Andy H. Hung
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Andy H. Hung has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Abel Bermudez
Department of Radiology, School of Medicine, Stanford University, CA 94305, USA
2 shared publications Dan Ilyin
Department of Mechanical Engineering, Stanford University, CA 94305, USA
2 shared publications- Jihyun (Luna) Hwang
Department of Chemical Engineering, Stanford University, CA 94305, USA
2 shared publications - Joseph M. DeSimone
Department of Chemical Engineering, Stanford University, Stanford, CA 94305, USA
2 shared publications - Netra Unni Rajesh
Department of Bioengineering, Stanford University, CA 94305, USA
2 shared publications - Prima Dewi Sinawang
Department of Chemical Engineering School of Engineering Stanford University Stanford CA 94305 USA
2 shared publications
Latest Publications
- Open Access
- 26 September 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 11 (39) , eadx5492
A microneedle device for rapid dermal interstitial fluid sampling
Dermal interstitial fluid (ISF) offers a promising alternative to invasive blood tests and opportunities for skin diagnostics. Progress in both the understanding and adoption of ISF tests is hindered by sampling challenges, including lengthy collection times, non-negligible failure rates, variable collection volumes, and inconsistent bioanalyte levels. The causes of many of these issues are not well understood. We demonstrate a microneedle device that is several times faster than state of the art, collecting an average of 15.5 mg of ISF in 5 minutes in humans with near-zero failure rate. This improvement was achieved by designing the spatial pressure gradient driving ISF flow. The influence of penetration depth, collection time, pressure, and age on ISF collection was elucidated, with Darcy’s law explaining multiple observations. A data-driven acceptance criterion of <1% blood contamination for ISF is proposed. The device and findings presented will empower researchers to better conduct robust studies in the development of ISF diagnostics.
- 26 September 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 11 (39) , eadx5492
Open AccessA microneedle device for rapid dermal interstitial fluid sampling
Dermal interstitial fluid (ISF) offers a promising alternative to invasive blood tests and opportunities for skin diagnostics. Progress in both the understanding and adoption of ISF tests is hindered by sampling challenges, including lengthy collection times, non-negligible failure rates, variable collection volumes, and inconsistent bioanalyte levels. The causes of many of these issues are not well understood. We demonstrate a microneedle device that is several times faster than state of the art, collecting an average of 15.5 mg of ISF in 5 minutes in humans with near-zero failure rate. This improvement was achieved by designing the spatial pressure gradient driving ISF flow. The influence of penetration depth, collection time, pressure, and age on ISF collection was elucidated, with Darcy’s law explaining multiple observations. A data-driven acceptance criterion of <1% blood contamination for ISF is proposed. The device and findings presented will empower researchers to better conduct robust studies in the development of ISF diagnostics.
- Open Access
A Microneedle Device for Rapid Dermal Interstitial Fluid Sampling
Dermal interstitial fluid (ISF) offers a promising alternative to invasive blood tests and opportunities for novel skin diagnostics. Progress in both the understanding and adoption of ISF tests is hindered by sampling challenges, including lengthy collection times, non-negligible failure rates, variable collection volumes, and inconsistent bioanalyte levels. The causes of many of these issues are not well understood. We demonstrate a microneedle device that is several times faster than state-of-the-art, collecting an average of 15.5 mg of ISF in 5 minutes in humans with near-zero failure rate. This improvement was achieved by designing the spatial pressure gradient driving ISF flow. The influence of penetration depth, collection time, pressure, and age on ISF collection was elucidated, with Darcy’s law explaining multiple observations. A data-driven acceptance criterion of <1% blood contamination for ISF is proposed. The device and findings presented will empower researchers to better conduct robust studies in the development of ISF diagnostics.
Open AccessA Microneedle Device for Rapid Dermal Interstitial Fluid Sampling
Dermal interstitial fluid (ISF) offers a promising alternative to invasive blood tests and opportunities for novel skin diagnostics. Progress in both the understanding and adoption of ISF tests is hindered by sampling challenges, including lengthy collection times, non-negligible failure rates, variable collection volumes, and inconsistent bioanalyte levels. The causes of many of these issues are not well understood. We demonstrate a microneedle device that is several times faster than state-of-the-art, collecting an average of 15.5 mg of ISF in 5 minutes in humans with near-zero failure rate. This improvement was achieved by designing the spatial pressure gradient driving ISF flow. The influence of penetration depth, collection time, pressure, and age on ISF collection was elucidated, with Darcy’s law explaining multiple observations. A data-driven acceptance criterion of <1% blood contamination for ISF is proposed. The device and findings presented will empower researchers to better conduct robust studies in the development of ISF diagnostics.