Xinye Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Xinye Chen has a total of 65 co-authors. Here are the top co-authors by number of shared publications:
- Ke Du
Chemical and Environmental Engineering Department, University of California at Riverside, B350 Bourns Hall, 900 University Ave, Riverside, CA 92521, USA
8 shared publications Ke Du
Department of Chemical and Environmental Engineering, University of California - Riverside , Riverside, CA , USA
4 shared publicationsRuo-Qian Wang
Department of Civil and Environmental Engineering, Rutgers, The State University of New Jersey, New Brunswick, NJ 08854, USA
3 shared publicationsAbbi Miller
Department of Biomedical Engineering Rochester Institute of Technology Rochester NY USA
2 shared publications- Blanca H. Lapizco-Encinas
Microscale Bioseparations Laboratory and Biomedical Engineering Department Rochester Institute of Technology Rochester New York USA
2 shared publications Jie Zhang
Carollo Engineers, Inc. , Seattle , Washington 98101 , United States
2 shared publications
Latest Publications
- 31 August 2026
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B
- Vol. 44 (5)
Nanosieve-enabled on-chip concentration and multiplexed detection of Raman-reporter-labeled nanocubes
To address persistent challenges in molecular detection—particularly signal variability, low analyte abundance, and poor spectral reproducibility—a portable bead-stacked nanosieve platform was engineered to enable robust on-chip Raman signal amplification using silver nanocubes (AgNCs) functionalized with Raman-active thiolated ligands. The microdevice integrates deformable elastomeric channels with magnetic bead stacking to immobilize and concentrate AgNCs within confined nanoscopic junctions, thereby generating densely packed plasmonic hot spot architectures that markedly enhance surface-enhanced Raman scattering efficiency. Time-resolved measurements revealed substantial increases in the Raman intensity for both 4-mercaptobenzoic acid (4-MBA) and 4-aminothiophenol (4-ATP), outperforming corresponding off-chip assays and maintaining stable enhancement factors over a 4 h operational window. Furthermore, the platform successfully demonstrated multiplexed sensing capability: mixed-analyte experiments containing 4-MBA, 4-ATP, and cysteamine produced clearly distinguishable spectral fingerprints, even under serial dilution and dynamically pulsed sample delivery. These results establish the bead-stacked nanosieve as a versatile and scalable diagnostic architecture capable of achieving high sensitivity and spectral fidelity under continuous-flow conditions.
- 31 August 2026
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B
- Vol. 44 (5)
Nanosieve-enabled on-chip concentration and multiplexed detection of Raman-reporter-labeled nanocubes
To address persistent challenges in molecular detection—particularly signal variability, low analyte abundance, and poor spectral reproducibility—a portable bead-stacked nanosieve platform was engineered to enable robust on-chip Raman signal amplification using silver nanocubes (AgNCs) functionalized with Raman-active thiolated ligands. The microdevice integrates deformable elastomeric channels with magnetic bead stacking to immobilize and concentrate AgNCs within confined nanoscopic junctions, thereby generating densely packed plasmonic hot spot architectures that markedly enhance surface-enhanced Raman scattering efficiency. Time-resolved measurements revealed substantial increases in the Raman intensity for both 4-mercaptobenzoic acid (4-MBA) and 4-aminothiophenol (4-ATP), outperforming corresponding off-chip assays and maintaining stable enhancement factors over a 4 h operational window. Furthermore, the platform successfully demonstrated multiplexed sensing capability: mixed-analyte experiments containing 4-MBA, 4-ATP, and cysteamine produced clearly distinguishable spectral fingerprints, even under serial dilution and dynamically pulsed sample delivery. These results establish the bead-stacked nanosieve as a versatile and scalable diagnostic architecture capable of achieving high sensitivity and spectral fidelity under continuous-flow conditions.
- 3 December 2024
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 25 (9) , 2157-2167
Sheath-enhanced concentration and on-chip detection of bacteria from an extremely low-concentration level
We develop a sheath-assisted and pneumatic-induced nano-sieve device for improved on-chip concentration and sensitive detection of Staphylococcus aureus , with a low concentration of ∼100 CFU mL −1 , under a fluorescence microscope in less than 30 min.
- 3 December 2024
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 25 (9) , 2157-2167
Sheath-enhanced concentration and on-chip detection of bacteria from an extremely low-concentration level
We develop a sheath-assisted and pneumatic-induced nano-sieve device for improved on-chip concentration and sensitive detection of Staphylococcus aureus , with a low concentration of ∼100 CFU mL −1 , under a fluorescence microscope in less than 30 min.
- Open Access
- 24 July 2024
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 30 (Supplement)
Three-Dimensional (3D) FIB-SEM Topography of Porous Particles
Focused Ion Beam-Scanning Electron Microscopy (FIB-SEM) is a sophisticated technique that etches off nanometer-thick layers from a sample while capturing images at each etching step. This approach facilitates comprehensive visualization of both internal and external features of the sample and allows for the assembly of image stacks to generate accurate 3D representations. The capability for 3D reconstruction offered by FIB-SEM is invaluable for elucidating intricate details of the subject under study [ 1]. Porous particles play pivotal roles across a spectrum of applications including dental care [ 2], drug delivery [ 3], and diagnostics [ 4], etc. Their unique morphology and porosity are paramount for their functional efficacy. Hence, there exists a pressing demand for precise and accessible methods to visualize 3D structures of porous particles. In this paper, we introduce a novel methodology reliant on 3D FIB-SEM tomography for visualizing porous silica shells. Our proposed method promises to offer novel insights into the evaluation of porous materials.
- 24 July 2024
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 30 (Supplement)
Open AccessThree-Dimensional (3D) FIB-SEM Topography of Porous Particles
Focused Ion Beam-Scanning Electron Microscopy (FIB-SEM) is a sophisticated technique that etches off nanometer-thick layers from a sample while capturing images at each etching step. This approach facilitates comprehensive visualization of both internal and external features of the sample and allows for the assembly of image stacks to generate accurate 3D representations. The capability for 3D reconstruction offered by FIB-SEM is invaluable for elucidating intricate details of the subject under study [ 1]. Porous particles play pivotal roles across a spectrum of applications including dental care [ 2], drug delivery [ 3], and diagnostics [ 4], etc. Their unique morphology and porosity are paramount for their functional efficacy. Hence, there exists a pressing demand for precise and accessible methods to visualize 3D structures of porous particles. In this paper, we introduce a novel methodology reliant on 3D FIB-SEM tomography for visualizing porous silica shells. Our proposed method promises to offer novel insights into the evaluation of porous materials.
- 13 March 2024
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12837, 48-51
Nano-sieve-based on-chip particle concentration for nucleic acid sensing
A miniatured, portable, cost-effective but powerful nano-sieve device is produced and developed for concentrating the targets at low concentrations, leading to the disease diagnostics at point-of-care (POC) settings. To achieve the efficient on-chip concentration of nanoparticles, the multi-sized micro-beads stacking is introduced to this nano-sieve system. Particularly, a flexible PDMS cap is applied to trap the micro-beads in the channel to serve as a three-dimensional filter to physically block and concentrate those nanoparticles, meanwhile allowing the buffer solution to flow through the channel. By coupling with a CRISPR-based assay, our nano-sieve device was expected to be employed for molecular biosensing applications, such as the detection of low light nanoparticles and target RNA, aiming to provide a rapid and efficient multiplexing sample processing at POC environments.
- 13 March 2024
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12837, 48-51
Nano-sieve-based on-chip particle concentration for nucleic acid sensing
A miniatured, portable, cost-effective but powerful nano-sieve device is produced and developed for concentrating the targets at low concentrations, leading to the disease diagnostics at point-of-care (POC) settings. To achieve the efficient on-chip concentration of nanoparticles, the multi-sized micro-beads stacking is introduced to this nano-sieve system. Particularly, a flexible PDMS cap is applied to trap the micro-beads in the channel to serve as a three-dimensional filter to physically block and concentrate those nanoparticles, meanwhile allowing the buffer solution to flow through the channel. By coupling with a CRISPR-based assay, our nano-sieve device was expected to be employed for molecular biosensing applications, such as the detection of low light nanoparticles and target RNA, aiming to provide a rapid and efficient multiplexing sample processing at POC environments.
- 18 October 2023
- Published by Royal Society of Chemistry (RSC) in Nanoscale Horizons
- Vol. 8 (12) , 1677-1685
Pneumatic nano-sieve for CRISPR-based detection of drug-resistant bacteria
The increasing prevalence of antibiotic-resistant bacterial infections, particularly methicillin-resistant Staphylococcus aureus (MRSA), presents a significant public health concern. Timely detection of MRSA is crucial to enable prompt medical intervention, limit its spread, and reduce antimicrobial resistance. Here, we introduce a miniaturized nano-sieve device featuring a pneumatically-regulated chamber for highly efficient MRSA purification from human plasma samples. By using packed magnetic beads as a filter and leveraging the deformability of the nano-sieve channel, we achieved an on-chip concentration factor of ∼15-fold for MRSA. We integrated this device with recombinase polymerase amplification (RPA) and clustered regularly interspaced short palindromic repeats (CRISPR)-Cas detection system, resulting in an on-chip limit of detection (LOD) of approximately 100 CFU mL−1. This developed approach provides a rapid, precise, and centrifuge-free solution suitable for point-of-care diagnostics, with the potential to significantly improve patient outcomes in resource-limited medical conditions.
- 18 October 2023
- Published by Royal Society of Chemistry (RSC) in Nanoscale Horizons
- Vol. 8 (12) , 1677-1685
Pneumatic nano-sieve for CRISPR-based detection of drug-resistant bacteria
The increasing prevalence of antibiotic-resistant bacterial infections, particularly methicillin-resistant Staphylococcus aureus (MRSA), presents a significant public health concern. Timely detection of MRSA is crucial to enable prompt medical intervention, limit its spread, and reduce antimicrobial resistance. Here, we introduce a miniaturized nano-sieve device featuring a pneumatically-regulated chamber for highly efficient MRSA purification from human plasma samples. By using packed magnetic beads as a filter and leveraging the deformability of the nano-sieve channel, we achieved an on-chip concentration factor of ∼15-fold for MRSA. We integrated this device with recombinase polymerase amplification (RPA) and clustered regularly interspaced short palindromic repeats (CRISPR)-Cas detection system, resulting in an on-chip limit of detection (LOD) of approximately 100 CFU mL−1. This developed approach provides a rapid, precise, and centrifuge-free solution suitable for point-of-care diagnostics, with the potential to significantly improve patient outcomes in resource-limited medical conditions.
- Open Access
- 8 February 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-7
Three-dimensional visualization of dentine occlusion based on FIB-SEM tomography
The occlusion of dentinal tubules has become a rapid and effective method for treating dentin hypersensitivity. Accurate evaluation of dentin occlusion is critical to illustrate the efficacy of oral care products and to optimize dental therapy in the clinics, which is limited by the conventional two-dimensional (2-D) characterization methods. Here, we demonstrate the visualization of the dentin occlusion via three-dimensional (3-D) characterization using a focused ion beam-scanning electron microscopy (FIB-SEM) tomography. Using the “Slice and View” approach, the material used for occluding dentin tubules is imaged with a very high-resolution voxel (10 nm × 10 nm × 20 nm) from 2-D SEM images and then reconstructed into a 3-D volume, which presents the mode of action of toothpaste for treating dentin hypersensitivity. Meanwhile, quantitative analysis of the depth of occlusion is successfully obtained. This work validates the feasibility of FIB-SEM tomography in the analysis of dentin occlusion within the complicated networks of dentine tubules at the nanoscale, and provides a novel approach to facilitate the research and development of oral care products.
- 8 February 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-7
Open AccessThree-dimensional visualization of dentine occlusion based on FIB-SEM tomography
The occlusion of dentinal tubules has become a rapid and effective method for treating dentin hypersensitivity. Accurate evaluation of dentin occlusion is critical to illustrate the efficacy of oral care products and to optimize dental therapy in the clinics, which is limited by the conventional two-dimensional (2-D) characterization methods. Here, we demonstrate the visualization of the dentin occlusion via three-dimensional (3-D) characterization using a focused ion beam-scanning electron microscopy (FIB-SEM) tomography. Using the “Slice and View” approach, the material used for occluding dentin tubules is imaged with a very high-resolution voxel (10 nm × 10 nm × 20 nm) from 2-D SEM images and then reconstructed into a 3-D volume, which presents the mode of action of toothpaste for treating dentin hypersensitivity. Meanwhile, quantitative analysis of the depth of occlusion is successfully obtained. This work validates the feasibility of FIB-SEM tomography in the analysis of dentin occlusion within the complicated networks of dentine tubules at the nanoscale, and provides a novel approach to facilitate the research and development of oral care products.
- 1 December 2022
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B
- Vol. 40 (6) , 063002
Pneumatic controlled nanosieve for efficient capture and release of nanoparticles
A pneumatic controlled nanosieve device is demonstrated for the efficient capture and release of 15 nm quantum dots. This device consists of a 200 nm deep glass channel and a polydimethylsiloxane-based pneumatic pressure layer to enhance target capture. The fluid motion inside the nanosieve is studied by computational fluidic dynamics (CFD) and microfluidic experiments, enabling efficient target capture with a flow rate as high as 100 μl/min. In addition, microgrooves are fabricated inside the nanosieve to create low flow rate regions, which further improves the target capture efficiency. A velocity contour plot is constructed with CFD, revealing that the flow rate is the lowest at the top and bottom of the microgrooves. This phenomenon is supported by the observed nanoparticle clusters surrounding the microgrooves. By changing the morphology and pneumatic pressure, this device will also facilitate rapid capture and release of various biomolecules.
- 1 December 2022
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B
- Vol. 40 (6) , 063002
Pneumatic controlled nanosieve for efficient capture and release of nanoparticles
A pneumatic controlled nanosieve device is demonstrated for the efficient capture and release of 15 nm quantum dots. This device consists of a 200 nm deep glass channel and a polydimethylsiloxane-based pneumatic pressure layer to enhance target capture. The fluid motion inside the nanosieve is studied by computational fluidic dynamics (CFD) and microfluidic experiments, enabling efficient target capture with a flow rate as high as 100 μl/min. In addition, microgrooves are fabricated inside the nanosieve to create low flow rate regions, which further improves the target capture efficiency. A velocity contour plot is constructed with CFD, revealing that the flow rate is the lowest at the top and bottom of the microgrooves. This phenomenon is supported by the observed nanoparticle clusters surrounding the microgrooves. By changing the morphology and pneumatic pressure, this device will also facilitate rapid capture and release of various biomolecules.
- Open Access
- 1 November 2021
- Published by Elsevier in Journal of Materials Research and Technology
- Vol. 15, 3005-3015
Improving the electrical conductivity of copper/graphene composites by reducing the interfacial impurities using spark plasma sintering diffusion bonding
- 1 November 2021
- Published by Elsevier in Journal of Materials Research and Technology
- Vol. 15, 3005-3015
Open AccessImproving the electrical conductivity of copper/graphene composites by reducing the interfacial impurities using spark plasma sintering diffusion bonding
- 21 August 2021
- Published by Elsevier in Journal of Colloid and Interface Science
- Vol. 606 (Pt 2) , 1609-1616
Understanding microbeads stacking in deformable Nano-Sieve for Efficient plasma separation and blood cell retrieval
- 21 August 2021
- Published by Elsevier in Journal of Colloid and Interface Science
- Vol. 606 (Pt 2) , 1609-1616
Understanding microbeads stacking in deformable Nano-Sieve for Efficient plasma separation and blood cell retrieval
- Open Access
- 19 February 2021
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 7 (8) , eabf6941
Suppression of dendrite growth by cross-flow in microfluidics
A cross-flow in microfluidics suppresses dendrite growth and electroconvection during electrodeposition.
- 19 February 2021
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 7 (8) , eabf6941
Open AccessSuppression of dendrite growth by cross-flow in microfluidics
A cross-flow in microfluidics suppresses dendrite growth and electroconvection during electrodeposition.