Qi Lan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Qi Lan has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Haoran Zhang
Shanghai Jiao Tong University
7 shared publications Jianlong Yang
7 shared publicationsWeiyi Zhang
5 shared publicationsChengfu Gu
3 shared publicationsXipeng Shen
3 shared publications- Chang Liu
Shanghai Jiao Tong University
2 shared publications
Latest Publications
- 26 October 2026
- Published by Optica Publishing Group in Optics Express
- Vol. 34 (22) , 42139
Robust OCT-based weld-depth estimation in laser welding using spatial-temporal context and axial evidence
Accurate weld depth estimation is essential for laser welding monitoring and quality control. Optical coherence tomography (OCT) provides depth-resolved in situ sensing of keyhole dynamics, but reliable weld depth extraction remains challenging because OCT signals are often degraded by keyhole instability, spatter scattering, multiple reflections, and signal attenuation. Existing signal-processing methods and spatial learning models are prone to tracking errors when local boundary evidence becomes ambiguous. To address this problem, we propose a spatiotemporal context-guided axial evidence retrieval framework for robust OCT-based weld-depth estimation under the evaluated degraded-input conditions. The method combines spatial morphology, global-temporal context, context-guided axial evidence retrieval, and structural regularization to estimate continuous weld-depth trajectories from degraded OCT B-scans. Hann-weighted fusion is used to reconstruct full-length depth profiles from overlapping windows. On 21 labeled B-scans, the method achieves an MAE of 106.548 µ m, RMSE of 141.168 µ m, R 2 of 0.9738, and Pearson correlation of 0.9911. Under frozen OCT-only quality strata, Ours achieves the lowest Low-Q MAE (10.875 px) and Low-Q/High-Q ratio (1.484) among six models. On 27 unlabeled B-scans, it yields the lowest B-scan-TV (4.223) and curvature (2.779), and the second-lowest Jump-Ratio (0.784) among the evaluated methods, demonstrating the advantage of trajectory continuity rather than absolute depth accuracy. These results demonstrate the potential of spatiotemporal context modeling and axial evidence retrieval for robust in-situ OCT-based weld-depth monitoring in laser welding
- 26 October 2026
- Published by Optica Publishing Group in Optics Express
- Vol. 34 (22) , 42139
Robust OCT-based weld-depth estimation in laser welding using spatial-temporal context and axial evidence
Accurate weld depth estimation is essential for laser welding monitoring and quality control. Optical coherence tomography (OCT) provides depth-resolved in situ sensing of keyhole dynamics, but reliable weld depth extraction remains challenging because OCT signals are often degraded by keyhole instability, spatter scattering, multiple reflections, and signal attenuation. Existing signal-processing methods and spatial learning models are prone to tracking errors when local boundary evidence becomes ambiguous. To address this problem, we propose a spatiotemporal context-guided axial evidence retrieval framework for robust OCT-based weld-depth estimation under the evaluated degraded-input conditions. The method combines spatial morphology, global-temporal context, context-guided axial evidence retrieval, and structural regularization to estimate continuous weld-depth trajectories from degraded OCT B-scans. Hann-weighted fusion is used to reconstruct full-length depth profiles from overlapping windows. On 21 labeled B-scans, the method achieves an MAE of 106.548 µ m, RMSE of 141.168 µ m, R 2 of 0.9738, and Pearson correlation of 0.9911. Under frozen OCT-only quality strata, Ours achieves the lowest Low-Q MAE (10.875 px) and Low-Q/High-Q ratio (1.484) among six models. On 27 unlabeled B-scans, it yields the lowest B-scan-TV (4.223) and curvature (2.779), and the second-lowest Jump-Ratio (0.784) among the evaluated methods, demonstrating the advantage of trajectory continuity rather than absolute depth accuracy. These results demonstrate the potential of spatiotemporal context modeling and axial evidence retrieval for robust in-situ OCT-based weld-depth monitoring in laser welding
- 7 May 2026
- Published by Optica Publishing Group in Optica
- Vol. 13 (5) , 884
Deformation-encoded light-field transduction enables 6-DoF optical force sensing in a 1.7 mm footprint
Comprehensive six-degree-of-freedom (6-DoF) force and torque sensing is essential for robotic manipulation, micromanufacturing, and minimally invasive intervention, yet existing sensors remain limited by bulky size, complex fabrication, and high system cost. Here we report, to the best of our knowledge, the smallest 6-DoF optical force–torque sensor, featuring a footprint of only 1.7 mm. The device employs a deformation-encoded light-field transduction mechanism that converts external wrenches into spatially distributed optical responses within a coherent fiber bundle, enabling all six components to be inferred through a single optical channel. Finite-element analysis and pixel-space Jacobian analysis reveal that the optical responses span the full six-dimensional wrench space but exhibit moderate ill-conditioning due to structural coupling at the miniature scale. To address this issue, we introduce a latent-diffusion-based generative self-calibration framework that synthesizes physically consistent optical responses and enables data-efficient learning of the nonlinear mapping between light fields and mechanical loads. The system achieves highly linear, repeatable, and low-hysteresis 6-DoF measurements, remains robust under temperature and bending variations, and provides real-time force and torque feedback in phantom and in-vivo-simulated palpation. These results establish an all-optical platform that combines deformation-encoded sensing with generative calibration, paving the way toward compact and low-cost force perception for robotic and biomedical systems.
- 7 May 2026
- Published by Optica Publishing Group in Optica
- Vol. 13 (5) , 884
Deformation-encoded light-field transduction enables 6-DoF optical force sensing in a 1.7 mm footprint
Comprehensive six-degree-of-freedom (6-DoF) force and torque sensing is essential for robotic manipulation, micromanufacturing, and minimally invasive intervention, yet existing sensors remain limited by bulky size, complex fabrication, and high system cost. Here we report, to the best of our knowledge, the smallest 6-DoF optical force–torque sensor, featuring a footprint of only 1.7 mm. The device employs a deformation-encoded light-field transduction mechanism that converts external wrenches into spatially distributed optical responses within a coherent fiber bundle, enabling all six components to be inferred through a single optical channel. Finite-element analysis and pixel-space Jacobian analysis reveal that the optical responses span the full six-dimensional wrench space but exhibit moderate ill-conditioning due to structural coupling at the miniature scale. To address this issue, we introduce a latent-diffusion-based generative self-calibration framework that synthesizes physically consistent optical responses and enables data-efficient learning of the nonlinear mapping between light fields and mechanical loads. The system achieves highly linear, repeatable, and low-hysteresis 6-DoF measurements, remains robust under temperature and bending variations, and provides real-time force and torque feedback in phantom and in-vivo-simulated palpation. These results establish an all-optical platform that combines deformation-encoded sensing with generative calibration, paving the way toward compact and low-cost force perception for robotic and biomedical systems.
- 9 February 2026
- Published by Optica Publishing Group in Optics Letters
- Vol. 51 (4) , 989-992
Optical active perception with 3D Gaussian splatting enables autonomous instrument insertion in robotic vitreoretinal surgery
We present an optical active perception framework that enables autonomous instrument insertion through a trocar using robot-guided multi-view imaging. A low-cost RGB-D camera provides depth-guided viewpoint planning, while 3D Gaussian Splatting (3DGS) reconstructs a high-resolution trocar model from sparse multi-view RGB images with submillimeter fidelity, overcoming the practical limitations of commercial 3D optical sensing systems, such as stereo and structured-light cameras, in this constrained surgical scenario. Integrated with a 6-DOF robotic arm, the system estimates the trocar pose and aligns the instrument for insertion. Experiments on static and motion-simulated ex vivo porcine eyes achieve consistent submillimeter positional accuracy and angular accuracy on the order of a few degrees, sufficient for safe insertion given the narrow trocar clearance. These results establish the potential of 3DGS-based optical active perception for robotic microsurgical navigation.
- 9 February 2026
- Published by Optica Publishing Group in Optics Letters
- Vol. 51 (4) , 989-992
Optical active perception with 3D Gaussian splatting enables autonomous instrument insertion in robotic vitreoretinal surgery
We present an optical active perception framework that enables autonomous instrument insertion through a trocar using robot-guided multi-view imaging. A low-cost RGB-D camera provides depth-guided viewpoint planning, while 3D Gaussian Splatting (3DGS) reconstructs a high-resolution trocar model from sparse multi-view RGB images with submillimeter fidelity, overcoming the practical limitations of commercial 3D optical sensing systems, such as stereo and structured-light cameras, in this constrained surgical scenario. Integrated with a 6-DOF robotic arm, the system estimates the trocar pose and aligns the instrument for insertion. Experiments on static and motion-simulated ex vivo porcine eyes achieve consistent submillimeter positional accuracy and angular accuracy on the order of a few degrees, sufficient for safe insertion given the narrow trocar clearance. These results establish the potential of 3DGS-based optical active perception for robotic microsurgical navigation.
- 5 January 2026
- Published by Optica Publishing Group in Optics Letters
- Vol. 51 (2) , 293-296
Simultaneous ranging and force sensing on a single-mode fiber for minimally invasive interventions
We present a coaxial fiber probe that integrates optical coherence tomography ranging and fiber Bragg grating force sensing within a single-mode fiber, enabling synchronized distance–force feedback for minimally invasive interventions. A short no-core and graded-index fiber segment forms a weakly focused beam, extending the depth of focus while maintaining the probe’s miniature and intrinsically aligned design. Proof-of-concept experiments first demonstrate endoscopic palpation, where the probe distinguishes stiff inclusions from surrounding tissue, and then subretinal injection, where contact and puncture are simultaneously detected as changes in distance and force. This compact coaxial architecture provides a scalable platform for integrated optical sensing in robotic microsurgery and other precision manipulation tasks.
- 5 January 2026
- Published by Optica Publishing Group in Optics Letters
- Vol. 51 (2) , 293-296
Simultaneous ranging and force sensing on a single-mode fiber for minimally invasive interventions
We present a coaxial fiber probe that integrates optical coherence tomography ranging and fiber Bragg grating force sensing within a single-mode fiber, enabling synchronized distance–force feedback for minimally invasive interventions. A short no-core and graded-index fiber segment forms a weakly focused beam, extending the depth of focus while maintaining the probe’s miniature and intrinsically aligned design. Proof-of-concept experiments first demonstrate endoscopic palpation, where the probe distinguishes stiff inclusions from surrounding tissue, and then subretinal injection, where contact and puncture are simultaneously detected as changes in distance and force. This compact coaxial architecture provides a scalable platform for integrated optical sensing in robotic microsurgery and other precision manipulation tasks.
- 28 October 2025
- Published by Optica Publishing Group in Optics Letters
- Vol. 50 (21) , 6742-6745
Depth-enabled fiber-bundle endoscopy for in situ intraluminal robotic navigation
Three-dimensional perception is essential for intraluminal robotic navigation, where depth estimation provides geometric feedback for safe advancement. Fiber-bundle endoscopy provides sub-millimeter, flexible imaging for miniature probes but lacks reliable depth recovery due to artifacts and missing ground truth. We present a weakly supervised framework that augments fiber-bundle imaging with depth by combining domain translation, pseudo-depth supervision, and structure-aware constraints. Trained without paired labels or external sensors, the network infers depth directly from raw images and reconstructs lumen topology for inclination-angle guidance. Integrated with magnetic actuation, the method enables efficient closed-loop navigation in curved luminal phantoms, demonstrating depth-enabled fiber-bundle endoscopy for in situ robotic control.
- 28 October 2025
- Published by Optica Publishing Group in Optics Letters
- Vol. 50 (21) , 6742-6745
Depth-enabled fiber-bundle endoscopy for in situ intraluminal robotic navigation
Three-dimensional perception is essential for intraluminal robotic navigation, where depth estimation provides geometric feedback for safe advancement. Fiber-bundle endoscopy provides sub-millimeter, flexible imaging for miniature probes but lacks reliable depth recovery due to artifacts and missing ground truth. We present a weakly supervised framework that augments fiber-bundle imaging with depth by combining domain translation, pseudo-depth supervision, and structure-aware constraints. Trained without paired labels or external sensors, the network infers depth directly from raw images and reconstructs lumen topology for inclination-angle guidance. Integrated with magnetic actuation, the method enables efficient closed-loop navigation in curved luminal phantoms, demonstrating depth-enabled fiber-bundle endoscopy for in situ robotic control.
- 16 December 2024
- Published by Optica Publishing Group in Optics Letters
- Vol. 50 (1) , 45-48
OCT as both a shape sensor and a tomographic imager for large-scale freeform robotic scanning
To overcome the limitations of optical coherence tomography (OCT) in imaging large-scale freeform objects, we propose a methodological framework that utilizes OCT as both a shape sensor and a tomographic imager in robotic scanning. Our approach integrates a deep-learning-based surface detection algorithm to counter OCT artifacts and an adaptive robotic arm pose adjustment algorithm for sensing and imaging uneven objects. We demonstrate the effectiveness and superiority of our method on various objects, achieving high-resolution, large-scale tomographic imaging that adeptly manages OCT artifacts and surface irregularities. We think this work may contribute to expanding the applicability of OCT in both medical and industrial scenarios.
- 16 December 2024
- Published by Optica Publishing Group in Optics Letters
- Vol. 50 (1) , 45-48
OCT as both a shape sensor and a tomographic imager for large-scale freeform robotic scanning
To overcome the limitations of optical coherence tomography (OCT) in imaging large-scale freeform objects, we propose a methodological framework that utilizes OCT as both a shape sensor and a tomographic imager in robotic scanning. Our approach integrates a deep-learning-based surface detection algorithm to counter OCT artifacts and an adaptive robotic arm pose adjustment algorithm for sensing and imaging uneven objects. We demonstrate the effectiveness and superiority of our method on various objects, achieving high-resolution, large-scale tomographic imaging that adeptly manages OCT artifacts and surface irregularities. We think this work may contribute to expanding the applicability of OCT in both medical and industrial scenarios.
- 2 December 2024
- Published by Optica Publishing Group in Optics Letters
- Vol. 49 (24) , 6896-6899
Computer-generated holography enables high-uniformity, high-efficiency depth-of-focus extension in endoscopic OCT
Fiber-form optics extends the high-resolution tomographic imaging capabilities of optical coherence tomography (OCT) to the inside of the human body, i.e., endoscopic OCT. However, it still faces challenges due to the trade-off between probe size, resolution, and depth of focus (DOF). Here we introduce a method for extending the DOF in endoscopic OCT with high uniformity and efficiency. On the basis of multi-level diffractive optics, we leverage the multi-dimensional light-field modulation capabilities of computer-generated holography (CGH) to achieve precise control of the intensity distribution of the off-axis portion of the OCT probe light. Our method eliminates the need for an objective lens, allowing for direct fabrication at the distal facet of a single-mode fiber using femtosecond laser two-photon 3D printing. The superiority of our method has been verified through numerical simulation, beam measurement, and imaging results obtained with our home-built endoscopic OCT system.
- 2 December 2024
- Published by Optica Publishing Group in Optics Letters
- Vol. 49 (24) , 6896-6899
Computer-generated holography enables high-uniformity, high-efficiency depth-of-focus extension in endoscopic OCT
Fiber-form optics extends the high-resolution tomographic imaging capabilities of optical coherence tomography (OCT) to the inside of the human body, i.e., endoscopic OCT. However, it still faces challenges due to the trade-off between probe size, resolution, and depth of focus (DOF). Here we introduce a method for extending the DOF in endoscopic OCT with high uniformity and efficiency. On the basis of multi-level diffractive optics, we leverage the multi-dimensional light-field modulation capabilities of computer-generated holography (CGH) to achieve precise control of the intensity distribution of the off-axis portion of the OCT probe light. Our method eliminates the need for an objective lens, allowing for direct fabrication at the distal facet of a single-mode fiber using femtosecond laser two-photon 3D printing. The superiority of our method has been verified through numerical simulation, beam measurement, and imaging results obtained with our home-built endoscopic OCT system.