CSCamille D. E. Van Speybroeck

Camille D. E. Van Speybroeck

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Camille D. E. Van Speybroeck has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Reduction of RF Heating Near Bilateral Deep Brain Stimulation Leads Using Two‐Channel RF Shimming at 3T

    by C. D. E. van Speybroeck, W. Roskamp, E. Arts, R. S. Vinke, M. van der Graaf, W. M. Brink

    The use of 3T MRI in patients with bilateral deep brain stimulation (DBS) leads is limited by safety concerns due to radiofrequency (RF) heating. A promising strategy to overcome this problem involves RF shimming using low‐specific absorption rate (SAR) calibration scans to estimate the RF‐induced currents based on image artifacts near the leads. Although clinically available two‐channel RF shimming can suppress RF heating in a single lead configuration, complete nulling is not possible when more than one lead is involved. This study aims to develop a method to minimize rather than null RF heating and optimize imaging performance during 3T MRI in a bilateral DBS lead configuration by using two‐channel RF shimming. An anthropomorphic phantom equipped with bilateral DBS leads and fiber‐optic temperature sensors was constructed. Optimal RF shim settings were determined in multiple phantom orientations using a low‐SAR calibration protocol. These settings were evaluated and compared with the quadrature mode by measuring local RF heating during a high‐SAR imaging sequence and inspecting residual image artifacts. Measured heating curves and imaging data confirmed that tailored RF shim settings minimized RF heating and image artifacts for both leads simultaneously in all orientations studied. Two‐channel RF shimming on a clinical 3T MRI scanner can thus be optimized in a bilateral DBS lead configuration to minimize RF heating and maximize imaging performance. This workflow could potentially enable a patient‐specific workflow for safe imaging in patients with bilateral DBS leads at 3T.


  • Open Access

    Towards harmonized holmium-166 SPECT image quality for dosimetry: a multi-center, multi-vendor study

    by Lovisa E. L. Westlund Gotby, Martina Stella, Camille D. E. Van Speybroeck, Daphne Lobeek, Floris H. P. van Velden, Mette K. Stam, Petra Dibbets-Schneider, Daphne M. V. de Vries-Huizing, Erik-Jan Rijkhorst, Berlinda J. de Wit-Van de Veen, et al.

    Background: Reliable dosimetry based on SPECT/CT imaging is essential to achieve personalized 166Ho-radioembolization treatment planning and evaluation. This study quantitatively evaluates multiple acquisition and reconstruction protocols for 166Ho-SPECT imaging based on data from five Dutch hospitals. We aim to recommend an imaging protocol which harmonizes 166Ho-SPECT images for reproducible and accurate dosimetry in a multi-scanner and multi-center setting. Methods: Cylindrical and NEMA IEC phantoms, filled with 166Ho-chloride, were imaged using seven SPECT/CT scanners from two vendors (GE HealthCare and Siemens Healthineers). Data were acquired with a photopeak window centered at 81 keV. Two adjacent scatter windows, and one upper scatter window at 118 keV were used for triple-energy window (TEW) and dual-energy window (DEW) scatter correction, respectively. The TEW and DEW reconstructions used vendor-specific software. Additionally, a vendor-neutral software package with Monte Carlo (MC) scatter correction (Hermes Medical Solutions) was used to study the influence of scanner hardware on the image quality. System sensitivity was measured in projection data of the cylindrical phantom. The axial uniformity in the cylindrical phantom was used to characterize the impact of the scatter correction method. The image quality was evaluated by the coefficient of variation (COV; noise), the contrast recovery coefficients (CRCs) and contrast-to-noise ratios (CNRs). Results: TEW scatter correction resulted in superior uniformity and higher CRCs compared to the DEW (CRC for the largest sphere over all scanners, mean ± SD (range): TEW 0.54 ± 0.07 (0.36–0.65), DEW 0.44 ± 0.04 (0.34–0.51)). DEW resulted in lower noise levels compared to TEW (16% lower on average). The DEW and TEW images resulted in comparable CNRs. The system sensitivities and the vendor-neutral image reconstructions demonstrated differences in hardware between the two vendors, most likely due to the characteristics of the vendor-specific medium energy collimator. Conclusion: This study demonstrates that TEW scatter correction increases the accuracy of 166Ho-SPECT images compared to DEW, and we henceforth recommend adopting this method in the clinical 166Ho-dosimetry workflow. Scanner hardware has a substantial impact on the characteristics of the acquired data, and identical reconstruction settings will therefore not automatically lead to harmonized image quality.