Chengyan Bai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Chengyan Bai has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Chao Zhou
University of Science and Technology Beijing, Beijing, Beijing, Beijing, 100083, CHINA
1 shared publication Chengchen Deng
Key Laboratory for Biorheological Science and Technology of Ministry of Education, National Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing, 400044, China
1 shared publicationDuanqiang Xiao
College of materials science and engineering, Shandong University of Technology, Zibo, 25500, Shandong, China
1 shared publication- Guixue Wang
Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400044, China
1 shared publication Haijun Zhang
Tongji University, Shanghai, Shanghai, 200092, CHINA
1 shared publication- Haijun Zhang
Shanghai Tenth People’s Hospital, School of Medicine, Tongji University, Shanghai, China
1 shared publication
Latest Publications
- 1 November 2026
- Published by AIP Publishing in Physics of Fluids
- Vol. 38 (11)
High-G coronary hemodynamics: Effects of bifurcation anatomy and acceleration direction
Repeated high-G exposure is a health risk factor for high-performance fighter pilots, increasing the likelihood of adverse cardiovascular events. Current aviation cardiovascular research primarily focuses on overall cardiac compensation, yet coronary hemodynamics remain incompletely understood. This study aims to investigate the hemodynamic responses of left anterior descending (LAD) and left circumflex (LCx) arteries with varying bifurcation angles under high-G acceleration. Computational fluid dynamics simulations are carried out for LAD–LCx branch models under high-G conditions with varying magnitudes and directions. High-G effects have been incorporated through an acceleration body-force term and corresponding hydrostatic pressure corrections, with inlet velocity and outlet pressure adjusted for various acceleration levels. The results demonstrate a nonlinear correlation between bifurcation angles and atherosclerosis risk. Under Earth's gravity, the 85° bifurcation exhibits the highest risk in the LAD branch, associated with relatively weaker and less coherent helical flow, pronounced high-velocity core deflection, and increased low time-averaged wall-shear stress (TAWSS) exposure. Under +4 Gz condition, the risk associated with obtuse bifurcations increases markedly, accompanied by weakened helical flow and expanded low-TAWSS regions. A 30° reclined posture partially restores helical flow and reduces low-TAWSS exposure to approximately the level observed under +1 Gz. The Gx acceleration strengthens helical flow and increases high-TAWSS exposure near the bifurcation carina. This study reveals that high +Gz amplifies the adverse hemodynamic effects through changes in helical-flow intensity and wall-shear patterns, while seat recline under +Gz reduces the risk of atherosclerosis. Acceleration direction also plays a distinct role, with Gx acceleration increasing the risk of endothelial injury.
- 1 November 2026
- Published by AIP Publishing in Physics of Fluids
- Vol. 38 (11)
High-G coronary hemodynamics: Effects of bifurcation anatomy and acceleration direction
Repeated high-G exposure is a health risk factor for high-performance fighter pilots, increasing the likelihood of adverse cardiovascular events. Current aviation cardiovascular research primarily focuses on overall cardiac compensation, yet coronary hemodynamics remain incompletely understood. This study aims to investigate the hemodynamic responses of left anterior descending (LAD) and left circumflex (LCx) arteries with varying bifurcation angles under high-G acceleration. Computational fluid dynamics simulations are carried out for LAD–LCx branch models under high-G conditions with varying magnitudes and directions. High-G effects have been incorporated through an acceleration body-force term and corresponding hydrostatic pressure corrections, with inlet velocity and outlet pressure adjusted for various acceleration levels. The results demonstrate a nonlinear correlation between bifurcation angles and atherosclerosis risk. Under Earth's gravity, the 85° bifurcation exhibits the highest risk in the LAD branch, associated with relatively weaker and less coherent helical flow, pronounced high-velocity core deflection, and increased low time-averaged wall-shear stress (TAWSS) exposure. Under +4 Gz condition, the risk associated with obtuse bifurcations increases markedly, accompanied by weakened helical flow and expanded low-TAWSS regions. A 30° reclined posture partially restores helical flow and reduces low-TAWSS exposure to approximately the level observed under +1 Gz. The Gx acceleration strengthens helical flow and increases high-TAWSS exposure near the bifurcation carina. This study reveals that high +Gz amplifies the adverse hemodynamic effects through changes in helical-flow intensity and wall-shear patterns, while seat recline under +Gz reduces the risk of atherosclerosis. Acceleration direction also plays a distinct role, with Gx acceleration increasing the risk of endothelial injury.
- Top Cited PapersOpen Access
- 1 May 2026
- Published by KEAI Publishing in Bioactive Materials
- Vol. 59, 492-511
Degradation behavior and biological properties of a novel biodegradable zinc alloy biliary stent
Current biodegradable biliary stents remain inadequate for clinical demands. Zinc (Zn) alloys, exhibiting excellent mechanical properties, moderate degradation rates, and favorable biocompatibility, are potential materials for biodegradable biliary stents. In this study, trace boron (B) was added to Zn-0.8Cu alloy to enhance its mechanical properties and biocompatibility, and to investigate its suitability as biliary stent. The incorporation of 0.03 wt% boron significantly refined the grain size and introduced the bimodal organization, consequently enhancing the mechanical properties of Zn-0.8Cu alloy (As cast: yield strength, ultimate tensile strength, and elongation increased by 52.0 %, 42.5 %, and 153.8 %, respectively). Moreover, boron addition reduced the corrosion resistance of Zn-0.8Cu alloy and the surface became hydrophilic (water contact angle 70.75° ± 1.74°). In vitro evaluations revealed that the Zn-0.8Cu-0.03B alloy exhibited excellent biocompatibility and strongly inhibited the growth of Staphylococcus aureus and Escherichia coli. Finally, the Zn-0.8Cu-0.03B alloy stents maintained structural integrity in the rabbit common bile duct for 3 weeks, followed by accelerated degradation, and were completely degraded within 8 weeks. Zn-0.8Cu-0.03B alloy stents showed excellent biocompatibility in vivo, the degradation products were safely eliminated without causing biliary stricture or obstruction, and tissue hyperplasia induced by stent was effectively alleviated. In conclusion, this study expands the applications potential of Zn alloy in biomedicine and provides reference for developing new generation biodegradable biliary stents.
- 1 May 2026
- Published by KEAI Publishing in Bioactive Materials
- Vol. 59, 492-511
Top Cited PapersOpen AccessDegradation behavior and biological properties of a novel biodegradable zinc alloy biliary stent
Current biodegradable biliary stents remain inadequate for clinical demands. Zinc (Zn) alloys, exhibiting excellent mechanical properties, moderate degradation rates, and favorable biocompatibility, are potential materials for biodegradable biliary stents. In this study, trace boron (B) was added to Zn-0.8Cu alloy to enhance its mechanical properties and biocompatibility, and to investigate its suitability as biliary stent. The incorporation of 0.03 wt% boron significantly refined the grain size and introduced the bimodal organization, consequently enhancing the mechanical properties of Zn-0.8Cu alloy (As cast: yield strength, ultimate tensile strength, and elongation increased by 52.0 %, 42.5 %, and 153.8 %, respectively). Moreover, boron addition reduced the corrosion resistance of Zn-0.8Cu alloy and the surface became hydrophilic (water contact angle 70.75° ± 1.74°). In vitro evaluations revealed that the Zn-0.8Cu-0.03B alloy exhibited excellent biocompatibility and strongly inhibited the growth of Staphylococcus aureus and Escherichia coli. Finally, the Zn-0.8Cu-0.03B alloy stents maintained structural integrity in the rabbit common bile duct for 3 weeks, followed by accelerated degradation, and were completely degraded within 8 weeks. Zn-0.8Cu-0.03B alloy stents showed excellent biocompatibility in vivo, the degradation products were safely eliminated without causing biliary stricture or obstruction, and tissue hyperplasia induced by stent was effectively alleviated. In conclusion, this study expands the applications potential of Zn alloy in biomedicine and provides reference for developing new generation biodegradable biliary stents.
- 26 March 2025
- Published by IOP Publishing in Biomedical Materials
- Vol. 20 (3) , 032001
Recent advances and perspectives in bioresorbable metal coronary drug-eluting stents
Intervention without implantation has become a requirement for developing percutaneous coronary intervention for coronary heart disease. In this paper, the recent advances of three representative types of bioresorbable metal coronary drug-eluting stents (DESs) are reviewed, and the material composition, structural design, mechanical properties and degradability of iron-based, magnesium-based and zinc-based bioresorbable metal coronary DES are analyzed. The methods of regulating the radial strength and degradation rate of the coronary stents are summarized, and the in vivo/in vitro performance evaluation methods and ideal testing systems of the bioresorbable metal coronary DES are analyzed. Advances made in bioresorbable metal coronary DES, the existing shortcomings and optimization methods are proposed, and the future development direction is prospected.
- 26 March 2025
- Published by IOP Publishing in Biomedical Materials
- Vol. 20 (3) , 032001
Recent advances and perspectives in bioresorbable metal coronary drug-eluting stents
Intervention without implantation has become a requirement for developing percutaneous coronary intervention for coronary heart disease. In this paper, the recent advances of three representative types of bioresorbable metal coronary drug-eluting stents (DESs) are reviewed, and the material composition, structural design, mechanical properties and degradability of iron-based, magnesium-based and zinc-based bioresorbable metal coronary DES are analyzed. The methods of regulating the radial strength and degradation rate of the coronary stents are summarized, and the in vivo/in vitro performance evaluation methods and ideal testing systems of the bioresorbable metal coronary DES are analyzed. Advances made in bioresorbable metal coronary DES, the existing shortcomings and optimization methods are proposed, and the future development direction is prospected.