Jong Jin Moon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jong Jin Moon has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Ba Woo Ko
Department of Orthopedic Surgery, Chosun University Hospital, Gwangju 61453, Republic of Korea
1 shared publication - Gwang Chul Lee
College of Medicine, Chosun University, Gwangju 61452, Republic of Korea
1 shared publication - Hyeon Joon Lee
Ulsan University Hospital, Ulsan, Republic of Korea
1 shared publication - Hyun Bai Choi
Chosun University, Gwangju, Republic of Korea
1 shared publication
Latest Publications
- 18 March 2025
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 35 (1) , 1-6
Comparison of preoperative radiographic measurements for femoral shaft fractures: a study on canal diameter measurement methods
Purpose This study sought to determine the most reliable preoperative method for measuring canal diameter in femoral shaft fractures to optimize intramedullary nailing outcomes. Methods We retrospectively analyzed 164 patients treated with intramedullary nailing at University Hospital from October 2017 to December 2019. Each patient’s canal diameter was measured using five techniques: simple anteroposterior (AP) radiography, simple lateral radiography, AP scanogram with a scano rod, lateral scanogram with a scano rod, and computed tomography (CT). Error was calculated as preoperative measurement minus actual nail diameter. Interobserver reliability was assessed with Cohen’s Kappa coefficient and paired t tests, with subgroup analyses for isthmus fractures and osteoporosis. Results CT yielded the smallest error (−0.34 ± 0.87 mm and 0.25 ± 1.39 mm across observers), with Kappa values of 0.61–0.85 indicating substantial reliability. Only CT showed significant error differences for isthmus fractures (p < 0.05). No method differed significantly with osteoporosis (p > 0.05). Preoperative plans adjusted in 18% of scano rod cases due to discrepancies exceeding 2 mm. Conclusion CT offers the highest reliability, particularly for isthmus fractures, while scanograms outperform simple radiography, with AP views superior to lateral views. Further investigation is needed into osteoporosis effects on measurement accuracy.
- 18 March 2025
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 35 (1) , 1-6
Comparison of preoperative radiographic measurements for femoral shaft fractures: a study on canal diameter measurement methods
Purpose This study sought to determine the most reliable preoperative method for measuring canal diameter in femoral shaft fractures to optimize intramedullary nailing outcomes. Methods We retrospectively analyzed 164 patients treated with intramedullary nailing at University Hospital from October 2017 to December 2019. Each patient’s canal diameter was measured using five techniques: simple anteroposterior (AP) radiography, simple lateral radiography, AP scanogram with a scano rod, lateral scanogram with a scano rod, and computed tomography (CT). Error was calculated as preoperative measurement minus actual nail diameter. Interobserver reliability was assessed with Cohen’s Kappa coefficient and paired t tests, with subgroup analyses for isthmus fractures and osteoporosis. Results CT yielded the smallest error (−0.34 ± 0.87 mm and 0.25 ± 1.39 mm across observers), with Kappa values of 0.61–0.85 indicating substantial reliability. Only CT showed significant error differences for isthmus fractures (p < 0.05). No method differed significantly with osteoporosis (p > 0.05). Preoperative plans adjusted in 18% of scano rod cases due to discrepancies exceeding 2 mm. Conclusion CT offers the highest reliability, particularly for isthmus fractures, while scanograms outperform simple radiography, with AP views superior to lateral views. Further investigation is needed into osteoporosis effects on measurement accuracy.