Haozhe Ji
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Haozhe Ji has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Ruohui Wang
School of Physics, Northwest University, Xian, China
2 shared publications - Xueguang Qiao
Northwest University
2 shared publications - Dan Su
School of Physics, Northwest University, Xian, China
1 shared publication Fengyi Chen
1 shared publicationJicheng Yang
1 shared publicationMinghui He
School of Physics, Northwest University and Engineering Research Center of Optical Fiber Well Logging Technology for Oil and Gas Resources, Universities of Shaanxi Province, Xian, China
1 shared publication
Latest Publications
- 28 August 2026
- Published by Elsevier in Measurement
- Vol. 290
Bridge vibration monitoring based on a novel extrinsic optic fiber Fabry–Perot accelerometer
- 28 August 2026
- Published by Elsevier in Measurement
- Vol. 290
Bridge vibration monitoring based on a novel extrinsic optic fiber Fabry–Perot accelerometer
- 17 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (6) , 9641-9646
Two-Phase Flow Holdup Meter Using a Double-FBG Viscous Force Sensor
In this paper, we propose a double-FBG-based sensor for measuring the holdup of two-phase flow. The sensor consists of a double-FBG and a flexible sheet which has tangential movement in the fluid. The tangential movement can be measured by FBG wavelength shift. The test results show that the flow rate, holdup and temperature are related to the FBG wavelength shift. This means that the holdup can be calculated by the FBG wavelength signal when the flow rate and temperature are known. A double-FBG uses differential amplification to enhance sensitivity and eliminate self-temperature effect. The flexible sheet,with a thickness of 0.1 mm and a size of 10 mm×20 mm, reduces the normal force and increases the tangential force. The sensor was verified to measure the holdup of different holdup of oil-water mixtures in the pipeline, with an error of 6.69%- 12.67%. The measurements introduce a novel principle for two-phase flow sensing, proposing possibilities for the advancement of optical fiber holdup sensors.
- 17 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (6) , 9641-9646
Two-Phase Flow Holdup Meter Using a Double-FBG Viscous Force Sensor
In this paper, we propose a double-FBG-based sensor for measuring the holdup of two-phase flow. The sensor consists of a double-FBG and a flexible sheet which has tangential movement in the fluid. The tangential movement can be measured by FBG wavelength shift. The test results show that the flow rate, holdup and temperature are related to the FBG wavelength shift. This means that the holdup can be calculated by the FBG wavelength signal when the flow rate and temperature are known. A double-FBG uses differential amplification to enhance sensitivity and eliminate self-temperature effect. The flexible sheet,with a thickness of 0.1 mm and a size of 10 mm×20 mm, reduces the normal force and increases the tangential force. The sensor was verified to measure the holdup of different holdup of oil-water mixtures in the pipeline, with an error of 6.69%- 12.67%. The measurements introduce a novel principle for two-phase flow sensing, proposing possibilities for the advancement of optical fiber holdup sensors.