésére és kiértékelésére irányult. Egy 8 m x 12 m-es laboratóriumi térben 5 fix referenciaállomás (node) került elhelyezésre, a méréseket mobil robot végezte 20 cm-es felbontásban. A pozíciók trilaterációs algoritmussal kerültek meghatározásra, különböző node-konfigurációkban (3-5 node) elemezve az adatbázist. Az eredmények igazolták, hogy a referenciaállomások számának és elrendezésének optimalizálása jelentősen befolyásolja a pozicionálás pontosságát: három node esetén az átlagos abszolút hiba 2,41–3,86 m, négy node-dal 2,34–3,02 m, míg öt node felhasználásával a legpontosabb, 2,28 m-es átlagos abszolút hiba került elérésre. Ez a kutatás megerősíti a node-ok számának és pozíciójának kulcsszerepét a WiFi RSSI-alapú beltéri helymeghatározásban.
- Open Access
- 25 March 2025
- Published by Springer Nature in International Journal of Intelligent Robotics and Applications
- Vol. 9 (4) , 1459-1479
Artificial neural network-based MEMS accelerometer array calibration
Accurate calibration of micro-electromechanical systems (MEMS) accelerometers is crucial for enhancing the performance of low-cost inertial measurement units (IMUs). This paper introduces a novel calibration technique that leverages artificial neural networks (ANNs) combined with data from multiple IMUs to increase the accuracy of the calibration. The proposed method involves a calibrated UR robot, which enables the data acquisition of ground truth data for an effective calibration of IMUs. It enhances the calibration accuracy by utilizing the collective measurements from five IMUs within an accelerometer array. Fourteen sets of measurement data were established in dynamic environments using the robotic arm. The ANN-based approach was trained using ten datasets of dynamic measurements, where the trained model is validated against four unseen test data. The ANN-based calibration performance is evaluated by comparing it to standard methods such as ellipsoid fitting method and arithmetic averaging of the sensor outputs. Results demonstrate that the proposed method achieves superior calibration accuracy, with an improvement of 18.2% over the ellipsoid fitting technique and 23.3% over the averaging method. It also shows that fusing accelerometer measurements with Euler angles calculated from acceleration as input data for the ANN provided the best results for the calibration. The findings suggest that integrating ANN models with data fusion from multiple sensors significantly improves the calibration accuracy of MEMS accelerometers, thereby enhancing their potential for use in precise motion sensing applications.
- 25 March 2025
- Published by Springer Nature in International Journal of Intelligent Robotics and Applications
- Vol. 9 (4) , 1459-1479
Open AccessArtificial neural network-based MEMS accelerometer array calibration
Accurate calibration of micro-electromechanical systems (MEMS) accelerometers is crucial for enhancing the performance of low-cost inertial measurement units (IMUs). This paper introduces a novel calibration technique that leverages artificial neural networks (ANNs) combined with data from multiple IMUs to increase the accuracy of the calibration. The proposed method involves a calibrated UR robot, which enables the data acquisition of ground truth data for an effective calibration of IMUs. It enhances the calibration accuracy by utilizing the collective measurements from five IMUs within an accelerometer array. Fourteen sets of measurement data were established in dynamic environments using the robotic arm. The ANN-based approach was trained using ten datasets of dynamic measurements, where the trained model is validated against four unseen test data. The ANN-based calibration performance is evaluated by comparing it to standard methods such as ellipsoid fitting method and arithmetic averaging of the sensor outputs. Results demonstrate that the proposed method achieves superior calibration accuracy, with an improvement of 18.2% over the ellipsoid fitting technique and 23.3% over the averaging method. It also shows that fusing accelerometer measurements with Euler angles calculated from acceleration as input data for the ANN provided the best results for the calibration. The findings suggest that integrating ANN models with data fusion from multiple sensors significantly improves the calibration accuracy of MEMS accelerometers, thereby enhancing their potential for use in precise motion sensing applications.
- 10 March 2025
- Published by Springer Nature in International Journal of Control, Automation, and Systems
- Vol. 23 (3) , 920-934
NN-augmented EKF for Robust Orientation Estimation Based on MARG Sensors
- 10 March 2025
- Published by Springer Nature in International Journal of Control, Automation, and Systems
- Vol. 23 (3) , 920-934
NN-augmented EKF for Robust Orientation Estimation Based on MARG Sensors
- Open Access
- 4 August 2024
- Published by University of Szeged in Analecta Technica Szegedinensia
- Vol. 18 (2) , 30-37
Measurement System for the Calibration of Accelerometer Arrays
This paper addresses accelerometer array calibration, focusing on determining the errors between multiple sensors. Micro-electromechanical system (MEMS) based triaxial accelerometers, key components of Inertial Measurement Units (IMUs), are used in localization, robotics, and navigation systems. The requirements of these applications necessitate low-cost sensors, which makes MEMS IMUs a reasonable choice. However, these low-cost IMUs are significantly affected by systematic (i.e., bias, misalignment, scale-factor) and random errors. Achieving reliable sensor output depends on the precision of the executed calibration method. While traditional laboratory-based sensor calibration using specialized equipment (i.e., three-axis turntable) is accurate, it is time-consuming and costly. In contrast, in-field calibration techniques, which can be performed using a mechatronic actuator or a robotic arm, have gained popularity. These techniques involve comparing sensor measurements to established reference values. The MEMS sensors are increasingly being used in multi-sensor applications, which demands not only individual sensor error calibration but also important to determine the axis misalignment between the used sensors. During calibration process, various optimization algorithms (e.g., GA, PSO) can also be used to find the error parameters. The proposed measurement system allows for individual calibration of misalignment, bias, and scale factor of the sensor array, and eliminates between-sensor misalignment errors.
- 4 August 2024
- Published by University of Szeged in Analecta Technica Szegedinensia
- Vol. 18 (2) , 30-37
Open AccessMeasurement System for the Calibration of Accelerometer Arrays
This paper addresses accelerometer array calibration, focusing on determining the errors between multiple sensors. Micro-electromechanical system (MEMS) based triaxial accelerometers, key components of Inertial Measurement Units (IMUs), are used in localization, robotics, and navigation systems. The requirements of these applications necessitate low-cost sensors, which makes MEMS IMUs a reasonable choice. However, these low-cost IMUs are significantly affected by systematic (i.e., bias, misalignment, scale-factor) and random errors. Achieving reliable sensor output depends on the precision of the executed calibration method. While traditional laboratory-based sensor calibration using specialized equipment (i.e., three-axis turntable) is accurate, it is time-consuming and costly. In contrast, in-field calibration techniques, which can be performed using a mechatronic actuator or a robotic arm, have gained popularity. These techniques involve comparing sensor measurements to established reference values. The MEMS sensors are increasingly being used in multi-sensor applications, which demands not only individual sensor error calibration but also important to determine the axis misalignment between the used sensors. During calibration process, various optimization algorithms (e.g., GA, PSO) can also be used to find the error parameters. The proposed measurement system allows for individual calibration of misalignment, bias, and scale factor of the sensor array, and eliminates between-sensor misalignment errors.
- Open Access
- 26 July 2023
- Published by MDPI AG in Electronics
- Vol. 12 (15) , 3238
Online Outdoor Terrain Classification Algorithm for Wheeled Mobile Robots Equipped with Inertial and Magnetic Sensors
Terrain classification provides valuable information for both control and navigation algorithms of wheeled mobile robots. In this paper, a novel online outdoor terrain classification algorithm is proposed for wheeled mobile robots. The algorithm is based on only time-domain features with both low computational and low memory requirements, which are extracted from the inertial and magnetic sensor signals. Multilayer perceptron (MLP) neural networks are applied as classifiers. The algorithm is tested on a measurement database collected using a prototype measurement system for various outdoor terrain types. Different datasets were constructed based on various setups of processing window sizes, used sensor types, and robot speeds. To examine the possibilities of the three applied sensor types in the application, the features extracted from the measurement data of the different sensors were tested alone, in pairs and fused together. The algorithm is suitable to operate online on the embedded system of the mobile robot. The achieved results show that using the applied time-domain feature set the highest classification efficiencies on unknown data can be above 98%. It is also shown that the gyroscope provides higher classification rates than the widely used accelerometer. The magnetic sensor alone cannot be effectively used but fusing the data of this sensor with the data of the inertial sensors can improve the performance.
- 26 July 2023
- Published by MDPI AG in Electronics
- Vol. 12 (15) , 3238
Open AccessOnline Outdoor Terrain Classification Algorithm for Wheeled Mobile Robots Equipped with Inertial and Magnetic Sensors
Terrain classification provides valuable information for both control and navigation algorithms of wheeled mobile robots. In this paper, a novel online outdoor terrain classification algorithm is proposed for wheeled mobile robots. The algorithm is based on only time-domain features with both low computational and low memory requirements, which are extracted from the inertial and magnetic sensor signals. Multilayer perceptron (MLP) neural networks are applied as classifiers. The algorithm is tested on a measurement database collected using a prototype measurement system for various outdoor terrain types. Different datasets were constructed based on various setups of processing window sizes, used sensor types, and robot speeds. To examine the possibilities of the three applied sensor types in the application, the features extracted from the measurement data of the different sensors were tested alone, in pairs and fused together. The algorithm is suitable to operate online on the embedded system of the mobile robot. The achieved results show that using the applied time-domain feature set the highest classification efficiencies on unknown data can be above 98%. It is also shown that the gyroscope provides higher classification rates than the widely used accelerometer. The magnetic sensor alone cannot be effectively used but fusing the data of this sensor with the data of the inertial sensors can improve the performance.