Aniello Pappalardo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Aniello Pappalardo has a total of 71 co-authors. Here are the top co-authors by number of shared publications:
- Giuseppe Gatti
Division of Cardiac Surgery, Cardio-thoracic and Vascular Department, Azienda Sanitaria Universitaria Giuliano Isontina, 34149 Trieste, Italy
4 shared publications - Demetrio Oliva
INFN Laboratori Nazionali del Sud, via S.Sofia 62, 95123 Catania, Italy
3 shared publications - Gianfranco Sinagra
Cardiovascular Department, Azienda Sanitaria Universitaria Integrata, 34149 Trieste, Italy
3 shared publications - Giuseppe Antonio Pablo Cirrone
INFN Laboratori Nazionali del Sud, via S.Sofia 62, 95123 Catania, Italy
3 shared publications - Roberto Catalano
INFN Laboratori Nazionali del Sud, Via S.Sofia 62, 95123 Catania
3 shared publications - Sahar Arjmand
Laboratori Nazionali del Sud (LNS), Istituto Nazionale di Fisica Nucleare (INFN), 95125 Catania, Italy
3 shared publications
Latest Publications
- 1 May 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (5)
Evaluation of a deuterated detector for gamma-ray beam intensity measurements
Laser-Compton scattering sources of quasi-monochromatic γ-ray beams have been in operation for over 30 years, with new facilities being under construction or proposed. To sustain a high-quality experimental physics program, continuous monitoring of these beams is essential by measuring the spectral, temporal, and spatial characteristics. In this work, we introduce a new method for determining the γ-ray beam intensity by using photodisintegration of deuterons in an active target detector approach. Measurements were performed using deuterated liquid scintillator detectors at several incident gamma energies between 4 and 13 MeV at the High Intensity γ-ray Source, Durham, USA. The results demonstrate that an instrument based on a deuterated active detector can be used to monitor the intensity of the γ-ray beam with high efficiency and operational simplicity.
- 1 May 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (5)
Evaluation of a deuterated detector for gamma-ray beam intensity measurements
Laser-Compton scattering sources of quasi-monochromatic γ-ray beams have been in operation for over 30 years, with new facilities being under construction or proposed. To sustain a high-quality experimental physics program, continuous monitoring of these beams is essential by measuring the spectral, temporal, and spatial characteristics. In this work, we introduce a new method for determining the γ-ray beam intensity by using photodisintegration of deuterons in an active target detector approach. Measurements were performed using deuterated liquid scintillator detectors at several incident gamma energies between 4 and 13 MeV at the High Intensity γ-ray Source, Durham, USA. The results demonstrate that an instrument based on a deuterated active detector can be used to monitor the intensity of the γ-ray beam with high efficiency and operational simplicity.
- 20 March 2025
- Published by Elsevier in Physica Medica
- Vol. 133, 104953
GANDALF: Generative ANsatz for DNA damage evALuation and Forecast. A neural network-based regression for estimating early DNA damage across micro-nano scales
- 20 March 2025
- Published by Elsevier in Physica Medica
- Vol. 133, 104953
GANDALF: Generative ANsatz for DNA damage evALuation and Forecast. A neural network-based regression for estimating early DNA damage across micro-nano scales
- Open Access
- 1 March 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (03) , C03035
Parametric study of voltage in plasma-discharge capillary systems: a benchmarking of experimental and simulation data
We explore the use of gas-filled plasma-discharge capillaries for laser wakefield acceleration (LWFA) by employing a hybrid system that integrates an external high-voltage source to driven an electrical discharge, generate plasma within the capillary channel before to the main laser pulse. The process enhances plasma formation, boosts operational efficiency, and maintains laser intensity over multiple Rayleigh lengths, enabling high-energy electron acceleration. The electrical discharge creates a stable, uniform plasma environment, improving beam charge, energy stability, and reducing energy spread. This uniform plasma ensures better laser coupling and mitigates instabilities, leading to improved beam quality. This method supports efficient acceleration and the production of very-high-energy electron (VHEE) pencil beams (250 MeV) in a compact, cost-effective system designed for radiobiological studies at the future I-LUCE (INFN-Laser indUCEd Radiation Production) facility at the Istituto Nazionale di Fisica Nucleare-Laboratori Nazionali del Sud (INFN-LNS) in Catania, Italy. The system aims to generate high-energy electron beams tailored for VHEE and FLASH radiotherapy (FLASH-RT) applications. In this paper, we present simulations of capillaries performed using COMSOL Multiphysics software, where plasma density is obtained as a function of the applied voltage. We analyze plasma behavior under varying voltage and compare the results with experimental data, demonstrating the model's accuracy in predicting plasma characteristics and its potential to optimize discharge conditions.
- 1 March 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (03) , C03035
Open AccessParametric study of voltage in plasma-discharge capillary systems: a benchmarking of experimental and simulation data
We explore the use of gas-filled plasma-discharge capillaries for laser wakefield acceleration (LWFA) by employing a hybrid system that integrates an external high-voltage source to driven an electrical discharge, generate plasma within the capillary channel before to the main laser pulse. The process enhances plasma formation, boosts operational efficiency, and maintains laser intensity over multiple Rayleigh lengths, enabling high-energy electron acceleration. The electrical discharge creates a stable, uniform plasma environment, improving beam charge, energy stability, and reducing energy spread. This uniform plasma ensures better laser coupling and mitigates instabilities, leading to improved beam quality. This method supports efficient acceleration and the production of very-high-energy electron (VHEE) pencil beams (250 MeV) in a compact, cost-effective system designed for radiobiological studies at the future I-LUCE (INFN-Laser indUCEd Radiation Production) facility at the Istituto Nazionale di Fisica Nucleare-Laboratori Nazionali del Sud (INFN-LNS) in Catania, Italy. The system aims to generate high-energy electron beams tailored for VHEE and FLASH radiotherapy (FLASH-RT) applications. In this paper, we present simulations of capillaries performed using COMSOL Multiphysics software, where plasma density is obtained as a function of the applied voltage. We analyze plasma behavior under varying voltage and compare the results with experimental data, demonstrating the model's accuracy in predicting plasma characteristics and its potential to optimize discharge conditions.
- 1 December 2017
- Published by Elsevier in Archives of Cardiovascular Diseases
- Vol. 110 (12) , 646-658
Is bilateral internal thoracic artery grafting a safe option for chronic dialysis patients?
- 1 December 2017
- Published by Elsevier in Archives of Cardiovascular Diseases
- Vol. 110 (12) , 646-658
Is bilateral internal thoracic artery grafting a safe option for chronic dialysis patients?
- 11 August 2017
- Published by Springer Nature in Heart and Vessels
- Vol. 33 (2) , 113-125
Double versus single source left-sided coronary revascularization using bilateral internal thoracic artery graft alone
Left-sided coronary revascularization with bilateral internal thoracic artery (BITA) graft is performed usually either with an in situ (double source) or Y-graft configuration (single source). Two hundred fifty-three (mean age, 67.1 ± 9.5 years) patients underwent isolated left-sided coronary revascularization with BITA graft alone at the present authors’ institution (2000–2015). Skeletonized BITA grafts were used either in an in situ (n = 199) or Y-graft configuration (n = 54). Forty pairs were identified with the propensity score-matching. Outcomes of the two groups were compared both in unmatched and matched series. Cardiopulmonary exercise testing was performed in five pairs of selected, asymptomatic matched patients having patent BITA grafts at coronary computed tomography angiography. BITA in situ patients had lower risk profiles than BITA Y-graft patients (median EuroSCORE II, 1.9 vs. 2.9%, p = 0.051). In-hospital mortality (5.6 vs. 0, p = 0.0093) and the rates of postoperative complications except deep sternal wound infection were higher in BITA Y-graft patients. However, these differences were not confirmed in matched groups. During the follow-up period (mean, 5.9 ± 4.3 years), between BITA in situ and BITA Y-graft matched patients, there were no differences in non-parametric estimates of freedom from cardiac death (p = 0.6), major adverse cardiac and cerebrovascular events (MACCEs, p = 0.65), and repeat coronary revascularization (p = 0.44). Adjusted risk estimates of MACCEs according to BITA configuration confirmed no superiority of the one configuration over the other (p ≥ 0.44). No significant differences were found at the cardiopulmonary exercise testing. Results of left-sided coronary revascularization with BITA graft alone are independent from BITA configuration, even after stress testing.
- 11 August 2017
- Published by Springer Nature in Heart and Vessels
- Vol. 33 (2) , 113-125
Double versus single source left-sided coronary revascularization using bilateral internal thoracic artery graft alone
Left-sided coronary revascularization with bilateral internal thoracic artery (BITA) graft is performed usually either with an in situ (double source) or Y-graft configuration (single source). Two hundred fifty-three (mean age, 67.1 ± 9.5 years) patients underwent isolated left-sided coronary revascularization with BITA graft alone at the present authors’ institution (2000–2015). Skeletonized BITA grafts were used either in an in situ (n = 199) or Y-graft configuration (n = 54). Forty pairs were identified with the propensity score-matching. Outcomes of the two groups were compared both in unmatched and matched series. Cardiopulmonary exercise testing was performed in five pairs of selected, asymptomatic matched patients having patent BITA grafts at coronary computed tomography angiography. BITA in situ patients had lower risk profiles than BITA Y-graft patients (median EuroSCORE II, 1.9 vs. 2.9%, p = 0.051). In-hospital mortality (5.6 vs. 0, p = 0.0093) and the rates of postoperative complications except deep sternal wound infection were higher in BITA Y-graft patients. However, these differences were not confirmed in matched groups. During the follow-up period (mean, 5.9 ± 4.3 years), between BITA in situ and BITA Y-graft matched patients, there were no differences in non-parametric estimates of freedom from cardiac death (p = 0.6), major adverse cardiac and cerebrovascular events (MACCEs, p = 0.65), and repeat coronary revascularization (p = 0.44). Adjusted risk estimates of MACCEs according to BITA configuration confirmed no superiority of the one configuration over the other (p ≥ 0.44). No significant differences were found at the cardiopulmonary exercise testing. Results of left-sided coronary revascularization with BITA graft alone are independent from BITA configuration, even after stress testing.
- 1 October 2015
- Published by Elsevier in The American Journal of Cardiology
- Vol. 116 (8) , 1193-1198
Outcome in Patients Having Salvage Coronary Artery Bypass Grafting
- 1 October 2015
- Published by Elsevier in The American Journal of Cardiology
- Vol. 116 (8) , 1193-1198
Outcome in Patients Having Salvage Coronary Artery Bypass Grafting