Su-Min Cho
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Su-Min Cho has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Byoung-Eun Yang
Department of Oral and Maxillofacial Surgery, Hallym University Sacred Heart Hospital, Anyang 14066, Republic of Korea
2 shared publications - Hyun-Sook Han
Department of Prosthodontics, Hallym University Sacred Heart Hospital, Anyang, Republic of Korea
2 shared publications - Soo-Hwan Byun
Department of Oral and Maxillofacial Surgery, Hallym University Sacred Heart Hospital, Anyang 14066, Republic of Korea
2 shared publications - In-Young Park
Department of Artificial Intelligence and Robotics in Dentistry, Graduate School of Clinical Dentistry, Hallym University, Chuncheon 24252, Republic of Korea
1 shared publication - Lee-Kyoung Kim
Department of Artificial Intelligence and Robotics in Dentistry, Graduate School of Clinical Dentistry, Hallym University, Chuncheon 24252, Republic of Korea
1 shared publication - Lee-Kyoung Kim
Department of Prosthodontics, Hallym University Sacred Heart Hospital, Anyang, Republic of Korea
1 shared publication
Latest Publications
- Open Access
- 31 August 2026
- Published by Korean Academy of Stomatognathic Function and Occlusion in Journal of Dental Rehabilitation and Applied Science
- Vol. 42 (3) , 181-189
Comparison of marginal bone loss using different abutment engagement techniques: a clinical study
So-Yee Ahn, Soo-Hwan Byun, Su-Min Cho, Hyun-Sook Han, Byoung-Eun Yang, Lee-Kyoung Kim. J Dent Rehabil Appl Sci 2026;42:181-9. https://doi.org/10.14368/jdras.2026.42.3.181
- 31 August 2026
- Published by Korean Academy of Stomatognathic Function and Occlusion in Journal of Dental Rehabilitation and Applied Science
- Vol. 42 (3) , 181-189
Open AccessComparison of marginal bone loss using different abutment engagement techniques: a clinical study
So-Yee Ahn, Soo-Hwan Byun, Su-Min Cho, Hyun-Sook Han, Byoung-Eun Yang, Lee-Kyoung Kim. J Dent Rehabil Appl Sci 2026;42:181-9. https://doi.org/10.14368/jdras.2026.42.3.181
- Open Access
- 19 March 2025
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 16 (3) , 107
Biomechanical Evaluation of a Novel Non-Engaging Abutment and Screw in Internal Implant Systems: Comparative Fatigue and Load Testing
Dental implants rely on precise prosthetic design and biomechanical stability to ensure long-term success. This study evaluates the mechanical performance of non-engaging abutments in multi-unit combined screw- and cement-retained prostheses (CSCRP) using two internal implant systems: the BlueDiamond (BD) and AnyOne (AO) systems. Unlike conventional implant systems that utilize the same type of screw for both engaging and non-engaging abutments, the BD system employs a distinct screw design for non-engaging abutments. A total of 80 implants were tested, with 40 in each group. Mechanical testing included static compressive load and fatigue tests following ISO 14801 standards. The BD system demonstrated significantly higher compressive strength (326.32 kgf vs. 231.82 kgf, p < 0.001) and 23.4% greater fatigue strength compared to the AO system. Precision fit analysis confirmed no significant deformation, microcracks, or fractures after 5 million loading cycles. These findings suggest that the BD system’s unique screw design for non-engaging abutments contributes to improved mechanical performance and durability. Further clinical studies are needed to assess the long-term implications of this design on prosthetic stability and implant longevity.
- 19 March 2025
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 16 (3) , 107
Open AccessBiomechanical Evaluation of a Novel Non-Engaging Abutment and Screw in Internal Implant Systems: Comparative Fatigue and Load Testing
Dental implants rely on precise prosthetic design and biomechanical stability to ensure long-term success. This study evaluates the mechanical performance of non-engaging abutments in multi-unit combined screw- and cement-retained prostheses (CSCRP) using two internal implant systems: the BlueDiamond (BD) and AnyOne (AO) systems. Unlike conventional implant systems that utilize the same type of screw for both engaging and non-engaging abutments, the BD system employs a distinct screw design for non-engaging abutments. A total of 80 implants were tested, with 40 in each group. Mechanical testing included static compressive load and fatigue tests following ISO 14801 standards. The BD system demonstrated significantly higher compressive strength (326.32 kgf vs. 231.82 kgf, p < 0.001) and 23.4% greater fatigue strength compared to the AO system. Precision fit analysis confirmed no significant deformation, microcracks, or fractures after 5 million loading cycles. These findings suggest that the BD system’s unique screw design for non-engaging abutments contributes to improved mechanical performance and durability. Further clinical studies are needed to assess the long-term implications of this design on prosthetic stability and implant longevity.