Feilong Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Feilong Liu has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Wei Liu
School of Electrical Engineering, Southwest Jiaotong University, Chengdu 611756, China
2 shared publications - Zhuoxin Yang
School of Electrical Engineering, Southwest Jiaotong University, Chengdu, China
2 shared publications Hongji Wang
School of Electrical Engineering, Southwest Jiaotong University, Chengdu, China
1 shared publication- Jianbang Niu
School of Electrical Engineering, Southwest Jiaotong University, Chengdu, China
1 shared publication Qingan Ma
School of Electrical Engineering, Southwest Jiaotong University, Chengdu, China
1 shared publicationShuangrui Yang
School of Electrical Engineering, Southwest Jiaotong University, Chengdu, China
1 shared publication
Latest Publications
- 12 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Reliability
- Vol. 75 (00189529) , 2274-2288
A Diagnosis Method of Rail-to-Earth Insulation Based on Circuit-Field Coupling Model
A rail-to-earth insulation diagnostic method is proposed for subway systems, leveraging a computationally efficient improved field-circuit coupling model (IFCM) combined with an improved Minkowski distance (IMD) metric. The model innovatively excludes rail electric field effects and relocates leakage sources to the stray current collection network (SCCN), achieving dynamic rail-to-earth resistance (RE) simulations with deviations below 5.47% compared to experimental measurements. A multi-signal fusion approach combines rail potential (RP) and SCCN polarization potential (PP), employing time-varying filtered empirical mode decomposition (TVF-EMD) denoising and IMD-based feature extraction to quantify insulation degradation. In dynamic simulations, high computational efficiency is maintained by the IFCM, which shows a relative error of 8.09% compared to CDEGS results. Rigorous metrological validation using 5,000 defect samples demonstrates 98.09% classification accuracy, with diagnostic thresholds optimized via the Youden index. Statistical bootstrapping confirms robustness, while sensitivity analyses validate performance under noise interference, with energy feedback system (EFS) in operation, and localized insulation variations.
- 12 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Reliability
- Vol. 75 (00189529) , 2274-2288
A Diagnosis Method of Rail-to-Earth Insulation Based on Circuit-Field Coupling Model
A rail-to-earth insulation diagnostic method is proposed for subway systems, leveraging a computationally efficient improved field-circuit coupling model (IFCM) combined with an improved Minkowski distance (IMD) metric. The model innovatively excludes rail electric field effects and relocates leakage sources to the stray current collection network (SCCN), achieving dynamic rail-to-earth resistance (RE) simulations with deviations below 5.47% compared to experimental measurements. A multi-signal fusion approach combines rail potential (RP) and SCCN polarization potential (PP), employing time-varying filtered empirical mode decomposition (TVF-EMD) denoising and IMD-based feature extraction to quantify insulation degradation. In dynamic simulations, high computational efficiency is maintained by the IFCM, which shows a relative error of 8.09% compared to CDEGS results. Rigorous metrological validation using 5,000 defect samples demonstrates 98.09% classification accuracy, with diagnostic thresholds optimized via the Youden index. Statistical bootstrapping confirms robustness, while sensitivity analyses validate performance under noise interference, with energy feedback system (EFS) in operation, and localized insulation variations.
- 18 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Reliability
- Vol. 74 (3) , 4194-4206
A Unified Model of DC Traction Power Supply System and Stray Current Dissipation
The problem of dc interference caused by stray currents in dc traction power supply system (DPS) is becoming increasingly serious. In order to study the interference degree of stray currents, a unified model of DPS and stray current dissipation based on the direct boundary element method (UBEM) has been established. The stray current collection network (SCCN) polarization potential is an important index to evaluate the leakage level of stray current. In this article, the relationship between SCCN polarization potential and rail-to-earth resistance (RE), train headways and longitudinal resistance of SCCN is investigated. It provides a partial theoretical basis and calculation method for stray current protection and system optimization. Field tests and CDEGS software simulations prove that UBEM is effective. The results show that UBEM is within 6.07% of the CDEGS simulation results and within 11.45% of the field test results. Taking the actual metro project in China as an example, SCCN polarization potential is only affected by local stray current. When RE>7.35 Ω·km, The average value of the SCCN polarization potential drops below 0.5 V.
- 18 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Reliability
- Vol. 74 (3) , 4194-4206
A Unified Model of DC Traction Power Supply System and Stray Current Dissipation
The problem of dc interference caused by stray currents in dc traction power supply system (DPS) is becoming increasingly serious. In order to study the interference degree of stray currents, a unified model of DPS and stray current dissipation based on the direct boundary element method (UBEM) has been established. The stray current collection network (SCCN) polarization potential is an important index to evaluate the leakage level of stray current. In this article, the relationship between SCCN polarization potential and rail-to-earth resistance (RE), train headways and longitudinal resistance of SCCN is investigated. It provides a partial theoretical basis and calculation method for stray current protection and system optimization. Field tests and CDEGS software simulations prove that UBEM is effective. The results show that UBEM is within 6.07% of the CDEGS simulation results and within 11.45% of the field test results. Taking the actual metro project in China as an example, SCCN polarization potential is only affected by local stray current. When RE>7.35 Ω·km, The average value of the SCCN polarization potential drops below 0.5 V.