SHS. A. Hertel

S. A. Hertel

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


S. A. Hertel has a total of 186 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Design studies of a pulsed quasimonoenergetic 2-keV neutron source for calibration of low threshold dark matter detectors

    by L. Chaplinsky, S. Fiorucci, C. W. Fink, M. Garcia-Sciveres, W. Guo, S. A. Hertel, J. K. Wuko, X. Li, J. Lin, R. Mahapatra, et al.

  • Characterization of aluminum microwave SQUID multiplexers for CE ν NS detection

    by J Amidei, A Armatol, C Augier, L Bailly-Salins, G Baulieu, L Bergé, J Billard, J Blé, G Brenot, G Bres, et al.

    We present the design, fabrication, and characterization of an aluminum-based six-channel microwave SQUID multiplexer ( μ MUX) prototype for transition-edge sensor readout in the Ricochet experiment. The device consists of aluminum coplanar-waveguide resonators and RF superconducting quantum interference devices with Dolan-style Al/AlO x /Al Josephson junctions. By measuring the resonator scattering parameters at a range of probe tone frequencies, powers, and flux bias points, we demonstrate agreement between the device response and existing multiplexer models. We also characterize the noise performance in both open-loop and flux-ramping modes. With a high electron mobility transistor (HEMT) amplifier, open-loop measurements yield a flux sensitivity of 1–1.5 μ Φ 0 / Hz . With flux-ramp modulation, low-frequency 1 / f noise is suppressed, and the flux sensitivity is around 3–4 μ Φ 0 / Hz , corresponding to a current sensitivity of 24–33 pA / Hz at the input coil. We further demonstrate a reduction in readout noise by incorporating a Josephson traveling-wave parametric amplifier between the μ MUX and the HEMT. This achieves an open-loop flux sensitivity of 0.3–0.6 μ Φ 0 / Hz and an effective system noise temperature below 1K. These results establish aluminum μ MUX devices as a viable and extensible readout technology for low-noise cryogenic detector arrays.

  • Spontaneous generation of athermal phonon bursts within bulk silicon causing excess noise, low energy background events, and quasiparticle poisoning in superconducting sensors

    by C. L. Chang, Y.-Y. Chang, M. Garcia-Sciveres, W. Guo, S. A. Hertel, X. Li, J. Lin, M. Lisovenko, R. Mahapatra, W. Matava, et al.

    Solid state phonon detectors used in the search for dark matter and coherent neutrino nucleus interactions (CE ν NS) require excellent energy resolution (eV-scale or below) and low backgrounds. An unknown source of phonon bursts, the low energy excess (LEE), dominates other above-threshold backgrounds and generates excess shot noise from subthreshold bursts. In this paper, we measure these phonon bursts for 12 days after cooldown in two nearly identical 1 cm2 silicon detectors that differ only in the thickness of their substrate (1 vs 4 mm thick). We find that both the channel-correlated shot noise and near-threshold shared LEE relax with time since cooldown. Additionally, both the correlated shot noise and LEE rates scale linearly with substrate thickness. When combined with previous measurements of other silicon phonon detectors with different substrate geometries and mechanical support strategies, these measurements strongly suggest that the dominant source of both above and below threshold LEE is the bulk substrate. By monitoring the relation between bias power and excess phonon shot noise, we estimate that the energy scale for subthreshold noise events is 0.68±0.38 meV. In our final dataset, we report a world-leading energy resolution of 258.5 ± 0.4 meV in the 1 mm thick detector. Simple calculations suggest that these silicon substrate phonon bursts are likely a significant source of quasiparticle poisoning in superconducting qubits operated in well shielded and vibration free environments.


  • Open Access

    Characterization of mini-CryoCube detectors from the RICOCHET experiment commissioning at the Institut Laue-Langevin

    by A. Armatol, C. Augier, L. Bailly-Salins, G. Baulieu, L. Bergé, J. Billard, J. Blé, G. Bres, J-.L. Bret, A. Broniatowski, et al.

    The experiment aims to measure the coherent elastic neutrino-nucleus scattering process from antineutrinos emitted by a research nuclear reactor operated by the Institut Laue-Langevin (Grenoble, France). This article presents a description of the experimental installation and the detector performance achieved during its commissioning with a mini-CryoCube module consisting of three 42-g germanium cryogenic calorimeters. The baseline resolutions and background levels are reported both during reactor-on and reactor-off periods and as noise mitigation techniques were improved. A baseline resolution of 40 eV electron equivalent was achieved for the ionization channel after setup improvements, and the phonon channel resolutions ranged from 50 to 80 eV of total phonon energy. In the energy region from 2 to 7 keV, a nuclear recoil rate of 14 ( 3 ) events / ( kg day keV ) is measured during the reactor-off period selecting events in coincidence with muon veto signals. This rate is in agreement with the cosmogenic neutron rate calculated from GEANT4 simulations. After the rejection of events in coincidence with signals in the muon veto detectors, a combined 90% confidence level limit on the nuclear recoil background of < 9 events / ( kg day keV ) is obtained in that energy region during the reactor-on period, which is compatible with our GEANT4 model calculation corresponding to a total rate of 5 events / ( kg day keV ) . The sensitivity of this analysis was however found to be limited by a surface event contamination which is currently being addressed by the Collaboration with upgraded detectors.


  • Low energy backgrounds and excess noise in a two-channel low-threshold calorimeter

    by R. Anthony-Petersen, C. L. Chang, Y.-Y. Chang, L. Chaplinsky, C. W. Fink, M. Garcia-Sciveres, W. Guo, S. A. Hertel, X. Li, J. Lin, et al.

    We describe observations of low energy excess (LEE) events, background events observed in all light dark matter direct detection calorimeters, and noise in a transition edge sensor based two-channel silicon athermal phonon detector with 375 meV baseline energy resolution. We measure two distinct LEE populations: “shared” multichannel events with a pulse shape consistent with substrate athermal phonon events and sub-eV events that couple nearly exclusively to a single channel with a significantly faster pulse shape. These “singles” are consistent with events occurring within the aluminum athermal phonon collection fins. Similarly, our measured detector noise is higher than the theoretical expectation. Measured noise can be split into an uncorrelated component, consistent with shot noise from small energy depositions within the athermal phonon sensor itself, and a correlated component, consistent with shot noise from energy depositions within the silicon substrate's phonon system.