Zheng Qu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Zheng Qu has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Lidai Wang
Department of Biomedical Engineering, City University of Hong Kong, Kowloon, Hong Kong Special Administrative Region of China
3 shared publications Bin Ouyang
Department of Biomedical Engineering, City University of Hong Kong, Kowloon, Hong Kong Special Administrative Region of China
1 shared publication- Bin Ouyang
City University of Hong Kong
1 shared publication Cong Mai
Department of Emergency Medicine, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Southern Medical University, Guangzhou, China
1 shared publicationJiangbo Chen
Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, SAR, China
1 shared publication- Jiangbo Chen
School of Mechanical and Automotive Engineering, South China University of Technology, Guangzhou, China
1 shared publication
Latest Publications
- Open Access
- 2 May 2026
- Published by Elsevier in Photoacoustics
- Vol. 49, 100836
Nine-grid segmentation strategy for photoacoustic imaging of microcirculation oxygenation dynamics in the thenar muscle
- 2 May 2026
- Published by Elsevier in Photoacoustics
- Vol. 49, 100836
Open AccessNine-grid segmentation strategy for photoacoustic imaging of microcirculation oxygenation dynamics in the thenar muscle
- 19 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 44 (7) , 2868-2877
High Sensitivity Photoacoustic Imaging by Learning From Noisy Data
Photoacoustic imaging (PAI) is a high-resolution biomedical imaging technology for the non-invasive detection of a broad range of chromophores at multiple scales and depths. However, limited by low chromophore concentration, weak signals in deep tissue, or various noise, the signal-to-noise ratio of photoacoustic images may be compromised in many biomedical applications. Although improvements in hardware and computational methods have been made to address this problem, they have not been readily available due to either high costs or an inability to generalize across different datasets. Here, we present a self-supervised deep learning method to increase the signal-to-noise ratio of photoacoustic images using noisy data only. Because this method does not require expensive ground truth data for training, it can be easily implemented across scanning microscopic and computed tomographic data acquired with various photoacoustic imaging systems. In vivo results show that our method makes the vascular details that were completely submerged in noise become clearly visible, increases the signal-to-noise ratio by up to 12-fold, doubles the imaging depth, and enables high-contrast imaging of deep tumors. We believe this method can be readily applied to many preclinical and clinical applications.
- 19 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 44 (7) , 2868-2877
High Sensitivity Photoacoustic Imaging by Learning From Noisy Data
Photoacoustic imaging (PAI) is a high-resolution biomedical imaging technology for the non-invasive detection of a broad range of chromophores at multiple scales and depths. However, limited by low chromophore concentration, weak signals in deep tissue, or various noise, the signal-to-noise ratio of photoacoustic images may be compromised in many biomedical applications. Although improvements in hardware and computational methods have been made to address this problem, they have not been readily available due to either high costs or an inability to generalize across different datasets. Here, we present a self-supervised deep learning method to increase the signal-to-noise ratio of photoacoustic images using noisy data only. Because this method does not require expensive ground truth data for training, it can be easily implemented across scanning microscopic and computed tomographic data acquired with various photoacoustic imaging systems. In vivo results show that our method makes the vascular details that were completely submerged in noise become clearly visible, increases the signal-to-noise ratio by up to 12-fold, doubles the imaging depth, and enables high-contrast imaging of deep tumors. We believe this method can be readily applied to many preclinical and clinical applications.